JJF 1470-2014Calibration Specification for Multiparameter Physiological Simulators (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for JJF 1470-2014 in 30 minutes.

Issued by

Wu Wenjun (General Logistics Department of the Ministry of Health Drug and Instrument Control), Paragraph Xin'an (General Logistics Department of the Ministry of Health Drug and Instrument Control), WU Jian-gang (General Logistics Department of the Ministry of Health Drug and Instrument Control)

Level / Type

National · Mandatory

Issue date

August 1, 2014

Implementation date

November 1, 2014

Scope

JJF 1470-2014 (Calibration Specification for Multiparameter Physiological Simulators) is available as an English-translated PDF.

JJF 1470-2014 — This Standard applies to multiple physiological parameters simulated instrument calibration.

Found what you need?

Document preview — JJF 1470-2014

National Standard of the People's Republic of China

ICS
17.220
Classification
A 56

Issued by: Wu Wenjun (General Logistics Department of the Ministry of Health Drug and Instrument Control), Paragraph Xin'an (General Logistics Department of the Ministry of Health Drug and Instrument Control), WU Jian-gang (General Logistics Department of the Ministry of Health Drug and Instrument Control)

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terminology and units of measurement (1)
  • 3.1 The term (1)
  • 3.2 Units of measurement (1)
  • 4 Overview (1)
  • 5 Metrological characteristics (2)
  • 5.1 ECG signal amplitude (2)
  • 5.2 Heart rate (2)
  • 5.3 Respiratory base impedance (2)
  • 5.4 Analog blood pressure signals (2)
  • 5.5 Cardiac output analog signals (2)
  • 5.6 Analog temperature signal (2)
  • 5.7 Reference Waveform (2)

1 Scope (1)

2 References (1)

3 Terminology and units of measurement (1)

3.1 The term (1)

3.2 Units of measurement (1)

4 Overview (1)

5 Metrological characteristics (2)

5.1 ECG signal amplitude (2)

5.2 Heart rate (2)

5.3 Respiratory base impedance (2)

5.4 Analog blood pressure signals (2)

5.5 Cardiac output analog signals (2)

5.6 Analog temperature signal (2)

5.7 Reference Waveform (2)

Calibration Condition 6 (2)

6.1 Environmental conditions (2)

6.2 Standards and other measuring devices (2)

7 Calibration items and calibration methods (3)

7.1 ECG signal amplitude (3)

7.2 Heart rate (4)

7.3 Respiratory impedance base (4)

7.4 Analog blood pressure signals (5)

7.5 Cardiac output analog signals (5)

7.6 Temperature analog signals (6)

7.7 Reference Waveform (7)

8 Calibration results expression (7)

8.1 Calibration records (7)

8.2 Calibration process results (7)

9 Recalibration interval (8)

Appendix A calibration record format (9)

Appendix B Calibration Certificate page format (12)

Appendix C Measurement Uncertainty Example (15)

Introduction

This specification based JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" establishment.

This specification more physiological parameters of a typical analog instrument metrological characteristics with reference to the domestic market mainstream brands Technical Specifications determine.

The specification for the first time to develop.

Multi-parameter simulation Calibration physiological norm

1 Scope

This instruction applies to multi-parameter physiological simulation instrument calibration.

2. References

This specification refers to the following documents.

GB 9706.25-2005 Medical electrical equipment - Part 2-27. ECG monitoring equipment safety requirements for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement

3.1 Terms

3.1.1 Multi-parameter physiological simulator multiparametersimulators Simulated human ECG, respiration, invasive blood pressure, cardiac output and medical testing equipment, body temperature and other physiological parameters, the main Parameters to be used for multi-parameter monitors and other medical equipment for testing.

Lead lead [3.1.2] GB 9706.25-2005,2.102 Electrodes for ECG recording of a connection.

3.1.3 arrhythmia an exception occurred site of origin of heart rate, cardiac frequency and rhythm and conduction.

3.1.4 sinus sinusrhythm Electrical impulses emitted by the heart rhythm caused by sinus node activity.

3.2 units of measurement Units of measurement and reference ECG waveform amplitude is mV, the reference waveform frequency unit Hz; respiratory group Base impedance measurement unit is generally ohm.

4 Overview

Multi-parameter physiological simulator is mainly used for multi-parameter patient quality control and technical training monitor can output sine Wave, square wave and triangular wave reference waveform, and can simulate human ECG, respiration, invasive blood pressure, cardiac output, body temperature and many other electrophysiological parameters. Various waveforms required by the digital to analog converter and physiological signals generated by the input signal amplitude and frequency Into the digital control. ECG signal generated by the microcontroller control DAC, via a resistor network attenuated by a guide Union Distribution network output; analog signals through analog breathing respiratory impedance changes, with ECG output; blood pressure Analog signal generated by the resistive bridge sensors, and the applied voltage is proportional to the excitation; cardiac output analog signals using heat the relationship between resistance and temperature-sensitive indirect simulation; analog temperature thermistor resistance value at a specified temperature Simulation.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

How to Download JJF 1470-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1470-2014

$355.00