Valid

JJF 1433-2013Calibration Specification for Chlorine Alarm Detectors (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (11 pages)

Need quotation for your management?

Get a formal quotation for JJF 1433-2013 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

JJF 1433-2013 (Calibration Specification for Chlorine Alarm Detectors) is available as an English-translated PDF.

JJF 1433-2013 — This standard specifies the measurement range (0 ~ 10) µmol/mol to (0 ~ 1000) µmol/mol chlorine detection alarm (at short instrument) calibration, other instruments for the detection of chlorine can refer to this standard for calibration.

Found what you need?

Document preview — JJF 1433-2013

National Standard of the People's Republic of China

ICS
17.020
Classification
A 61

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Overview (1)
  • 4 Metrological characteristics (1)
  • 4.1 Indication error (1)
  • 4.2 Repeatability (1)
  • 4.3 Response Time (1)
  • 4.4 Alarm function (1)
  • 4.5 Drift (1)
  • 5 Calibration conditions (1)
  • 5.1 Environmental conditions (1)
  • 5.2 Calibration of measuring instruments and equipment (2)
  • 6 Calibration items and calibration methods (2)
  • 6.1 Indication error (2)
  • 6.2 Repeatability (2)
  • 6.3 Response time (3)
  • 6.4 Alarm function (3)
  • 6.5 Drift (3)
  • 7 Calibration Results The expression (3)
  • 8 Recalibration interval (4)
  • Appendix A Chlorine detection alarm calibration records (5)
  • Appendix B Certificate page format (7)

1 Scope (1)

2 References (1)

3 Overview (1)

4 Metrological characteristics (1)

4.1 Indication error (1)

4.2 Repeatability (1)

4.3 Response Time (1)

4.4 Alarm function (1)

4.5 Drift (1)

5 Calibration conditions (1)

5.1 Environmental conditions (1)

5.2 Calibration of measuring instruments and equipment (2)

6 Calibration items and calibration methods (2)

6.1 Indication error (2)

6.2 Repeatability (2)

6.3 Response time (3)

6.4 Alarm function (3)

6.5 Drift (3)

7 Calibration Results The expression (3)

8 Recalibration interval (4)

Appendix A chlorine detection alarm calibration records (5)

Appendix B Certificate page format (7)

Measurement Uncertainty Appendix C indication error of assessment (8)

Introduction

In the present specification JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "Universal Measurement Terms and definitions "and JJF 1059.1-2012" Evaluation and Expression of Uncertainty in Measurement "as the basic specification series be developed.

This specification is in accordance with GB 12358-2006 "workplace environment gas detection alarm general technical requirements" and HG/T 23006-1992 Technical Requirements "toxic gas detection alarm technical requirements and test methods" and the party Law and GB 50493-2009 "Petroleum and Chemical combustible gases and toxic gas detection and alarm design specifications" indicated Alarm equipment selection is performed making.

Indication Error of this specification to measure the relative error is expressed.

The specification for the first time to develop.

Chlorine alarm detector calibration specification

1 Scope

This standard applies to the measurement range (0 ~ 10) µmol/mol to (0 ~ 1000) µmol/mol chlorine detector newspaper Police instrument (hereinafter referred to as equipment) calibration of other instruments for the detection of chlorine can refer to this specification for calibration.

2. References

GB 12358-2006 workplace environment gas detection alarm general technical requirements GB 50493-2009 Petroleum and Chemical combustible gases and toxic gas detection and alarm design specifications HG/T 23006-1992 toxic gas detection alarm technical requirements and testing methods for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 Overview

Instrument detector main diaphragm electrode type, constant potential electrolysis type and/or semiconductor type. Sampling methods are diffused and inhaled. The main structure consists of detecting elements, amplifying circuit, alarm system, display and other components.

4 Metrological characteristics

4.1 Indication error the maximum permissible error. ± 10%.

4.2 Repeatability

Repeatability is not more than 3%.

4.3 Response Time

Diffusion of not more than 60s, inhaled not more than 30s.

4.4 Alarm function

Instrument with alarm function, alarm function should be normal.

4.5 Drift

4.5.1 Zero drift. ± 3% FS.

4.5.2 Span drift. ± 5% FS.

Note. The above indicators are not used to determine eligibility for reference only.

5 calibration conditions

5.1 Environmental conditions

5.1.1 Ambient temperature. (15 ~ 35) °C.

5.1.2 Relative humidity. <=85%.

5.1.3 work environment should not affect the normal operation of the instrument and electromagnetic interference gas calibration site should be ventilated and

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.

How to Download JJF 1433-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
11 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1433-2013

$205.00