Valid

JJF 1618-2017Calibration Specification for Insulating Oil Dielectric Dissipation Factor and Volume Resistivity Testers (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (14 pages)

Need quotation for your management?

Get a formal quotation for JJF 1618-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

February 28, 2017

Implementation date

May 28, 2017

Scope

JJF 1618-2017 (Calibration Specification for Insulating Oil Dielectric Dissipation Factor and Volume Resistivity Testers) is available as an English-translated PDF.

JJF 1618-2017 — This standard applies to the insulating oil dielectric loss factor and the volume resistivity tester (hereinafter referred to as oil damage meter) calibration.

Found what you need?

Document preview — JJF 1618-2017

National Standard of the People's Republic of China

ICS
17.220
Classification
A 55

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms and units of measurement (1)
  • 3.1 Dielectric Loss Factor (1)
  • 3.2 Insulation oil volume Resistivity (1)
  • 4 Overview (1)
  • 5 Metrological characteristics (2)
  • 5.1 Maximum allowable error of dielectric loss factor (2)
  • 5.2 Maximum allowable capacitance tolerance (3)
  • 5.3 Volume resistivity maximum allowable error (3)
  • 5.4 Maximum allowable temperature error (3)
  • 5.5 Maximum allowable error of high voltage supply voltage (3)
  • 6 Calibration conditions (3)
  • 6.1 Environmental conditions (3)
  • 6.2 Measurement standards and other equipment (3)
  • 7 Calibration items and calibration methods (4)
  • 7.1 Calibration items (4)
  • 7.2 Calibration method (4)
  • 8 Calibration results (7)
  • 8.1 Calibration Certificate (7)
  • 8.2 Assessment and presentation requirements for measurement uncertainty (8)
  • 9 Re-school time interval (8)
  • Appendix A Example of Calibration Uncertainty Evaluation (9)
  • Appendix B Calibrate Original Record Format (13)
  • Appendix C Calibration Certificate Inside Page Format (15)

1 Scope (1)

2 References (1)

3 Terms and units of measurement (1)

3.1 Dielectric Loss Factor (1)

3.2 Insulation oil volume Resistivity (1)

4 Overview (1)

5 Metrological characteristics (2)

5.1 Maximum allowable error of dielectric loss factor (2)

5.2 Maximum allowable capacitance tolerance (3)

5.3 Volume resistivity maximum allowable error (3)

5.4 Maximum allowable temperature error (3)

5.5 Maximum allowable error of high voltage supply voltage (3)

6 Calibration conditions (3)

6.1 Environmental conditions (3)

6.2 Measurement standards and other equipment (3)

7 Calibration items and calibration methods (4)

7.1 Calibration items (4)

7.2 Calibration method (4)

8 Calibration results (7)

8.1 Calibration Certificate (7)

8.2 Assessment and presentation requirements for measurement uncertainty (8)

9 Re-school time interval (8)

Appendix A Example of Calibration Uncertainty Evaluation (9)

Appendix B Calibrate Original Record Format (13)

Appendix C Calibration Certificate Inside Page Format (15)

Introduction

This specification is based on JJF 1071-2010 "national measurement calibration standard preparation rules", JJF 1001-2011 "pass Metrological terms and definitions ", JJF 1059.1-2012" Measurement Uncertainty Assessment and Representation ".

This specification is the first release.

Insulation oil dielectric loss factor and volume resistivity Tester calibration specification

1 Scope

This specification applies to insulating oil medium loss factor and volume resistivity tester (hereinafter referred to as oil resistance meter) calibration.

This specification does not apply to the calibration of high voltage dielectric loss factor testers and high voltage capacitive bridges.

2 reference file

This specification refers to the following documents.

JJG690-2003 high insulation resistance measuring instrument (high resistance meter) Electronic Insulation Resistance Table of JJG1005-2005 Measurement of relative permittivity, dielectric loss factor and DC resistivity of liquid insulating materials GB/T 5654-2007 High voltage test technology - Part 2. Measurement systems GB/T 16927.2-2013 GB/T 21216-2007 Test method for determination of dielectric loss factor for conductance and capacitance of insulating liquids Method for determination of resistivity of oil for electric power GB/T for dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.

3 terms and units of measurement 3.1 dielectric loss factor dielectricdissipationfactor the dielectric loss factor (tandelta) is the tangent of the loss angle.

3.2 Insulation oil volume Resistivity insulatingoilvolumeresistivity Insulation oil volume Resistivity is the size of the resistance of the liquid medium in the unit volume, in units of ohm · m.

4 Overview

The oil loss meter is the instrument that measures the dielectric loss factor and volume resistivity of the insulating oil. Including oil cups, temperature control systems, Measurement circuit (signal processing unit and signal measurement unit), AC-DC high voltage power supply, capacitance standard, volume resistance Rate measurement system.

Dielectric loss factor and capacitance measurement principle shown in Figure 1. standard circuit built-in high stability capacitor standard Cn and the standard circuit sampling resistor Rsn composition; test route by the test oil (Cx1, Rx) and the test circuit sampling power Resistance Rsx composition. Cx1 is the equivalent capacitance of the oil, Rx is the equivalent resistance of the oil to produce various losses. HV is AC high voltage source. Dielectric loss factor measurement method using positive connection method.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

How to Download JJF 1618-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1618-2017

$419.00