JJF 1621-2017Calibration Specification for Diagnostic Dosimeters (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for JJF 1621-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

February 28, 2017

Implementation date

May 28, 2017

Scope

JJF 1621-2017 (Calibration Specification for Diagnostic Dosimeters) is available as an English-translated PDF.

JJF 1621-2017 — This standard is applicable to the calibration of a 40 to 150 kV X-ray diagnostic level dosimeter or detector, CT dosimeter or detector.

Found what you need?

Document preview — JJF 1621-2017

National Standard of the People's Republic of China

ICS
17.240
Classification
A 58

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms and units of measurement (1)
  • 3.1 Terms (1)
  • 3.2 Units of measurement (2)
  • 4 Overview (2)
  • 5 Metrological characteristics (2)
  • 6 Calibration conditions (2)
  • 6.1 Environmental conditions (2)
  • 6.2 Measurement standards and other measuring equipment (3)
  • 6.3 Radiation field (3)
  • 7 Calibration items and calibration methods (3)
  • 7.1 Calibration items (3)
  • 7.2 Repetitive (3)
  • 7.3 Calibration factors (4)
  • 7.4 Energy response (6)
  • 7.5 Long-term stability (6)
  • 8 Calibration results (6)
  • 9 Re-school time interval (6)
  • Appendix A RQR, RQA and RQT Series Radiation (7)
  • Appendix B Diagnostic Level Dosimeter Calibration Record Recommended Format (8)
  • Appendix C Diagnostic Level Dosimeter Calibration Certificate Inside Page Format (9)
  • Appendix D Diagnostic Level Dosimeter Calibration Factor Uncertainty Evaluation Example (10)

1 Scope (1)

2 References (1)

3 Terms and units of measurement (1)

3.1 Terms (1)

3.2 Units of measurement (2)

4 Overview (2)

5 Metrological characteristics (2)

6 Calibration conditions (2)

6.1 Environmental conditions (2)

6.2 Measurement standards and other measuring equipment (3)

6.3 Radiation field (3)

7 Calibration items and calibration methods (3)

7.1 Calibration items (3)

7.2 Repetitive (3)

7.3 Calibration factors (4)

7.4 Energy response (6)

7.5 Long-term stability (6)

8 Calibration results (6)

9 Re-school time interval (6)

Appendix A RQR, RQA and RQT Series Radiation (7)

Appendix B Diagnostic Level Dosimeter Calibration Record Recommended Format (8)

Appendix C Diagnostic Level Dosimeter Calibration Certificate Inside Page Format (9)

Appendix D Diagnostic Level Dosimeter Calibration Factor Uncertainty Evaluation Example (10)

Introduction

This specification is prepared in accordance with the requirements of JJF 1071-2010 "Rules for the Preparation of National Metrological Calibration Standards" According to IEC 61674-2012 "Medical Electrical Equipment X-ray diagnostic images used in ionization chambers and/or semiconductors Sensorless dosimeter "(Medicalelectricalequipment-Dosimeters withionizationchambers) and/orsemiconductordetectorsasusedinX-raydiagnosticimaging), GB/T 19629-2005 "Medical electrical equipment X-ray diagnostic images used in the ionization chamber and/or semiconductor detector dosimeter" and IAEATRS457 "Radiation Diagnostic Dosage. Implementation Guide" (Dosimetryin DiagnosticRadiology.

AnInternationalCodeofPractice).

This specification is the first release.

Diagnostic level dosimeter calibration specification

1 Scope

This specification applies to measuring (40 to 150) kV X-ray diagnostic level dosimeters or detectors, CT dosimeters or Detector calibration.

2 reference file

This specification refers to the following documents.

GB/T 19629-2005 Medical electrical equipment X-ray diagnostic images used in the ionization chamber and/or half Conductor Detector Dosimeter IAEATRS457 Radiation Diagnostic Dosage. Implementation Guidelines (DosimetryinDiagnosticRadiology.

AnInternationalCodeofPractice) IEC 61267-2005 Medical diagnostic X-ray equipment Measurement characteristics Radiation conditions used (Medicaldi-agnosticX-rayequipment-Radiationconditionsforuseinthedetermination ofcharac-teristics IEC 61674-2012 Medical devices and/or semiconductors for use in X-ray diagnostic imaging Device dosimeter (Dyimeterswithionizationchambersand/or semiconductordetectorsasusedinX-raydiagnosticimaging) for dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.

3 terms and units of measurement 3.1 terminology 3.1.1 diagnostic level dosimeter diagnosticdosimeter Measuring the air kerma energy of the X-ray machine beam diagnosed with medical radiation by an ionization chamber or a semiconductor detector, Air ratio kinetic energy length product or air kerma rate of the device.

3.1.2 Air ratio kinetic energy length product airkermalengthproduct (PKL) for any straight line passing through the CT X-ray scanning cross section, the air kerma length is above the straight line Integration of gas kinetic energy and length product.

3.1.3 calibration factor the reference value is divided by the quotient.

3.1.4 energy response the response of the detector varies with the radiant energy.

3.1.5 non-diminished beam unattenuatedbeam an X-ray beam that strikes the subject or the mold body.

3.1.6 non-reduced beam unattenuatedbeamquality (RQR)

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

How to Download JJF 1621-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1621-2017

$379.00