JJF 1510-2015Program Pattern Evaluation of Target Flowmeter (English PDF)
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for JJF 1510-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 30, 2015
Implementation date
April 30, 2015
Scope
JJF 1510-2015 (Program Pattern Evaluation of Target Flowmeter) is available as an English-translated PDF.
JJF 1510-2015 — This Standard applies to the classification code for the type evaluation 12, 182, 500 target type flowmeter.
Found what you need?
Document preview — JJF 1510-2015
National Standard of the People's Republic of China
- ICS
- 17.120
- Classification
- A 52
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (III)
- 1 Scope (1)
- 2. References (1)
- 3 Terms and Definitions (1)
- 3.1 Measuring tube (1)
- 3.2 Target (1)
- 3.3 The target type flowmeter (1)
- 4 Overview (1)
- 4.1 Works (1)
- 4.2 Structure type (2)
- 5 Legal management requirements (2)
- 5.1 Units of measurement (2)
- 5.2 External structure (2)
1 Scope (1)
2 References (1)
3 Terms and Definitions (1)
3.1 Measuring tube (1)
3.2 Target (1)
3.3 The target type flowmeter (1)
4 Overview (1)
4.1 Works (1)
4.2 Structure type (2)
5 Legal management requirements (2)
5.1 Units of measurement (2)
5.2 External structure (2)
Flag 5.3 (2)
6 Measurement requirements (3)
6.1 Accuracy class and the maximum permissible error (3)
6.2 Reference error (3)
6.3 Repeatability (3)
7 General technical requirements (3)
7.1 Appearance (3)
7.2 Safety Performance (3)
7.3 Electromagnetic Environment Immunity (4)
8 Pattern evaluation item list (4)
9 Provides the number of prototype and prototype use (5)
9.1 Provide prototype number (5)
9.2 Prototype use (5)
Test methods and conditions as well as data processing and compliance criteria 10 pilot projects (5) Environmental conditions 10.1 (5)
10.2 Test medium (5)
Safety Performance Test 10.3 (5)
10.4 Metrological performance test (6)
10.5 Electromagnetic Immunity Test Environment (9)
11 Type Judgment (10) Results
11.1 Determination principle (10) of a single product
Determination principle (10) 11.2 products
12 Pilot projects are measuring instruments and equipment (10)
Appendix A pattern evaluation record format (12)
Introduction
This type of evaluation based on the outline JJF 1016 "Measuring Instruments type evaluation outline guidelines for the preparation", JJF 1015 "count the amount of equipment type and universal norms "and JJF 1001" common measurement terms and definitions of "compilation.
The outline of the type evaluation technical indicators reference JJG461-2010 "target flowmeter" and other technical regulations.
This type of evaluation outline for the first release.
The target type flowmeter type evaluation outline
1 Scope
This type of evaluation outline for categorical code 12182500 target type flowmeter (hereinafter referred to as meter) of Type evaluation.
2. References
This outline cited the following documents.
JJG461-2010 target type flowmeter GB/T 17626.2 Electromagnetic compatibility Testing and measurement techniques - Electrostatic discharge immunity test GB/T 17626.3 electromagnetic compatibility test and measurement technology RFEMS test GB/T 17626.8 Electromagnetic compatibility Testing and measurement techniques - Power frequency magnetic field immunity test for dated references, only the dated edition applies to this specification. For undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 Terms and Definitions 3.1 measuring tube metertube and some special processing techniques to meet specific requirements for the pipe section, wherein the mounting element or may be means for measuring the flow rate.
3.2 Target
Measuring tube mounted within the flow detection element.
3.3 Target Flowmeter A target plate placed in the measuring tube, through the measuring tube to force the target plate is determined by detecting the fluid flow fluid Volume flow meter.
4 Overview
Works 4.1
Setting a direction perpendicular to the stream of Target, Target surrounding fluid along a constant cross-section through a straight pipe segments, Target action by thrust, is proportional to the size of the area of the kinetic energy of the fluid and Target. In certain Reynolds number the range, proportional to the force flow through the flow meter and Target suffered. Target the force detected by the force sensor.
A circular target plate, for example, mass flow calculations see formula (1).
qm = 1.253alphagamma D2-d2 d rhoF (1) Volume flow calculation see formula (2).
qV = qm/rho = 1.253alphagamma D2-d2 (2)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
How to Download JJF 1510-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1510-2015