JJF 1431-2013Calibration Specification of Magnetoelectricity Wind Sensor for Wind Farm (English PDF)
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for JJF 1431-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
JJF 1431-2013 (Calibration Specification of Magnetoelectricity Wind Sensor for Wind Farm) is available as an English-translated PDF.
JJF 1431-2013 — This standard specifies the use mayonnaise-in wind speed sensor (hereinafter referred to as the wind speed sensor) 3 m/s-30 m/s wind farm calibration range.
Found what you need?
Document preview — JJF 1431-2013
National Standard of the People's Republic of China
- ICS
- 17.100
- Classification
- A 53
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terminology and units of measurement (1)
- 3.1 The term (1)
- 3.2 Units of measurement (1)
- 4 Overview (1)
- 5 Metrological characteristics (1)
- 5.1 Measurement Error (1)
- 5.2 Repeatability (1)
- 5.3 Hysteresis (2)
1 Scope (1)
2 References (1)
3 Terminology and units of measurement (1)
3.1 The term (1)
3.2 Units of measurement (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 Measurement Error (1)
5.2 Repeatability (1)
5.3 Hysteresis (2)
Linear 5.4 (2)
Calibration Condition 6 (2)
6.1 Environmental conditions (2)
6.2 Measurement standards (2)
7 Calibration items and calibration methods (2)
7.1 Calibration items (2)
7.2 Calibration method (3)
7.3 Data Processing (4)
8 Expression, calibration results (7)
Calculating air density Appendix A (8) Winds from the magnetic-electric sensor calibration records (see format) (9) Appendix B Wind Farm Appendix C calibration certificate reference page format (11) Appendix D wind sensor measurement error Evaluation of Uncertainty Example (13)
Introduction
This specification based JJF 1071-2010 "national measurement calibration specifications write rules" written specification of general purpose in line with the amount of term JJF 1001-2011 "common measurement terms and definitions", uncertainty of measurement is given in Appendix Evaluation
Example based JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" in.
This specification metrological characteristics of repeatability, linearity and hysteresis are cited GB/T 18459-2001 "main sensor to define the calculation of static performance ", but because of the amount of wind speed in practice usually absolute amount, so the Specification metrological characteristics calibration results are given in absolute values for each parameter for each calibration point.
The specification range of the calibration and measurement characteristics Reference Technical indicators cited GB/T 18709-2002 "Wind Power Field wind resource measurement method "in the relevant parameters.
This specification is the first release.
Wind Farm wind speed sensor with magnetic Calibration Specification
1 Scope
This instruction applies to wind farms with wind speed magnetic sensor (hereinafter referred to as wind speed sensor) 3m/s ~ 30m/s Calibration range.
2. References
JJF 1001-2011 common measurement terms and definitions GB/T 7665-2005 sensor generic term GB/T 18459-2001 sensor is mainly static performance index calculation method GB/T 18709-2002 wind energy resource measurement method for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 terminology and units of measurement
3.1 Terms
3.1.1 Pitot probes pitot-statichead Pitot tube and static pressure hole Total hole where the measuring end.
3.1.2 blockage ratio Test section of the instrument (including mounting bracket) ratio of the area of the wind flow field uniformity test section of the cross-sectional area.
3.1.3 Flow field uniformity area uniformspaceofvelocity Within the test section in line with the uniformity of the flow rate and other technical indicators of the region.
3.2 units of measurement Winds from the sensor output frequency measurement unit Hertz, Hz.
4 Overview
Wind Farm wind speed magnetic-electric sensors are used to evaluate wind energy wind farm construction before. Winds from the main sensor package Including rotating part and the magnetic induction and the signal output section. In part by a rotation of 120 ° to each other trigeminal star bracket and Three hollow glass composition, the stent design of the rotary shaft and the center of the mounting bar (or sleeve). Magnetic induction and the signal output unit the main points include coils and permanent magnets. Under the impetus of the wind cup wind torsion torque is applied in turn, rotates relative to the magnet wire Revolutions, induced in the coil produces a continuous function of the wind speed of approximately sinusoidal signal.
5 Metrological characteristics
5.1 Measurement error
5.2 Repeatability
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
How to Download JJF 1431-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1431-2013
$295.00