Scope
JJF 1447-2014 (Calibration Specification for Ultrasonic Flaw Detectors by Time-of-Flight Diffraction) is available as an English-translated PDF.
JJF 1447-2014 — This Standard specifies the use of ultrasonic time of flight diffraction method (time-of-flight diffraction, TOFD) ultrasonic flaw detector principle (hereinafter referred to as detectors) calibration.
Found what you need?
Document preview — JJF 1447-2014
National Standard of the People's Republic of China
- ICS
- 17.140
- Classification
- A 59
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terms (1)
- 3.1 Time of flight diffraction method (TOFD) (1)
- 3.2 TOFD image (1)
- 3.3 Lateral wave (1)
- 3.4 Bottom surface reflected wave (1)
- 3.5 Probe center spacing (PCS) (1)
- 3.6 Probe Delay (1)
- 3.7 Defect depth (1)
- 3.8 Bugs in their height (2)
1 Scope (1)
2 References (1)
3 Terms (1)
3.1 Time of flight diffraction method (TOFD) (1)
3.2 TOFD image (1)
3.3 Lateral wave (1)
3.4 Bottom surface reflected wave (1)
3.5 Probe center spacing (PCS) (1)
3.6 Probe Delay (1)
3.7 Defect depth (1)
3.8 Bugs in their height (2)
Defect length 3.9 (2)
3.10 Blind (2)
4 Overview (2)
5 Metrological characteristics (3)
5.1 Receiver bandwidth (3)
5.2 Transmit pulse rise time (3)
5.3 on the surface of the blind (3)
5.4 Defect depth, height and length measurement errors (3)
6 Calibration conditions (3)
Environmental conditions 6.1 (3)
6.2 Standards and other measuring equipment (3)
7 Calibration items and calibration methods (4)
7.1 Calibration items (4)
7.2 Calibration method (4)
8 Calibration results expression (9)
8.1 Calibration Data Processing (9)
8.2 Calibration certificate (9)
Measurement Uncertainty Evaluation 8.3 Calibration Results (9)
9 Recalibration interval (10)
Appendix A recommended flaw detector calibration record (11)
Appendix B recommended ultrasonic flaw detector calibration certificate page format (12)
Appendix C typical reference block (13)
Appendix D match test block <=400mm thick steel probe recommended selecting (14)
Appendix E time of flight diffraction method ultrasonic flaw detector flaw depth measurement error Uncertainty Evaluation Examples (15)
Introduction
This specification is based on JJF 1071-2010 "National Calibration Specifications writing rules," the preparation of requirements and coding format written.
This specification GB/T 23902-2009 "Non-destructive testing - Ultrasonic examination Diffraction technical inspections and assessment Price method "in the equipment requirements of the more important indicators made the measurement performance requirement that the inclusion of metering performance deficiencies Depth, height defect, length and the like on the surface of several blind test content. And referring to "weld NDT - Super Health Laboratory - the use of time of flight diffraction technique (TOFD) of "(ISO 10863-Welding-Useoftime-of-flightdif-fractiontechnique (TOFD) fortestingofwelds) of the time of flight diffraction method flaw detector, probes, scanning the encoder apparatus and a comprehensive evaluation.
This specification is the first release.
Time of flight diffraction method ultrasonic flaw detector calibration specification
1 Scope
This standard applies to the use of ultrasonic time of flight diffraction method (time-of-flightdiffraction, TOFD) Principle Ultrasonic flaw detector (hereinafter referred to as detectors) calibration.
2. References
This specification references the following documents.
JJF 1001-2011 common measurement terms and definitions JJF 1034-2005 acoustic measurement terminology and definitions GB 3102.7-1993 Quantities and units of acoustics GB/T 3947-1996 Acoustics Terminology GB/T 12604.1 Terminology for nondestructive testing Ultrasonic testing GB/T 23902-2009 NDT testing and evaluation methods - Ultrasonic examination Diffraction GB/T 27664.1-2011 performance and test NDT ultrasonic testing equipment - Part 1. Apparatus NB/T 47013.10 pressure equipment Non-destructive testing - Part 10. Ultrasonic testing time of flight diffraction method for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 Terms
JJF 1001-2011 and JJF 1034-2005, GB/T 12604.1 and JB/T 4730.1 ~ 4730.6 Definition the following terms and definitions apply to this specification.
3.1 Time of flight diffraction method (TOFD) timeofflightdifraction, TOFD [NB/T 47013.10,3.2] Utilization Deficiency endpoints diffracted wave signal defect is discovered and an ultrasonic flaw detection method for determination of size.
3.2 TOFD image TOFDimage TOFD scanning data of two-dimensional display, A scan signal from the scan collected during continuous mosaic.
3.3 lateral wave [NB/T 47013.10,3.5] Sonic the same group between two TOFD probes on a flat or curved surface of the shortest path propagation.
3.4 back reflection wave backwalecho [NB/T 47013.10,3.6] from the transmitting probe through the bottom surface of the reflector to the receiving ultrasonic probe.
3.5 Probe center spacing (PCS) probecenterseparation, PCS [NB/T 47013.10,3.7] Two from the probe point probe incident between a group.
3.6 Probe Delay Ultrasonic propagation time in the probe wedge.
3.7 defect depth flawdepth [NB/T 47013.10,3.9] End-to-surface distance scanning defect.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
How to Download JJF 1447-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1447-2014
$295.00