JJF 1494-2014Calibration Specification for Network Cable Analyzers (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (19 pages)

Need quotation for your management?

Get a formal quotation for JJF 1494-2014 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

November 17, 2014

Implementation date

February 17, 2015

Scope

JJF 1494-2014 (Calibration Specification for Network Cable Analyzers) is available as an English-translated PDF.

JJF 1494-2014 — This Standard applies to testing 5, 5E, 6 etc. twisted-pair cable network analyzer calibration. Testing over 6 class 7 class twisted-pair network cable analyzer can use reference.

Found what you need?

Document preview — JJF 1494-2014

National Standard of the People's Republic of China

ICS
17.220
Classification
A 56

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terminology and units of measurement (1)

1 Scope (1)

2 References (1)

3 Terminology and units of measurement (1)

The propagation delay of 3.1 (1)

3.2 Near-end crosstalk (1)

3.3 Equivalent far-end crosstalk (1)

4 Overview (1)

5 Metrological characteristics (1)

5.1 DC loop resistance (1)

Propagation delay of 5.2 (2)

5.3 Insertion Loss (2)

5.4 Near-end crosstalk (2)

5.5 Equivalent far-end crosstalk (2)

Return Loss 5.6 (2)

Length 5.7 (2)

Calibration Condition 6 (2)

6.1 Environmental conditions (2)

6.2 Standards and other measuring equipment (2)

7 Calibration items and calibration methods (4)

7.1 Appearance and working properly check (4)

7.2 DC loop resistance (4)

Propagation delay of 7.3 (5) Insertion Loss 7.4 (5)

7.5 Near-end crosstalk (5)

7.6 Equivalent far-end crosstalk (6)

7.7 Length (8)

7.8 Return Loss (8)

8 Expression, calibration results (9)

9 Recalibration interval (9)

Appendix A Calibration Record Form (10)

Appendix B DC loop resistance calibration Measurement Uncertainty (18)

Appendix C return loss aid and RJ45 calibration member (21)

Appendix D impedance converter (22)

Appendix E ELFEXT simulator (23)

Introduction

Prepared on the basis of the calibration standard is JJF 1071-2010 "national measurement calibration specifications writing rules" and JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement." this calibration technique based on the following main specifications of international standards.

IEC 61156-1 "digital telecommunication use of quad-core symmetric multi-cable, Part 1. Generic specification" (Mul-ticoreandsymmetricalpair/quadcablesfordigitalcommunications-Part 1. Generic specification);

IEC 61935-1 "balanced and coaxial information technology cabling test specification, Part I. The ISO/IEC 11801 Wiring and balance "(Specificationforthetestingofbalancedand the relevant provisions of the standard installation coaxialinformationtechnologycabling-Part 1. Instaledbalancedcablingasspecifiedin ISO/IEC 11801andrelatedstandards);

ANSI/T IA/EIA-568 "Commercial Building Telecommunications Cabling Standard. balanced twisted-pair cabling and telecommunications hardware connection standard Quasi "(CommercialBuildingTelecommunicationsCablingStandard. BalancedTwisted-PairTelecommunicationsCablingandcomponentsStandard);

IEEEStd802.3-2008 "communication information between the local network and metropolitan area networks two systems exchange index requirements" (Telecommunicationsandinformationexchangebetweensystems-Localandmetropoli-tanareanetworks-Specificrequirements).

This specification is the first release.

Cable network analyzer calibration specification

1 Scope

This standard applies to testing 5,5E, 6 etc. twisted pair cable network analyzer calibration. Testing over 6 category, 7 twisted pair cable network analyzer can use reference.

2. References

TIA-1152 balanced twisted-pair cabling field test instruments and measurement requirements (RequirementsforField TestInstrumentsandMeasurementsforBalancedTwisted-PairCabling) for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement 3.1 propagation delay Between the plane of the cable assembly, spread transverse electromagnetic (TEM) waves within the frequency range of each frequency Phase delay, in nanoseconds (ns).

3.2 NEXT near-endcross-talk, NEXT A link, send in a line on the cable side, the same side of the other adjacent (receiving) line through Signal coupling caused by the electromagnetic induction, in decibels (dB).

3.3 ELFEXT equallevelfarandcrosstalk, ELFEXT A link, send in a line on the cable side, the other side of the other adjacent (receiving) line on Signal is coupled through electromagnetic induction caused, i.e., far-end crosstalk.

Equivalent far-end crosstalk refers to a distal end of the receiving line crosstalk and signal attenuation on the transmission line to the poor, in minutes Tony (dB).

4 Overview

Cable network analyzer consists of two parts of the test host and remote. Cable Analyzer host generates a signal, and then Closing the distal end of the signal sent back for data analysis and processing; of the remote host sends back a response signal.

Network cable analyzer for testing LAN physical layer parameters, the quality of network cabling used in network cabling in advance Installation or troubleshooting subsequent failure to maintain the network, is a cabling system certification testing to determine its communication and transmission Analytical instruments necessary to achieve national or international performance standards and use.

Cable network analyzer main digital testing technologies and time domain reflectometry technology to achieve quick test.

5 Metrological characteristics

5.1 DC loop resistance Measuring range. (0 ~ 50) ohm; maximum permissible error. ± (1% reading 1ohm).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

How to Download JJF 1494-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1494-2014

$415.00