Valid

JJF 1505-2015Calibration Specification for Acoustic Emission Instrumentation (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for JJF 1505-2015 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 30, 2015

Implementation date

April 30, 2015

Scope

JJF 1505-2015 (Calibration Specification for Acoustic Emission Instrumentation) is available as an English-translated PDF.

JJF 1505-2015 — This Standard applies to the calibration of acoustic emission detector host, without sensor and preamplifier section.

Found what you need?

Document preview — JJF 1505-2015

National Standard of the People's Republic of China

ICS
17.140
Classification
A 59

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terms and Definitions (1)
  • 3.1 Acoustic Emission (1)
  • 3.2 Acoustic emission signal amplitude (1)
  • 3.3 Threshold (1)
  • 3.4 Impact (1)
  • 3.5 Rise Time (1)

1 Scope (1)

2 References (1)

3 Terms and Definitions (1)

3.1 Acoustic Emission (1)

3.2 Acoustic emission signal amplitude (1)

3.3 Threshold (1)

3.4 Impact (1)

3.5 Rise Time (1)

Duration 3.6 (1)

3.7 Ring Count (2)

Crosstalk 3.8 (2)

3.9 Noise (2)

4 Overview (2)

5 Metrological characteristics (2)

5.1 Noise (2)

5.2 Frequency Range (2)

5.3 Dynamic Range (2)

Between 5.4 channel crosstalk (2)

5.5 Waveform parameters (2)

6 Calibration conditions (3)

Environmental conditions 6.1 (3)

6.2 Standards and other measuring equipment (3)

7 Calibration items and calibration methods (3)

7.1 Calibration items (3)

7.2 Calibration method (4)

8 Calibration results expression (6)

8.1 Calibration Data Processing (6)

8.2 Calibration certificate (7)

8.3 Calibration measurement uncertainty (7)

9 Recalibration interval (7)

Appendix A Recommended acoustic emission detector calibration certificate-page format (8)

Appendix B acoustic emission detector calibration Uncertainty Evaluation for instance (10)

Introduction

This specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment.

Making reference to this specification JB/T 8283-1999 "acoustic emission testing equipment performance testing methods" and ASTM E0750-10 "acoustic emission instrument characterization methods" (PracticeforcharacterizingAcousticEmissionIn-strumentation) acoustic emission detector part of the performance parameters and test methods.

This specification is the first release.

Acoustic emission detector calibration specification

1 Scope

This standard applies to the calibration of acoustic emission detector host, without sensor and preamplifier section.

2. References

This specification references the following documents.

JJF 1001 common measurement terms and definitions JJF 1034 acoustic measurement terminology and definitions GB 3102.7-1993 Quantities and units of acoustics GB/T 12604.4-2005 Terminology for nondestructive testing - Acoustic emission testing JB/T 8283-1999 acoustic emission detector performance test method ASTME0750-10 acoustic emission instrument characterization methods (PracticeforcharacterizingAcoustic EmissionInstrumentation) for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 Terms and Definitions this specification uses quantities and units specified in GB 3102.7-1993.

JJF 1001 and JJF 1034 and as defined in the following terms and definitions apply to this specification.

3.1 Acoustic emission Rapid release of energy within the material phenomenon generated by transient elastic waves.

[GB/T 12604.4-2005, Definition 2.1] 3.2 acoustic emission signal amplitude the maximum peak voltage amplitude of the waveform acoustic emission signals obtained.

Note. Unit V, usually expressed in dB, the reference value 1µV.

3.3 Threshold thresholdvalue A predetermined voltage value, the acoustic emission signal amplitude exceeds the voltage value can be detected, usually in dB Shown, the reference value 1µV.

NOTE. The threshold is generally also called threshold.

3.4 strike hit

Exceeds the threshold and cause any signal acoustic emission detector channel data collection.

3.5 rise time AE signal exceeds the first threshold value to the maximum amplitude of the elapsed time interval.

3.6 Duration durationtime AE signal exceeds the threshold for the first time to descend to the final time threshold interval.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

How to Download JJF 1505-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1505-2015

$235.00