JJF 1448-2014Calibration Specification for Superconducting Pulsed Fourier Transform Nuclear Magnetic Resonance Spectrometers (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (11 pages)

Need quotation for your management?

Get a formal quotation for JJF 1448-2014 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

February 14, 2014

Implementation date

May 14, 2014

Scope

JJF 1448-2014 (Calibration Specification for Superconducting Pulsed Fourier Transform Nuclear Magnetic Resonance Spectrometers) is available as an English-translated PDF.

JJF 1448-2014 — This Standard applies to 300MHz and above the superconducting pulse Fourier transform NMR spectrometer (hereinafter referred to as the instrument) calibration.

Found what you need?

Document preview — JJF 1448-2014

National Standard of the People's Republic of China

ICS
17.220
Classification
A 55

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terminology and units of measurement (1)
  • 3.1 Chemical shift (1)
  • 3.2 Free induction decay (FID) (1)

1 Scope (1)

2 References (1)

3 Terminology and units of measurement (1)

3.1 Chemical shift (1)

3.2 Free induction decay (FID) (1)

Linewidth factor 3.3 (1)

4 Overview (1)

4.1 Principle (1)

4.2-instrument (2)

5 Metrological characteristics (2)

Calibration Condition 6 (2)

6.1 Laboratory environment (2)

6.2 Standard substance (2)

6.3 Experimental Condition (3)

7 Calibration items and calibration methods (3)

7.1 1H spectral sensitivity (3) 7.2 13C spectral sensitivity (3) 7.3 1H spectral resolution (4) 7.4 13C Spectral Resolution (4) 7.5 1H line type (4) 7.6 13C line type (4) 7.7 1H spectrum quantitative reproducibility (4)

8 Calibration results (4)

9 Recalibration interval (5)

Appendix A calibration record format (6)

Appendix B Calibration Certificate page format (7)

Appendix C instrument parameters is recommended (8)

Appendix D Evaluation of Uncertainty (9)

Introduction

Part of this specification with reference to the use of international instruments ASTME386-90 (2011) High-resolution nuclear magnetic resonance (NMR) Spectroscopic characterization implement data standards [StandardPracticeforDataPresentationRelatingtoHigh-ResolutionNuclearMagneticResonance (NMR) Spectroscopy].

This specification is the first release.

Superconducting pulse Fourier transform NMR spectrometer Calibration Specification

1 Scope

This instruction applies to 300MHz and above the superconducting pulse Fourier transform NMR spectrometer (hereinafter referred to as equipment) Calibration.

2. References

Characterization of the implementation of standards ASTME386-90 (2011) High-resolution nuclear magnetic resonance (NMR) spectroscopy data (StandardPracticeforDataPresentationRelatingtoHigh-ResolutionNuclearMagnetic Resonance (NMR) Spectroscopy) "Handbook of Analytical Chemistry --- Seventh Volume NMR Spectroscopy" Beijing. Chemical Industry Press for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments Version) applicable to this specification.

3 terminology and units of measurement 3.1 chemical shift Proton magnetic field in the same or other magnetic core, which because of its different chemical environment in the molecule, and in Phenomenon of resonance at different frequencies, and whose scale commonly used to measure the reference material and the sample resonance frequency difference list Shown, denoted delta, dimensionless 1.

delta =

nuS-nuR

nu instrument × 10

Where.

nuS --- the resonance frequency of the sample, Hz;

nuR --- the resonance frequency of the reference material, Hz;

nu instruments --- instrument operating frequency, Hz.

3.2 free induction decay (FID) freeiductiondecay Spin system under pulsed accept induction coil signal occurs, its intensity over time and decay.

3.3 linewidth factor linebroadeningfactor for each data point free induction decay signal is exponential weighting factor used. When the factor is equal to Zero, not weighted.

4 Overview

4.1 Principle

Nuclear magnetic resonance spectroscopy, the study has some moments of nuclei in a static magnetic field and the magnetic field due to the interaction of the magnetic moment Resonance is formed by a set of split levels, appropriate action under the RF frequency, energy level transitions occur between now and the emergence of

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.

How to Download JJF 1448-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
11 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1448-2014

$205.00