Valid

JJF 1501-2015Calibration Specification for Single Low Power LED (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for JJF 1501-2015 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 30, 2015

Implementation date

April 30, 2015

Scope

JJF 1501-2015 (Calibration Specification for Single Low Power LED) is available as an English-translated PDF.

JJF 1501-2015 — This Standard applies to the supply current of 20 mA calibration parameters of luminosity and color-line single light-emitting diode, the other the power of single LED calibration specification may refer to this execution.

Found what you need?

Document preview — JJF 1501-2015

National Standard of the People's Republic of China

ICS
17.180
Classification
A 60

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terms (1)
  • 3.1 LED average luminous intensity (1)
  • 3.2 The total luminous flux (1)
  • 3.3 Chromaticity coordinates (1)

1 Scope (1)

2 References (1)

3 Terms (1)

3.1 LED average luminous intensity (1)

3.2 The total luminous flux (1)

3.3 Chromaticity coordinates (1)

Peak wavelength 3.4 (1)

3.5 Half-peak bandwidth (1)

3.6 Dominant wavelength (1)

Purity excited 3.7 (2)

4 Overview (2)

5 Metrological characteristics (2)

Calibration Condition 6 (2)

6.1 Environmental conditions (2)

6.2 Standards and other measuring equipment (2)

7 Calibration items and calibration methods (3)

7.1 Calibration items (3)

7.2 Calibration method (4)

8 Calibration results (11)

9 Recalibration interval (11)

Appendix A LED tube calibration certificate data page format (12)

Appendix B original record format (recommended) (14)

Appendix C LED pipe average luminous intensity measurement uncertainty instance (18)

Appendix D LED tube color parameter estimation of measurement uncertainty instance (21)

Appendix E LED tube total luminous flux measurement uncertainty instance (24)

Introduction

This specification reference CIE127.2007 "LED Measurement" (MeasurementofLEDs) and of the relevant existing Photometric requirements, procedures colorimetric measurement and LED light color parameter measurement techniques developed for single supply current DIP LED luminosity and color calibration parameters of 20mA.

Low-power LED single-tube calibration specification

1 Scope

This standard applies to the supply current of 20mA-line single light emitting diode (hereinafter referred to as LED) light Calibration and color parameters, other power single LED calibration specification may refer to this execution.

2. References

This specification references the following documents.

JJG213-2003 distribution (color) temperature standard lamp JJG384-2002 spectral irradiance standard lamp JJF 1032-2005 optical radiation measurement terminology and definitions CIE127.2007 LED Measurement (MeasurementofLEDs) for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 Terms

3.1 LED average luminous intensity averagedLEDluminousintensity when measuring a predetermined value from the LED tube distal end surface of the optical detector effective receiving surface (an area of 100mm2) of Too luminous intensity, in units of cd.

CIE standard conditions A (far field). measuring distance 316mm. Corresponding solid angle 0.001sr, symbol as ILEDA.

CIE standard conditions B (near field). measured distance is 100mm. Corresponding solid angle 0.01sr, symbol as ILEDB.

3.2 The total flux totalluminousflux the sum of the flux emitted by the light source to the entire space, symbol Phi, the unit is 1m.

3.3 chromaticity coordinates each tristimulus value than the sum of its.

Note.

1 because three chromaticity coordinates equals 1, so only the two of them is sufficient to determine the chromaticity.

2 in the CIE standard colorimetric system, the chromaticity coordinates by the symbol X, Y, Z represents.

3.4 peak wavelength Maximum spectral power distribution corresponding to a wavelength, lambda P symbols, in units of nm.

3.5 half-peak bandwidth spectralbandwidthathalfintensitylevels Spectral power distribution curve ordinate equal to 1/2 of the peak corresponding to the difference between the two wavelengths, in units of nm.

3.6 main wavelength dominantwavelength (ofacolourstimulus) when the non-specific stimulation and monochromatic color additive mixing ratio in an appropriate stimulation to match the color stimulus considered the single Color stimulus wavelength. Units of symbols lambdad nm. For reference non-color LED and other energy stimulus is white (illuminant

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

How to Download JJF 1501-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1501-2015

$415.00