JJF 1613-2017Calibration Specification for Thin Film Thickness Measurement Instruments by Grazing Incidence X-Ray Reflectivity (English PDF)
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for JJF 1613-2017 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
February 28, 2017
Implementation date
May 28, 2017
Scope
JJF 1613-2017 (Calibration Specification for Thin Film Thickness Measurement Instruments by Grazing Incidence X-Ray Reflectivity) is available as an English-translated PDF.
JJF 1613-2017 — This standard is applicable to the calibration of grazing incidence X-ray reflectance film measuring instrument (hereinafter referred to as instrument).
Found what you need?
Document preview — JJF 1613-2017
National Standard of the People's Republic of China
- ICS
- 17.240
- Classification
- A 58
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (III)
- 1 Scope (1)
- 2 References (1)
- 3 Overview (1)
- 4 Metering characteristics (1)
- 4.1 Instrument 2theta angle indication error and repeatability (1)
- 4.2 Thickness measurement error (1)
- 4.3 Film thickness measurement repeatability (1)
- 5 Calibration conditions (1)
- 5.1 Environmental conditions (1)
- 5.2 Measurement standards and other equipment (2)
- 6 Calibration items and calibration methods (2)
- 6.1 Calibration items (2)
- 6.2 Calibration method (2)
- 7 Calibration results (3)
- 8 Re-school time interval (3)
- Appendix A Example of Uncertainty Evaluation of Indication Error of Instrument Thickness Measurement (4)
- Appendix B Calibration Record Format (7)
- Appendix C Calibration Certificate (End Page) Format (9)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Metering characteristics (1)
4.1 Instrument 2theta angle indication error and repeatability (1)
4.2 Thickness measurement error (1)
4.3 Film thickness measurement repeatability (1)
5 Calibration conditions (1)
5.1 Environmental conditions (1)
5.2 Measurement standards and other equipment (2)
6 Calibration items and calibration methods (2)
6.1 Calibration items (2)
6.2 Calibration method (2)
7 Calibration results (3)
8 Re-school time interval (3)
Appendix A Example of Uncertainty Evaluation of Indication Error of Instrument Thickness Measurement (4)
Appendix B Calibration Record Format (7)
Appendix C Calibration Certificate (End Page) Format (9)
Introduction
JJF 1071 "National Metrological Calibration Rules Writing Rules", JJF 1001 "General Metrology Terms and Definitions" JJF 1059.1 "Measurement Uncertainty Evaluation and Representation" and JJF 1094 "Evaluation of measuring instruments" Support the normative work to develop the basic series of norms.
This specification refers to ISO 16413.:2013 "X-ray reflectance assessment of film thickness, density and interface width Instrument requirements, collimation and positioning, data collection, data analysis and reporting "(Evaluation ofthickness, densityandinterfacewidthofthinfilmsbyX-rayreflectometry-instrumentalrequirements, alignmentandpositioning, datacolection, dataanalysisandreporting).
This specification is the first release.
Calibration standard for gravitational incidence X - ray reflectance film measuring instrument
1 Scope
This specification applies to the calibration of grazing incidence X-ray reflectance film measuring instruments (hereinafter referred to as instruments).
2 reference file
This specification refers to the following documents.
JJG629-2014 Polycrystalline X - ray Diffractometer Verification Regulation JJF 1071 national measurement calibration rules for dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.
3 Overview
The instrument is usually composed of collimated incident X-ray light source, sample table, detection system and other components (see Figure 1). its the working principle is. when the X-ray incident at a very small angle to the surface of the sample will occur when the interface reflection, the intensity of the film will change, the relationship between the reflection intensity and the reflection angle is obtained, and the film thickness can be obtained by data processing.
Figure 1 Schematic diagram of the instrument
4 measurement characteristics 4.1 instrument 2theta angle indication error and repeatability Instrument 2theta angle indication error should be within ± 0.02 °; repeatability in standard deviation, should not exceed 0.002 °.
4.2 Thickness measurement error the relative error of the measured value of the instrument should not exceed ± 6%.
4.3 film thickness measurement repeatability the instrument thickness measurement repeatability should not exceed 1%.
Note. Because the calibration work only gives the measurement results, do not determine the pass or not, the measurement characteristics are for reference only.
5 calibration conditions
5.1 Environmental conditions
5.1.1 Indoor temperature (20 ± 5) °C, humidity <= 65% RH.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJF 1613-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1613-2017
$235.00