JJF 1569-2016Calibration Specification for Bromine Number and Bromine Index Meters (English PDF)
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for JJF 1569-2016 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
June 27, 2016
Implementation date
September 27, 2016
Scope
JJF 1569-2016 (Calibration Specification for Bromine Number and Bromine Index Meters) is available as an English-translated PDF.
JJF 1569-2016 — This specification is applicable to the calibration of bromine value and bromine index measuring instruments by microcoulometric titration (coulometric method).
Found what you need?
Document preview — JJF 1569-2016
National Standard of the People's Republic of China
- ICS
- 17.020
- Classification
- A 61
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- 1 Scope
- 2 References
- 3 Terms
- 3.1 Bromine number
- 3.2 Bromine Index
- 4 Overview
- 5 Metrological characteristics
- 5.1 Indication error
- 5.2 Measurement repeatability
- 6 Calibration conditions
- 6.1 Environmental conditions
- 6.2 Calibration equipment and reference materials
- 7 Calibration items and calibration methods
- 7.1 Indication error
- 7.2 Measurement repeatability
- 8 Calibration result expression
- 9 Recalibration interval
1 Scope
This specification is applicable to the calibration of bromine value and bromine index measuring instruments by microcoulometric titration (coulometric method).
2 References
This specification refers to the following documents.
SH/T 0630-1996 Determination method of bromine value and bromine index of petroleum products (electric quantity method) SH/T 1551-1993 Determination of Bromine Index in Aromatic Hydrocarbons by Coulometric Titration for dated references, only the dated version applies to this specification; for undated references the latest version (including all amendments) applies to this specification.
3 Terms
3.1 Bromine number
Under specified conditions, the number of grams of bromine consumed when reacting with 100g of the sample is expressed in g/100g.
3.2 Bromine Index
Under specified conditions, the number of milligrams of bromine consumed when reacting with 100g of sample, expressed in mg/100g.
4 Overview
The Bromine Value and Bromine Index Meter is mainly used to determine the content of unsaturated hydrocarbons in petroleum products. when containing unsaturated hydrocarbons the sample is injected into the special electrolyte solution containing bromine, the unsaturated hydrocarbon double bond in the sample is broken, and the addition reaction occurs with the bromine bond.
The bromine consumed by the reaction is supplemented by electrolysis at the electrolytic anode. the electricity consumed by electrolysis to supplement bromine is measured, and according to Faraday's law of electrolysis, the bromine index or bromine value of the sample can be calculated.
5 Metrological characteristics
5.1 Indication error
The indication errors of the instrument in different measurement ranges are shown in Table 1.
5.2 Measurement repeatability
Instrument measurement repeatability <= 5%.
Note. The above measurement characteristic requirements are for reference only, not as a basis for judgment.
6 Calibration conditions
6.1 Environmental conditions
6.1.1 Ambient temperature. (10~35) °C, relative humidity. <=80%.
6.1.2 Power supply voltage and frequency. voltage (220±22) V, frequency (50±0.5) Hz, and the instrument is well grounded.
6.1.3 There is no strong electromagnetic field interference around, and no mechanical vibration that affects the normal operation of the calibration system.
6.2 Calibration equipment and reference materials
6.2.1 Microsyringe. full scale 1µL, 10µL, 100µL.
6.2.2 Syringe. full scale 0.5mL, 1mL, 2mL, grade A.
6.2.3 Analytical balance. graduation value (d) is 0.1mg, grade.
Each of the above appliances should be verified or calibrated, and meet the requirements of the corresponding regulations and specifications.
6.2.4 Reference material
National certified standard material for determination of bromine index and national certified standard material for determination of bromine value.
7 Calibration items and calibration methods
7.1 Indication error
7.1.1 Indication error of bromine index
Preheat the instrument and prepare reagents according to the requirements of the instrument manual, and adjust the parameters of the instrument to the normal working state.
When the zero point of the instrument reaches equilibrium, start the calibration.
In the range of (0.2~1000) mg/100g, select three (10.0, 100, 500) mg/100g or so the determination of the bromine index at the point is calibrated with the national certified standard material, and the injection volume of the standard material can be determined according to the requirements of the instrument.
Quantity or volume measurement. When injecting by mass, use an appropriate injector to extract the required volume of standard substance, and use filter paper to Dry the sampling needle, weigh the quality W1 of the sample injector on the analytical balance, and then inject the sample, the sampling needle must be fully immersed Below the liquid level of the electrolyte, inject all the sample and pull it out, wipe off the electrolyte on the surface of the injection needle, and weigh the sample again.
The quality of the sample needle is W2, input the injection volume (W1-W2) into the instrument, start the instrument to start measurement, and read Take measurements. When sampling by volume, use the required sampler to draw the standard substance to the required scale V, and then inject the sample.
The injection needle must be fully immersed below the electrolyte liquid level, after all the samples are injected, pull out, and the injection volume V and the sampling time the density of the standard substance is input into the instrument at the same time, start the instrument to start the measurement, and read the measured value after the measurement is completed.
Repeat the above steps for different concentrations of bromine index standard substances, repeat the measurement 3 times for each measurement point, and the difference between the arithmetic mean of the three measurement results of a measurement point and the standard value of the standard substance is the bromine index indication value of the instrument Error, calculated according to formula (3)
7.1.2 Indication error of bromine value
In the range of (0.1~300)g/100g, select three points around (10.0,50.0,100)g/100g the bromine standard substance was used to calibrate the instrument. Calibration method, procedure and calculation method are the same as 7.1.1.
7.2 Measurement repeatability
Under the measurement conditions of 7.1, for bromine index standard substances of about 100mg/100g and about 50.0g/100g the bromine value standard substance on the right was continuously measured 7 times under the repeatability conditions according to the method and steps in 7.1, and the repeatability was measured by bromine the relative standard deviation of the single measurement result of the index or bromine value is expressed, and the measurement repeatability sr of the instrument is calculated according to the formula (4)
8 Calibration result expression
Calibration results should be reflected on the calibration certificate or calibration report. Calibration certificates or reports include at least the following information.
a) Title. "Calibration Certificate" or "Calibration Report";
b) laboratory name and address;
c) the place where the calibration is performed (if not performed in a laboratory);
d) The unique identification (such as number) of the certificate or report, the identification of each page and the total number of pages;
e) customer name and address;
f) The description and clear identification of the school object;
g) the date on which the calibration was performed, and if relevant to the validity and application of the calibration results, the date of receipt of the object to be calibrated;
h) If relevant to the validity and application of calibration results, the sampling procedure shall be stated.
i) identification of the technical specification on which the calibration is based, including name and code;
j) Description of the traceability and validity of the measurement standards used in this calibration;
k) description of the calibration environment;
l) Explanation of calibration results and measurement uncertainty;
m) a description of deviations from calibration specifications;
n) the signature, title or equivalent identification of the issuer of the calibration certificate or calibration report;
o) A statement that the calibration result is only valid for the current measurement of the calibrated instrument;
p) Statements of certificates or reports may not be reproduced in part without the written approval of the laboratory.
9 Recalibration interval
The recalibration interval of the bromine value and bromine index detector is recommended to be 1 year. Since the length of the recalibration interval is determined by the instrument the use of the instrument, the user, the quality of the instrument itself and other factors are determined. Therefore, the sending unit can use it according to the actual use the time interval for re-calibration can be determined independently according to the situation.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
How to Download JJF 1569-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.