Scope
JJF 1540-2015 (Calibration specification for online testers of winding temperature rise) is available as an English-translated PDF.
JJF 1540-2015 — This Standard applies to power frequency (50 Hz or 60 Hz) line winding temperature rise tester under conditions (hereinafter referred to as the tester) calibration resistor function.
Found what you need?
Document preview — JJF 1540-2015
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 55
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Overview (1)
- 4 Metrological characteristics (1)
- 4.1 DC resistance (1)
- 4.2 Load voltage changes affect the amount of (1)
- 5 Calibration conditions (1)
- 5.1 Environmental conditions (1)
- 5.2 Power supply (1)
- 5.3 Standards and other measuring equipment (2)
- 6 Calibration items and calibration methods (2)
- 6.1 Calibration items (2)
- 6.2 Calibration Method (2)
- 7 Calibration Results The expression (4)
- 8 Recalibration interval (4)
- Appendix A Calibration original record format (5)
- Appendix B Calibration Certificate page format (6)
- Appendix C Calibration certificate calibration results page format (7)
- Appendix D Resistance temperature measurement calculation formula (8)
- Appendix E Measurement Uncertainty Example (9)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Metrological characteristics (1)
4.1 DC resistance (1)
4.2 Load voltage changes affect the amount of (1)
5 Calibration conditions (1)
5.1 Environmental conditions (1)
5.2 Power supply (1)
5.3 Standards and other measuring equipment (2)
6 Calibration items and calibration methods (2)
6.1 Calibration items (2)
6.2 Calibration Method (2)
7 Calibration Results The expression (4)
8 Recalibration interval (4)
Appendix A calibration original record format (5)
Appendix B Calibration Certificate page format (6)
Appendix C calibration certificate calibration results page format (7)
Appendix D resistance temperature measurement calculation formula (8)
Appendix E Measurement Uncertainty Example (9)
Introduction
This specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment.
The drafting of this specification with reference to the use of the relevant provisions of the following national standards. GB 755 fixed and rotary motor of Energy; Part 1 GB 4706.1 Safety of household and similar electrical appliances. General requirements; GB 9706.1 Medical Electrical equipment - Part 1. General requirements for safety.
The specification for the first time to develop.
Online Winding Temperature Calibration Specification
1 Scope
This specification applies to power frequency (50Hz or 60Hz) line winding temperature rise tester under conditions (hereinafter referred to as test Tester) calibration resistor function. This specification does not apply to online inverter winding temperature rise tester calibration.
2. References
This specification refers to the following documents.
GB 755 rotary motor fixed and performance.
Part 1 GB 4706.1 Safety of household and similar electrical appliances. General requirements.
GB 9706.1 Medical Electrical Equipment Part 1. General requirements for safety.
For dated references, only the edition applies to the specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 Overview
Tester is a measure of motors and transformers and other electrical products in the charged state of the work for electronic winding temperature rise Equipment, mainly by the DC current source, filter, A/D converters, optical isolators and microcontrollers and other components, Winding temperature measurement is widely used in medical electronics, home appliances and farm equipment and other products.
Tester belong to resistance measuring instrument, its working principle is the direct current output by the constant current source to test internal winding, A voltage signal is amplified, after A/D conversion and the CPU into the display circuit, respectively measured electrical windings no pressure loading and loading resistance value obtained at power measured winding temperature resistance method (calculation formula see Appendix D) Working temperature rise for some time.
4 Metrological characteristics
4.1 DC Resistance
Tester DC resistance measurement range of 0.1ohm ~ 10kohm, the maximum permissible error does not exceed ± 0.2%.
4.2 load voltage change rate on in winding the charged state, the applied voltage variation of resistance tester indication of the impact does not exceed ± 0.2%.
Note. All the above technical indicators are not used for determining eligibility for reference only.
5 calibration conditions
5.1 Environmental conditions Ambient temperature. 20 °C ± 5 °C;
Relative humidity. 35% ~ 75%.
5.2 Power supply
a) voltage. 220V ± 22V;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJF 1540-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1540-2015
$329.00