JJF 1543-2015Calibration Specification for Visual Electrophysiological Instruments (English PDF)
This is a limited preview
Buy now to download the full PDF (19 pages)
Need quotation for your management?
Get a formal quotation for JJF 1543-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
August 24, 2015
Implementation date
November 24, 2015
Scope
JJF 1543-2015 (Calibration Specification for Visual Electrophysiological Instruments) is available as an English-translated PDF.
JJF 1543-2015 — This standard applies to the clinical use of visual electrophysiology instrument calibration.
Found what you need?
Document preview — JJF 1543-2015
National Standard of the People's Republic of China
- ICS
- 17.180
- Classification
- A 60
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (III)
- 1 Scope (1)
- 2. References (1)
- 3 Terminology and units of measurement (1)
- 3.1 Average luminance pattern (1)
- 3.2 Graphics contrast (1)
- 3.3 Brightness uniformity (1)
- 3.4 Flash intensity (1)
- 3.5 Flash duration (1)
1 Scope (1)
2 References (1)
3 Terminology and units of measurement (1)
3.1 Average luminance pattern (1)
3.2 Graphics contrast (1)
3.3 Brightness uniformity (1)
3.4 Flash intensity (1)
3.5 Flash duration (1)
Latency 3.6 (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 Flash intensity setting error (1)
5.2 Flash duration (2)
5.3 Flash stimulator background brightness setting error (2)
5.4 Graphics Contrast (2)
5.5 Graphics average brightness setting value error (2)
5.6 Graphics stimulator luminance uniformity (2)
5.7 Shows the magnitude of the electrical signal error (2)
5.8 Electrical signal frequency indication error (2)
5.9 Latency indication error (2)
Calibration Condition 6 (2)
6.1 Environmental conditions (2)
6.2 Standards and other measuring equipment (2)
7 Calibration items and calibration methods (3)
7.1 Appearance and function check (3)
7.2 Flash intensity setpoint error (3)
7.3 Flash duration (3)
7.4 Flash stimulator background brightness setting error (3)
7.5 Graphics Contrast (3)
7.6 Graphics average brightness setting error (4)
7.7 Graphics stimulator luminance uniformity (4)
7.8 Shows the magnitude of the electrical signal error (4)
7.9 Indication error frequency signals (5)
7.10 Latency indication error (5)
8 Calibration results expression (6)
8.1 Calibration records (6)
8.2 Calibration process results (6)
9 Recalibration interval (6)
Appendix A visual electrophysiology instrument calibration original records (recommended) formatting styles (7)
Appendix B calibration certificate within the page (recommended) formatting styles (10)
Appendix C Measurement Uncertainty Example (14)
Introduction
This specification is for the measurement of technical regulations visual electrophysiology instrument calibration making. Preparation of this specification to JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "common measurement terms and definitions" JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" as the basis and foundation, with reference to the ISCEV (2003) "Clinical Visual electrophysiological stimulation and recording parameters Calibration Guide" (Guidelinesforcalibrationofstimulusand recordingparametersusedinclinicalelectrophysiologyofvision) regulations.
This specification is the first release.
Calibration Specification for visual electrophysiology
1 Scope
This instruction applies to visual electrophysiology instrument calibration clinical use.
2. References
This specification refers to the following documents.
ISCEV (2003) "clinical visual electrophysiological stimulation and recording parameters Calibration Guide" (Guidelinesforcali-brationofstimulusandrecordingparametersusedinclinicalelectrophysiologyofvision) for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 terminology and units of measurement
3.1 Graphics average luminance meanluminanceofpattern the average of the graphic form of the highest brightness and the lowest brightness, unit. candela per square meter, symbol. cd/m2.
3.2 Graphics contrast patterncontrast Drawing light grid brightness and brightness contrast dark grid, expressed as a percentage.
3.3 brightness uniformity luminanceuniformity Graphics stimulator full brightness uniformity of display when expressed as a percentage.
3.4 flash intensity Instantaneous flash of brightness integrated value time unit. seconds candela per square meter, symbol. cd · s/m2.
3.5 flash duration Single flash duration, unit. milliseconds symbol. ms.
3.6 latency
Eye irritation from the received light signal to an electrical signal characteristic between the time delays, unit. milliseconds symbol. ms.
4 Overview
Visual electrophysiology instrument is one kind of electrophysiological signals measured by the human visual system after light stimuli to diagnose Instrument of visual function.
Visual electrophysiology instrument to the human eye to light stimulation signal emitted by the stimulator while collecting electrode by the human visual system Biological signals generated by the electrical signal amplification and processing after recording and display, providing for clinical visual function Medical diagnosis. Visual electrophysiology instrument by the flash stimulation, graphics stimulator, electrode, signal acquisition, data processing Operating system and the display system.
5 Metrological characteristics 5.1 flash intensity settings error no more than ± 10%.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
How to Download JJF 1543-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1543-2015
$524.00