Valid

JJF 1563-2016Calibration Specification for Workstation of Chromatographic Data (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for JJF 1563-2016 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

June 27, 2016

Implementation date

September 27, 2016

Scope

JJF 1563-2016 (Calibration Specification for Workstation of Chromatographic Data) is available as an English-translated PDF.

JJF 1563-2016 — This standard applies to liquid chromatography, gas chromatography, ion chromatograph used in the analog interface of the calibration of the chromatographic data workstation.

Found what you need?

Document preview — JJF 1563-2016

National Standard of the People's Republic of China

ICS
17.020
Classification
A 61

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Overview (1)
  • 4 Metering characteristics (1)
  • 5 Calibration conditions (2)
  • 5.1 Environmental conditions (2)
  • 5.2 Measuring equipment (2)
  • 6 Calibration items and calibration methods (2)
  • 6.1 Sampling frequency (2)
  • 6.2 Baseline noise and baseline drift (2)
  • 6.3 Interval error and repeatability (3)
  • 6.4 Voltage indication error and repeatability (3)
  • 6.5 Dynamic Linearity (4)
  • 6.6 Qualitative Repeatability and Quantitative Repeatability (4)
  • 6.7 Quantitative error (4)
  • 7 Calibration results (4)
  • 8 Recurrence time interval (5)
  • Appendix A Chromatographic Signal Generators (6)
  • Appendix B Calibration records (for reference) (7)
  • Appendix C Calibration Certificate Inside Page Format (9)
  • Appendix D Examples of Measurement Uncertainty Evaluation (11)

1 Scope (1)

2 References (1)

3 Overview (1)

4 Metering characteristics (1)

5 Calibration conditions (2)

5.1 Environmental conditions (2)

5.2 Measuring equipment (2)

6 Calibration items and calibration methods (2)

6.1 Sampling frequency (2)

6.2 Baseline noise and baseline drift (2)

6.3 Interval error and repeatability (3)

6.4 Voltage indication error and repeatability (3)

6.5 Dynamic Linearity (4)

6.6 Qualitative Repeatability and Quantitative Repeatability (4)

6.7 Quantitative error (4)

7 Calibration results (4)

8 Recurrence time interval (5)

Appendix A Chromatographic Signal Generators (6)

Appendix B Calibration records (for reference) (7)

Appendix C Calibration Certificate Inside Page Format (9)

Appendix D Examples of Measurement Uncertainty Evaluation (11)

Introduction

This specification is based on JJF 1001-2011 "General measurement terms and definitions", JJF 1071-2010 "National measurement Calibration rules for the preparation of rules ", JJF 1059.1-2012" measurement uncertainty assessment and representation "as the basis and basis, Reference GB/T 25478-2010 "Chromatographic Data Workstation", ASTME1657-98 (2011) "Liquid Chromatography Quot; StandardPractice for Test & lt; RTI ID = 0.0 & gt; & lt;/RTI & gt;

PhotometricDetectorsUsedinLiquidChromatography).

This specification is the first release.

Standard for Calibration of Chromatographic Data Workstations

1 Scope

This specification applies to the chromatographic data of the analog interface used in liquid chromatography, gas chromatograph, ion chromatograph Station calibration. Other types of chromatographic data The calibration of the workstation can be done with reference to this specification.

2 reference file

This specification refers to the following documents.

Chromatographic Data Workstation Standard Test Method for Variable Wavelength Photometric Detectors for Liquid Chromatography (Standard PracticeforTestingVariable-WavelengthPhotometricDetectorsUsedinLiquidChroma-tography for dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.

3 Overview

The chromatographic data workstation consists of a computer, one or more data collectors and colors that convert analog signals into digital Spectrum data processing software, is able to complete the chromatograph signal conversion, data acquisition, analysis, storage and other functions Complete system.

4 measurement characteristics Chromatographic data station measurement of the technical indicators in Table 1.

Table 1 Chromatographic data workstation main technical indicators

Terms and Conditions Technical Specifications 4.1 sampling frequency >= 20Hz

4.2 Baseline noise <= 6µV

4.3 Baseline drift <=50µV/h

4.4 Maximum permissible error of time interval ± 0.6s 4.5 time interval repeatability <= 1s

4.6 Voltage indication maximum allowable error ± 1% 4.7 voltage indication repeatability <= 0.01%

4.8 Dynamic linear correlation coefficient r>=0.9998

4.9 Qualitative Repetitive RSD Retention Time <=0.3%

4.10 Quantitative repeatability RSD peak height <= 0.3%, RSD peak area <= 0.3%

4.11 Quantitative maximum allowable error ± 0.5% Note. The technical indicators are not used for qualified judgment, for reference only.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

How to Download JJF 1563-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1563-2016

$235.00