Scope

JJF 1458-2014 (Calibration Specification for Magnetic Yoke Detectors) is available as an English-translated PDF.

JJF 1458-2014 — This Standard specifies the electromagnetic clutch type magnetic detection machines, cross-calibration yoke (rotating magnetic field) testing machine.

Found what you need?

Document preview — JJF 1458-2014

National Standard of the People's Republic of China

ICS
17.220
Classification
A 55

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terminology and units of measurement (1)
  • 3.1 Magnetizing current (1)
  • 3.2 Yoke (1)
  • 3.3 Cross yoke (1)

1 Scope (1)

2 References (1)

3 Terminology and units of measurement (1)

3.1 Magnetizing current (1)

3.2 Yoke (1)

3.3 Cross yoke (1)

Lifting force 3.4 (1)

4 Overview (1)

5 Metrological characteristics (2)

5.1 Magnetizing current (2)

5.2 Safety Performance (2)

Integrated Sensitivity 5.3 (2) Lifting force 5.4 (3)

6 Calibration conditions (3)

Environmental conditions 6.1 (3)

6.2 Standards and other measuring equipment (3)

7 Calibration items and calibration methods (4)

7.1 Calibration items (4)

7.2 Calibration method (4)

8 Calibration results expression (5)

9 Recalibration interval (6)

Appendix A Measurement Uncertainty Example (7)

Appendix B Calibration original record format (10)

Appendix C calibration certificate page format (11)

Appendix D standard test piece of type, size, and graphics (13)

Appendix E magnetic carrier and magnetic suspension (14)

Introduction

This specification based on the national measurement specifications JJF 1071-2010 "National Calibration Specifications writing rules" JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement", JJF 1001-2011 "universal metering and fixed term Meaning "prepared to develop.

This specification is the first release.

Yoke type magnetic particle testing machine calibration specification

1 Scope

This standard applies to magnetic yoke-type magnetic detection machines, cross yoke (rotating magnetic field) testing machine calibration. Not applicable AC, DC (half-wave rectification or full-wave rectification) magnetic particle testing machine calibration.

2. References

This specification refers to the following documents.

JJF 1273-2011 magnetic particle inspection machine calibration specification GB/T 5097-2005 destructive testing - Penetrant testing and magnetic particle testing - Viewing conditions GB/T 15822.3-2005 destructive testing equipment Magnetic particle testing - Part 3 JB/T 4730.4-2005 Nondestructive Testing pressure equipment Part 4 Magnetic particle testing JB/T 6065-2004 Nondestructive Testing magnetic detection test piece for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement this specification uses quantities and units specified in GB 3102.5.

3.1 magnetizing current Rms ac current yoke type magnetic flaw detector is working properly. DC magnetic yoke-type magnetic detection machines to work the current average. Unit. ampere (A).

3.2 yoke magneticyoke Part of the magnetic circuit, its main function is to provide a low reluctance magnetic flux path.

Note. The yoke widely used relatively high permeability soft iron, A3 steel, and soft magnetic alloys to produce, in some special occasions, but also the yoke Useful ferrite material manufactured.

3.3 Cross yoke crossedyoke on the same plane (or surface), having a certain phase difference (not equal to 0 ° or 180 °) and cross-cutting Angle (not equal to 0 ° or 180 °) of the two-phase sinusoidal alternating magnetic field superimposed on each other, and in the plane (or surface) on the rotating magnetic field of the magnetic detection devices.

3.4 Lifting force when the solenoid yoke pole at maximum distance, the magnetic flux density which produces a peak magnetic field of ferromagnetic workpieces Testing appeal.

NOTE. For engineering practice, with respect to the exchange of electromagnetic yoke, lifting force equal to its average suction yoke poles. Newtons (N).

4 Overview

Magnetic particle inspection is to detect ferromagnetic material surface and near-surface defect detecting method used. When the workpiece is

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

How to Download JJF 1458-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1458-2014

$235.00