JJF 1430-2013Calibration Specification for X-ray Timers (English PDF)

X射线计时器校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (14 pages)

Need quotation for your management?

Get a formal quotation for JJF 1430-2013 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

October 25, 2013

Implementation date

January 25, 2014

Scope

JJF 1430-2013 is the English-translated version of X射线计时器校准规范.

JJF 1430-2013 - This standard applies: There are electrical interfaces-x-ray timers calibration.

Found what you need?

Document preview — JJF 1430-2013

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terminology and units of measurement (1)

1 Scope (1)

2 References (1)

3 Terminology and units of measurement (1)

Irradiation time 3.1 (1)

3.2 Load Time (1)

3.3 Sensitivity (1)

4 Overview (2)

5 Metrological characteristics (2)

Interval 5.1 (2)

5.2 Pulse count (2)

5.3 Sensitivity (2)

Calibration Condition 6 (2)

6.1 Environmental conditions (2)

6.2 Standards and other measuring equipment (3)

7 Calibration items and calibration methods (4)

7.1 Visual inspection (4)

7.2 Electrical measurement calibration (4)

7.3 X-ray signal measurement calibration (5)

8 Calibration results expression (6)

9 Recalibration interval (7)

Appendix A calibration certificate page format (8)

Appendix B Measurement Uncertainty Evaluation (11)

Appendix C reference calibration methods (14)

Appendix D load signal sampling method (15)

Introduction

This specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment.

This specification reference to GB 9706.3-2000 "Medical electrical equipment - Part 2. Diagnostic X-ray generator the high-voltage generator for the safety requirements "and YY/T 0106-2008" diagnostic X-ray machine general technical conditions " the technical requirements and load time X-ray timers usually write specifications.

The specification for the first time to develop.

X-ray timer

1 Scope

This standard applies to electrical signal interface X-ray calibration timer.

2. References

This specification refers to the following documents.

GB 9706.3-2000 Medical electrical equipment - Part 2. High-voltage generator means of diagnostic X-ray generator Requirements for safety YY/T 0106-2008 medical diagnostic X-ray machine general technical conditions for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement 3.1 exposure time irradiationtime Also known as the irradiation time. The duration of the irradiation of X-ray machines, usually radiation dose rate exceeds a specified level Room, measuring in milliseconds, a unit symbol ms.

Note. the irradiation time is usually based on load time measurements obtained.

3.2 load time loadingtime the positive input power level is applied to the X-ray tube of the time. Usually refers to the first X-ray tube voltage rises to a peak 75% until last fall to the same time interval value only, units of measurement in milliseconds, a unit symbol ms.

Note.

1 For a tube or the X-ray tube by using a gate high voltage system load electronic switch control, when you load time can be played in accordance with the limit means limit means generates the load signal is terminated only when the load signal generated from the beginning Intervals to be determined.

2 For a high-voltage circuit in winding or in the X-ray tube filament heating circuit through the analog switch control loading system EC, the loading time can be in accordance with the first X-ray tube current rises to a peak of 25% last played under X-ray tube current A time interval to be determined only when reduced to the same value.

3.3 sensitivity X-ray timer can work and meet the requirements of the minimum measurement error in measuring signal values.

Note.

Minimum input signal amplitude peak to peak X-ray timer square wave, measuring sensitivity refers to a DC electric signal measurement mode ms in volts, unit symbol V;

2 AC electrical sensitivity refers to the input X-ray timer single-phase half-wave rectification or full-wave rectified signal pulse counting mode measurements RMS rectified before the same peak sinusoidal AC electrical signal measurement in volts, unit symbol V;

3 X-ray signal sensitivity ordered X-ray timer can work a minimum X-ray power, measured in units of kV, milli Ann, unit symbol kV, mA.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

How to Download JJF 1430-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1430-2013

$315.00