Document preview — JJF 1450-2014

National Standard of the People's Republic of China

ICS
17.100
Classification
A 53

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (III)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Overview (1)
  • 4 Legal management requirements (1)
  • 4.1 Units of measurement (1)
  • 4.2 The maximum permissible error (1)
  • 4.3 Legal metrology marking and identification of measuring instruments (1)
  • 4.4 Test Prototype (2)
  • 5 Measurement requirements (2)
  • 5.1 Wind represents error (2)
  • 5.2 Meter wind measuring range (2)
  • 5.3 Start vane wind speed (2)
  • 5.4 Winds indicates error (2)
  • 5.5 Anemometer measurement error (2)
  • 5.6 Anemometer measurement range (2)
  • 5.7 Wind speed swing pointer (2)
  • 5.8 Start up wind speed wind cup (2)
  • 6 General Requirements (2)
  • 6.1 Appearance (2)
  • 6.2 Mechanical properties (3)

1 Scope (1)

2 References (1)

3 Overview (1)

4 Legal management requirements (1)

4.1 Units of measurement (1)

4.2 The maximum permissible error (1)

4.3 Legal metrology marking and identification of measuring instruments (1)

4.4 Test Prototype (2)

5 Measurement requirements (2)

5.1 Wind represents error (2)

5.2 Meter wind measuring range (2)

5.3 Start vane wind speed (2)

5.4 Winds indicates error (2)

5.5 Anemometer measurement error (2)

5.6 Anemometer measurement range (2)

5.7 Wind speed swing pointer (2)

5.8 Start up wind speed wind cup (2)

6 General Requirements (2)

6.1 Appearance (2)

6.2 Mechanical properties (3)

Storage temperature 6.3 (3)

7 Type evaluation item list (3)

8 Pilot projects test methods and conditions (4)

8.1 Wind represents error (4)

8.2 Meter wind measuring range (4)

8.3 Weathervane start Winds (5)

8.4 Winds indicates error (5)

8.5 Anemometer measurement error (6)

8.6 Anemometer measurement range (6)

8.7 Wind speed swing pointer (7)

8.8 Start up wind speed wind cup (7)

8.9 Appearance (7)

8.10 Mechanical properties (8)

8.11 High and low temperature storage (8)

9 Type evaluation results to determine (9)

Appendix A portable magnetic induction wind anemometer type evaluation original record format (10)

B portable magnetic induction wind anemometer measurement error calculation appendix (15) Appendix C portable magnetic induction wind anemometer measurement equipment manufacturing license examination prerequisites (16)

Introduction

JJF 1016 "Measuring Instruments type evaluation outline guidelines for the preparation", JJF 1015 "Measuring Instruments type evaluation and type Ratify general specification ", JJF 1246" measurement equipment manufacturing license evaluation general specification ", JJF 1001" universal cytometry Language and Definitions "and JJF 1059" Evaluation and Expression of Uncertainty in Measurement "together constitute the fundamental norm-setting series specification.

The specification for the specific test methods and technical indicators refinement, additions and modifications.

This specification is the first release.

Portable magnetic induction wind anemometer type evaluation outline

1 Scope

This type of evaluation framework applies to portable magnetic induction wind anemometer (hereinafter referred to as magnetic induction wind meter) of pattern evaluation.

2. References

JJG515-1987 portable magnetic induction wind anemometer (Trial) JJG431-1986 DEM6 type light wind anemometer cups those documents by reference the terms of this syllabus constitute provisions of this outline. For dated references, all subsequent amendments (not including errata content) or revisions do not apply in this outline, however, encourage the all parties that this outline agreement to use the latest versions of these documents. For undated reference documents Member, the latest versions apply to this outline.

3 Overview

Magnetic induction wind meter is a measure of the instantaneous wind direction and speed instruments, mainly for field observation, by the anemometer and wind direction table composition. The key member includes a wind vane and wind cups.

Vane by wind vane shaft is rotated around to drive the wind direction pointer on the compass direction. Wind cup Wind cup shaft is rotated around by wind, driven by the wind cup shaft lower end of the magnet is rotated to form a rotating magnetic field around the magnet the induction coil generates eddy currents in a changing magnetic field. Induction coil under the action of the electromagnetic force, the magnet rotates along the square to deflect. Induction coil deflected to a certain angle after reaching the torque balance and gossamer. Winds pointer The induction line Deflection angle in the circle indicates the wind speed wind speed dial.

4 legal management requirements 4.1 units of measurement Magnetic induction wind table should respectively "m/s" and "(°)" as wind speed and direction units.

4.2 The maximum permissible error Wind direction magnetic induction meter maximum permissible error of ± 22.5 °, wind speed maximum permissible error of ± (0.5m/s 0.05v).

Note. v standard wind speed, m/s.

4.3 legal metrology marking and measuring instruments logo 4.3.1 legal metrology flags include the following.

--- Measurement equipment manufacturing license logo and number (test prototype should stay out of the corresponding position);

--- Induction wind flags and table type approval number (test prototype should stay out of the corresponding position; this entry is not mandatory provisions set);

--- Product certification (with magnetic induction wind provided separately from the main unit).

4.3.2 measuring instruments identified include the following.

--- Name induction wind table specification (model);

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.

How to Download JJF 1450-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
16 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1450-2014

$355.00