Document preview — JJF 1533-2015

National Standard of the People's Republic of China

ICS
17.220
Classification
A 56

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metrological characteristics (1)
  • 3.1 Frequency Range (1)
  • 3.2 The maximum output power (1)
  • 3.3 Flatness (1)

1 Scope (1)

2 Overview (1)

3 Metrological characteristics (1)

3.1 Frequency Range (1)

3.2 The maximum output power (1)

3.3 Flatness (1)

Attenuation 3.4 (1)

4 Calibration conditions (1)

4.1 Calibration of environmental conditions (1)

4.2 Calibration Equipment (1)

5 Calibration items and calibration methods (2)

5.1 Calibration items (2)

5.2 Appearance and working properly check (3)

5.3 The maximum output power (3)

5.4 Frequency characteristics (3)

5.5 Flatness (6)

5.6 Attenuation (6)

6 Calibration expression (7)

7 Recalibration interval (8)

Appendix A calibration certificate page format (9)

Appendix B Measurement Uncertainty Evaluation (11)

Introduction

This specification based JJF 1071-2010 "national measurement calibration specifications write rules" Writing, terminology and measurement Uncertainty Evaluation follow JJF 1001-2011 "common measurement terms and definitions" and JJF 1059.1-2012 "measure Evaluation and Expression of Uncertainty. " this specification relates primarily white noise signal generator maximum output power, amplitude-frequency characteristics, flatness, attenuation correction quasi. Power meter calibration using a white noise signal generator maximum power output; with a spectrum analyzer or noise source calibration device Amplitude-frequency characteristics and flatness calibration white noise signal generator; using a power meter or spectrum analyzer calibration white noise signal Attenuation number generator.

This specification is the first release.

White noise signal generator calibration specification

1 Scope

This specification applies to the frequency range of 10Hz ~ 40GHz, the maximum output power range of -28dBm ~ Calibration 35dBm white noise signal generator.

2 Overview

White noise signal generator to produce the actual test system analog noise receiver for demodulation threshold (Eb/No), carrier to noise ratio (C/N), signal to noise ratio (SNR), bit error rate (BER) testing, and electromagnetic filters Compatible (EMI) testing. White noise signal from the noise source generator, amplifier, and filter network attenuators and other components.

3 Metrological characteristics

3.1 Frequency Range

Frequency range. 10Hz ~ 40GHz.

The maximum output power of 3.2 Maximum output power. (- 28 ~ 35) dBm.

3.3 Flatness

Flatness. ± 0.5dB.

3.4 Attenuation

Attenuation. (0 ~ 100) dB;

Power output range. (- 65 ~ 40) dBm;

Power spectral density. (- 120 ~ -20) dBm/Hz;

The maximum permissible error. ± 0.3dB.

Note. The above indicators are not used to determine eligibility for reference only.

4 calibration conditions

4.1 Calibration environmental conditions Ambient temperature. (23 ± 5) °C;

Relative humidity. <=80%;

Power supply. voltage (220 ± 11) V, frequency (50 ± 1) Hz;

Other. no effect on calibration work around the normal mechanical vibration and electromagnetic interference.

4.2 Calibration Equipment Calibration equipment should be certified by measurement technology through the organization and within the validity period or calibrated to meet the requirements.

Major equipment calibration as follows.

4.2.1 Spectrum Analyzer Frequency range. 3Hz ~ 43GHz;

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.

How to Download JJF 1533-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
16 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1533-2015

$519.00