Scope
JJF 1552-2015 (Calibration Specification for Blackbody Radiation Sources of Radiation Thermometry from -10℃ to 200℃) is available as an English-translated PDF.
JJF 1552-2015 — This standard applies to radiation thermometry with a blackbody source in the range of -10 ℃ ~ 200 ℃ the effective brightness temperature calibration.
Found what you need?
Document preview — JJF 1552-2015
National Standard of the People's Republic of China
- ICS
- 17.200
- Classification
- A 54
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2 References (1)
- 3 Terminology (1)
- 4 Overview (1)
- 4.1 Use (1)
- 4.2 Principles and Structures (1)
- 4.3 Characteristics of blackbody radiation source (2)
- 5 Metrological characteristics (2)
- 5.1 Brightness temperature (2)
- 5.2 Temperature stability (2)
- 5.3 Temperature uniformity (2)
- 5.4 Insulation resistance (2)
- 6 Calibration conditions (2)
- 6.1 Environmental conditions (2)
- 6.2 Standards and auxiliary equipment (2)
- 7 Calibration items and calibration methods (3)
- 7.1 Calibration items (3)
- 7.2 Calibration method (3)
- 8 Calibration results (7)
- 9 Re-school time interval (7)
- Appendix A Blackbody Radiation Source Brightness Temperature Calibration Model (8)
- Appendix B Blackbody Radiation Source Brightness Temperature Calibration Uncertainty Evaluation Example (10)
- Appendix C Calibration Report Inside Page Reference Format (14)
1 Scope (1)
2 References (1)
3 Terminology (1)
4 Overview (1)
4.1 Use (1)
4.2 Principles and Structures (1)
4.3 Characteristics of blackbody radiation source (2)
5 Metrological characteristics (2)
5.1 Brightness temperature (2)
5.2 Temperature stability (2)
5.3 Temperature uniformity (2)
5.4 Insulation resistance (2)
6 Calibration conditions (2)
6.1 Environmental conditions (2)
6.2 Standards and auxiliary equipment (2)
7 Calibration items and calibration methods (3)
7.1 Calibration items (3)
7.2 Calibration method (3)
8 Calibration results (7)
9 Re-school time interval (7)
Appendix A Blackbody Radiation Source Brightness Temperature Calibration Model (8)
Appendix B Blackbody Radiation Source Brightness Temperature Calibration Uncertainty Evaluation Example (10)
Appendix C Calibration Report Inside Page Reference Format (14)
Introduction
This specification is based on JJF 1071-2010 "National Metrological Calibration Rules".
Blackbody radiation source as a standard radiation source, widely used in the field of radiation temperature measurement, is to study the radiation theory, Standard and calibration radiation thermometer, infrared thermal imager and other radiation thermometer necessary equipment.
This specification uses a direct contrast measurement of brightness temperature to calibrate the effective brightness of the blackbody radiation source.
This specification is the first release.
Standard for Calibration of Radiation Temperature for Rare Earth with -10 °C ~.200 °C for Radiation Temperature Measurement
1 Scope
This specification applies to radiation temperature measurement of blackbody radiation source in the -10 °C ~.200 °C range of effective brightness temperature calibration.
2 reference file
Terminology and definitions of temperature metrology nouns JJF 1007-2007 for dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.
3 terminology
3.1 [absolute] bold [absolute] blackbody Ideal radiation radiators that can absorb all the incident radiation in any direction, wavelength and polarization state.
[JJF 1007-2007, 5.9] 3.2 [cavity] blackbody radiation source [cavity] blackbodyradiationsource Used to calibrate or calibrate a radiation thermometer with a well-controlled temperature and a definite emissivity and heat radiation characteristics.
Near the black body of the concave device.
[ASTME2847-2013, 3.1.2] 3.3 [normal spectrum] emissivity [normalspectral] emissivity the ratio of the normal spectral radiance of the object to the brightness of the blackbody at the same temperature.
3.4 [effective] emissivity [effective] emissivity the ratio of the effective spectral radiance of the blackbody radiation source to the brightness of the blackbody at the same temperature.
3.5 [effective] brightness temperature [effective] radiancetemperature the temperature of the blackbody in the given wavelength range, the radiation intensity is equal to the effective radiation brightness of the measured heat radiator.
4 Overview
4.1 Use
Blackbody radiation source for calibration of radiation thermometer, infrared thermal imager and other radiation temperature measurement equipment.
4.2 Principle and structure the heat radiation in the isothermal closed cavity is blackbody. The blackbody radiation source is an isothermal cavity with small holes, which radiates Characteristic approximation is absolutely bold.
The blackbody radiation source is a source of heat that is known and stable to work.
Blackbody radiation source is usually composed of blackbody cavity, temperature measurement and control system. The cavity is usually a cylindrical cone Type, double cone type, cylindrical or spherical type.
When the blackbody radiation source is used below the dew point temperature, there should be measures to ensure that the inner surface of the cavity is free of condensation and frost.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.
How to Download JJF 1552-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays