JJF 1432-2013Calibration Specification for Medical Diagnostics X-Ray Non-Invasive Exposure Time Meters (English PDF)
医用诊断X射线非介入曝光时间表校准规范
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJF 1432-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
October 25, 2013
Implementation date
January 25, 2014
Scope
JJF 1432-2013 is the English-translated version of 医用诊断X射线非介入曝光时间表校准规范.
JJF 1432-2013 - This standard applies to: non-invasive medical diagnostic X-ray exposure schedule calibration.
Found what you need?
Document preview — JJF 1432-2013
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terminology and units of measurement (1)
- 3.1 Exposure Time (1)
- 3.2 Non-intrusive measurement (1)
1 Scope (1)
2 References (1)
3 Terminology and units of measurement (1)
3.1 Exposure Time (1)
3.2 Non-intrusive measurement (1)
Maximum peak voltage of 3.3 (1) the average peak voltage 3.4 (1)
3.5 Radiation detection limit (1)
4 Overview (1)
5 Metrological characteristics (2)
5.1 Exposure Time (2)
5.2 Working lower radiation (2)
Calibration Condition 6 (2)
6.1 Environmental conditions (2)
6.2 Standards and other measuring equipment (3)
6.3 Calibration preparation work (3)
7 Calibration items and calibration methods (4)
7.1 Appearance and function check (4)
7.2 Calibration method (4)
8 Expression, calibration results (6)
8.1 Calibration records (6)
8.2 Calibration process results (6)
9 Recalibration interval (6)
Information AX-ray tube voltage load curve Appendix (7) Appendix B Calibration original record format (recommended) (8) Appendix C Measurement of Uncertainty Evaluation (9)
Introduction
This specification based JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "Tong Metering term and definition of "establishment.
This specification reference JJG744-2004 "Medical Diagnostic X-ray radiation" on the exposure of non-intervention schedule Technical requirements, GB 9706.3-2000 "Medical electrical equipment - Part 2. X-ray diagnostic apparatus high incidence Voltage generator for safety requirements ", YY/T 0106-2008" diagnostic X-ray machine general technical conditions "in Loading time technical requirements, YY/T 0722-2009/(IEC 61676:2002, IDT) "Medical electrical equipment Preparation of diagnostic radiology for X-ray tube voltage non-access measuring dosimetric instruments "in the access type divider About the methods of measurement.
The specification for the first time to develop.
Non-invasive medical diagnostic X-ray exposure schedule Calibration Specification
1 Scope
This instruction applies to non-invasive medical diagnostic X-ray exposure calibration schedule.
2. References
These rules mainly cited the following documents.
JJG744-2004 diagnostic X-ray radiation GB 9706.3-2000 Medical electrical equipment - Part 2. diagnostic X-ray high voltage generator occurs Requirements for the safety device GB/T 10149-1988 X-ray equipment for medical terminology and symbols YY/T 0106-2008 medical diagnostic X-ray machine general technical conditions YY/T 0722-2009/(IEC 61676:2002, IDT) Medical electrical equipment in diagnostic radiology for X-ray tube voltage non-access measuring dosimetric instruments for dated references, only the dated edition applies to this rule; undated reference documents Member, the latest edition (including any amendments) apply to this rule.
3 terminology and units of measurement
3.1 Exposure time Also known as irradiation time, referring to the duration of the irradiation method prescribed measured X-ray machine, the radiation dose rate is usually Exceeds a predetermined level of the time.
NOTE. The exposure time is usually based on load time measurements obtained. Loading time is measured by the method specified anode input power Rate applied to the X-ray tube time. Usually refers to the first X-ray tube voltage rises to a peak of 75% until the final descent to the phase Stop time interval of equal value.
3.2 Non-intrusive measurement of non-invasivemeasurement Analysis of the emitted radiation X-ray tube voltage is measured by.
3.3 The maximum peak voltage the maximum value of the X-ray tube voltage within a specified time interval, the amount of volts (V).
3.4 the average peak voltage meanpeakvoltage Within a predetermined time interval the average of all X-ray tube voltage spikes, the amount of volts (V).
3.5 Radiation detection limit X-ray detector can accurately respond to minimum air kerma rate in units of cGy/min.
4 Overview
Non-intrusive medical X-ray exposure schedule, is used to measure X-ray machines for medical exposure time measuring instruments,
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJF 1432-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1432-2013
$225.00