JJF 1461-2014Calibration Specification for Lower Power Transfer Standards (English PDF)
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for JJF 1461-2014 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
April 21, 2014
Implementation date
July 21, 2014
Scope
JJF 1461-2014 (Calibration Specification for Lower Power Transfer Standards) is available as an English-translated PDF.
JJF 1461-2014 — This Standard specifies the frequency range of 100 kHz-50 GHz, power measurement range of 0. 5mW - a variety of low-power 10mW of calibration transfer standards.
Found what you need?
Document preview — JJF 1461-2014
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 56
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (III)
- 1 Scope (1)
- 2. References (1)
- 3 Terminology and units of measurement (1)
- 3.1 Terminating Power Standard calibration factor (1)
- 3.2-through power standard calibration factor (1)
- 4 Overview (1)
- 5 Metrological characteristics (1)
1 Scope (1)
2 References (1)
3 Terminology and units of measurement (1)
3.1 Terminating Power Standard calibration factor (1)
3.2-through power standard calibration factor (1)
4 Overview (1)
5 Metrological characteristics (1)
Calibration Condition 6 (2)
6.1 Calibration environmental conditions (2)
6.2 Calibration Equipment (2)
7 Calibration items and calibration methods (3)
7.1 Calibration items (3)
7.2 Appearance and working properly check (3)
7.3 Transfer standard calibration factors by type of small power (3)
7.4 Terminating small power transfer standard calibration factor (4)
7.5 Terminal Small Power Transfer Standard input reflection coefficient modules (6)
7.6 Transfer standard equivalent source reflection coefficient modules (6) by low-power formula
8 Calibration results expression (8)
9 Recalibration interval (8)
Appendix A calibration record format (9)
Appendix B Calibration Certificate-page format (11)
Appendix C Evaluation of Uncertainty in Measurement (13)
Introduction
This specification based JJF 1071-2010 "national measurement calibration specifications write rules" Writing, terminology and measurement Uncertainty Evaluation follow JJF 1001 "common measurement terms and definitions" and JJF 1059.1 "Measurement Uncertainty and said, "two documents.
This specification relates primarily small power transfer standard calibration factor and the reflection coefficient modulus values. Alternating Comparison Law and Standards Act passed the calibration terminal Small Power Transfer Standard calibration factor; uses Terminating Power Standard direct calibration Pass-through low-power standard calibration factor; a network analyzer calibration terminal Small Power Transfer Standard input End reflection coefficient modulus.
This specification is the first release.
Small Power Transfer Standard Calibration Specification
1 Scope
This standard applies to the frequency range of 100kHz ~ 50GHz, power measurement range of 0.5mW ~ 10mW A variety of small power transfer standard calibration.
2. References
This specification refers to the following documents.
JJF 1001 common measurement terms and definitions.
For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 terminology and units of measurement the following definitions of terms apply to this specification.
3.1 Terminating Power Standard calibration factor calibrationfactorofterminatingpowerstandard DC alternative power Pb incident bolometer element to the seat of power than the power of Pi, by Kb FIG.
3.2-through power standard calibration factor calibrationfactoroffeedthroughpowerstandard Next to the directional coupler alternative power Pbc incident arm (or splitters side output terminal) connected to a power seat set the main arm to the coupler output (or the other side of the splitter output) than non-reflective power Po of the load, with Kc FIG.
4 Overview
Small Power Transfer Standard is standard equipment for the power value transfer based on their access to the system is not the way the same is divided into two types by passing a standard formula transfer standard and low-power terminal type.
Small power transfer through a standard thermistor power seat, directional coupler (or power divider) and the power indicator (Or power bridge) components.
Small Power Transfer Standard Terminal from the power seat and power indicator (or power bridge) composition, or by the formula Low-power standard output matched load components.
5 Metrological characteristics
a) Frequency range. 100kHz ~ 50GHz;
b) Power measurement range. 0.5mW ~ 10mW;
c) Measurement Uncertainty of calibration factors. 0.6% ~ 5.0% (k = 2);
d) the reflection coefficient modulus value. not more than (0.1 to 0.25).
Note. The above indicators are not used to determine eligibility for reference only.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
How to Download JJF 1461-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1461-2014