JJF 1473-2014Calibration Specification for Medical Diagnostic X-ray Non-invasive Current Meters (English PDF)
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for JJF 1473-2014 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
August 25, 2014
Implementation date
November 25, 2014
Scope
JJF 1473-2014 (Calibration Specification for Medical Diagnostic X-ray Non-invasive Current Meters) is available as an English-translated PDF.
JJF 1473-2014 — This Standard applies to non-invasive medical diagnostic X-ray current device, as well as non-intrusive current timetable and versatile X-ray detector calibration of X-ray tube current measuring section.
Found what you need?
Document preview — JJF 1473-2014
National Standard of the People's Republic of China
- ICS
- 17.240
- Classification
- A 58
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terminology and units of measurement (1)
- 3.1 The term (1)
- 3.2 Units of measurement (1)
- 4 Overview (1)
- 5 Metrological characteristics (1)
- 5.1 Current Range (1)
- 5.2 Current Resolution (2)
- 5.3 Indication error (2)
- 5.4 Tilt effect (2)
- 5.5 Repeatability (2)
1 Scope (1)
2 References (1)
3 Terminology and units of measurement (1)
3.1 The term (1)
3.2 Units of measurement (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 Current Range (1)
5.2 Current Resolution (2)
5.3 Indication error (2)
5.4 Tilt effect (2)
5.5 Repeatability (2)
Calibration Condition 6 (2)
6.1 Environmental conditions (2)
6.2 Standards and other measuring equipment (2)
7 Calibration methods and calibration items (2)
7.1 Current Resolution (2)
7.2 Indication error (2)
7.3 Tilt effect (3)
7.4 Repeatability (3)
8 Calibration results expression (3)
9 Recalibration time intervals (3)
Appendix A current meter connection instructions (4)
Appendix B non-invasive medical diagnostic X-ray calibration current original records (recommended) formatting styles (5)
Appendix C calibration certificate within the page (recommended) formatting styles (7)
Uncertainty Evaluation Examples Appendix D shows the current value of error measurement results (8)
Introduction
This specification based JJF 1001-2011 "common measurement terms and definitions", JJF 1059.1-2012 "measurement is not Determine the evaluation and expression ", JJF 1071-2010" National Calibration Specifications writing rules "establishment.
For non-invasive medical diagnostic X-ray apparatus of the current situation, the development of this specification reference JJF 1075-2001 "clamp meter calibration norms" and JJG598-1989 "DC digital ammeter (Trial)." the specification for the first time to develop.
Non-invasive medical diagnostic X-ray calibration current specification
1 Scope
This instruction applies to non-invasive medical diagnostic X-ray current device, as well as non-intrusive current timetable and versatile X Calibration X-ray tube current measuring section ray detector.
2. References
This specification refers to the following documents.
JJG598 DC digital ammeter (Trial) JJG744 diagnostic X-ray radiation JJF 1075 clamp meter calibration specification for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 terminology and units of measurement
3.1 Terms
3.1.1 X-ray tube current X-raytubecurrent Current electron beam against the X-ray tube target surface.
[IEC 60601-1-3:2008,3.85]
3.1.2 Non-intrusive measurement of non-invasivemeasurement Obtain measurements of X-ray tube current values by measuring the non-access current probe signal.
3.1.3 intervention measure invasivemeasurement to obtain an X-ray tube current values measured by access to appropriate current instrument.
3.1.4 Non-intrusive current probe non-invasivecurrentprobe Referred to the probe, used as probe clamp meter, using electromagnetic induction principle, measure the current signal.
3.2 units of measurement Title X-ray tube current unit. mA; symbol. mA.
4 Overview
Medical Diagnostic X-ray non-intrusive current device (hereinafter referred to as the current instrument) is a non-invasive way to measure the use of X-rays Ray machine tube current instrument for measuring the X-ray exposure of the current machine. Current meter according to the principle of electromagnetic induction to detect Exposure tube current signal induced current signal acquisition and processing, calculation of the current value. Current instrument is mainly handled by the probe signal Means for processing terminals and other components.
5 Metrological characteristics
5.1 Current Range
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJF 1473-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1473-2014
$205.00