JJF 1616-2017Calibration Specification for Partial Discharge Testers Based Pulse Current Method (English PDF)
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for JJF 1616-2017 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
February 28, 2017
Implementation date
May 28, 2017
Scope
JJF 1616-2017 (Calibration Specification for Partial Discharge Testers Based Pulse Current Method) is available as an English-translated PDF.
JJF 1616-2017 — This standard applies to the pulse current method, measuring the frequency range of 10 kHz to 500 kHz between the partial discharge tester calibration.
Found what you need?
Document preview — JJF 1616-2017
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 55
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (III)
- 1 Scope (1)
- 2 References (1)
- 3 Terms and units of measurement (1)
- 3.1 Pulse current method partial discharge tester (1)
- 3.2 Impulse response of partial discharge tester (1)
- 3.3 Calibration pulse generator (1)
- 3.4 Apparent charge (1)
- 3.5 Pulse resolution time (1)
- 3.6 Pulse repetition rate (1)
- 3.7 Measurement Sensitivity (1)
- 3.8 Lower limit frequency f1 and upper frequency f2 (2)
- 3.9 Double pulse generator (2)
- 4 Overview (2)
- 5 Metrological characteristics (3)
- 5.1 Upper and lower cutoff frequency (3)
- 5.2 Apparent charge amplitude (3)
- 5.3 Shift Impulse Response Gain Value (3)
- 5.4 Positive and negative impulse response asymmetry (3)
- 5.5 Low repetition rate impulse response (3)
- 5.6 Pulse resolution time (3)
- 5.7 Measurement Sensitivity (3)
- 5.8 Pulse repetition rate (3)
- 5.9 Number of pulses (3)
- 5.10 Pulse acquisition capability (3)
- 5.11 Calibration pulse generator (3)
- 5.12 Safety performance (4)
- 6 Calibration conditions (4)
- 6.1 Environmental conditions (4)
- 6.2 Measurement standards and other equipment (4)
- 7 Calibration items and calibration methods (4)
- 7.1 Calibration items (4)
- 7.2 Calibration method (5)
- 8 Calibration results (9)
- 8.1 Calibration Certificate (9)
- 8.2 Uncertainty Rating (9)
- 9 Re-school time interval (9)
- Appendix A Cutoff Frequency and Apparent Charge Amplitude Measurement Uncertainty Evaluation Example (10)
- Appendix B Calibrate Original Record Format (13)
- Appendix C Calibration Certificate Inside Page Format (16)
1 Scope (1)
2 References (1)
3 Terms and units of measurement (1)
3.1 Pulse current method partial discharge tester (1)
3.2 Impulse response of partial discharge tester (1)
3.3 Calibration pulse generator (1)
3.4 Apparent charge (1)
3.5 Pulse resolution time (1)
3.6 Pulse repetition rate (1)
3.7 Measurement Sensitivity (1)
3.8 Lower limit frequency f1 and upper frequency f2 (2)
3.9 Double pulse generator (2)
4 Overview (2)
5 Metrological characteristics (3)
5.1 Upper and lower cutoff frequency (3)
5.2 Apparent charge amplitude (3)
5.3 Shift Impulse Response Gain Value (3)
5.4 Positive and negative impulse response asymmetry (3)
5.5 Low repetition rate impulse response (3)
5.6 Pulse resolution time (3)
5.7 Measurement Sensitivity (3)
5.8 Pulse repetition rate (3)
5.9 Number of pulses (3)
5.10 Pulse acquisition capability (3)
5.11 Calibration pulse generator (3)
5.12 Safety performance (4)
6 Calibration conditions (4)
6.1 Environmental conditions (4)
6.2 Measurement standards and other equipment (4)
7 Calibration items and calibration methods (4)
7.1 Calibration items (4)
7.2 Calibration method (5)
8 Calibration results (9)
8.1 Calibration Certificate (9)
8.2 Uncertainty Rating (9)
9 Re-school time interval (9)
Appendix A Cutoff Frequency and Apparent Charge Amplitude Measurement Uncertainty Evaluation Example (10)
Appendix B Calibrate Original Record Format (13)
Appendix C Calibration Certificate Inside Page Format (16)
Introduction
This specification is based on JJF 1071-2010 "national measurement calibration standard preparation rules", JJF 1001-2011 "pass Metrological terms and definitions ", JJF 1059.1-2012" measurement uncertainty assessment and representation "compiled from.
This specification is the first release.
Standard Specification for Calibration of Partial Discharge Tester for Pulsed Current
1 Scope
This specification applies to the pulsed current method, measuring the frequency range of 10kHz ~ 500kHz between the partial discharge test Calibration of the test instrument.
2 reference file
This specification refers to the following documents.
Partial discharge measurement GB/T 7354-2003 for dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.
3 terms and units of measurement GB/T 7354-2003 Definitions and the following terms and definitions apply to this specification.
3.1 pulsed current method partial discharge tester pulsecurrentmethodbasedpartialdischargetester Through the acquisition of pulse current signal to achieve electrical equipment, local discharge measurement of special equipment.
3.2 Impulse response of partial discharge tester pulseresponseofpartialdischargetester when the measuring circuit of the partial discharge tester injects the calibration pulse signal, its corresponding pulse output is displayed.
3.3 Calibration pulse generator calibratedpulsegenerator by the voltage amplitude of U0 pulse voltage generator and the injection capacitor C0 with the composition, can produce a known charge amount q0 of the pulse current generator.
3.4 apparent charge amount apparent charge [GB/T 7354-2003, definition 3.3.1] the apparent charge is equal to the specified test circuit, if in a very short period of time between the two sides of the sample the amount of readings on the measuring instrument is the same as that of the PD circuit itself. The apparent charge is usually used in the library (pC).
3.5 pulse resolution time [GB/T 7354-2003, definition 3.9.5] the shortest time between successive pulses of the same duration and the same amount of charge and the same amount of charge Interval, the amplitude of the impulse response in this time interval is not greater than 10% of the amplitude of a single pulse.
The pulse resolution time is generally inversely proportional to the bandwidth deltaf of the measurement system and is also a measure of the system.
The ability to characterize.
3.6 pulse repetition rate [GB/T 7354-2003, definition 3.3.2] the ratio of the total number of localized pulses recorded in the selected time interval to the time interval.
Note. Actually only consider the pulse above the specified amplitude or within the specified amplitude range.
3.7 Measurement sensitivity detectablesensitivity
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
How to Download JJF 1616-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1616-2017
$415.00