JJF 1426-2013Calibration Specification for Dynamic Parameters of Linear Accelerometer Used Double Centrifuge (English PDF)
双离心机法线加速度计动态特性校准规范
This is a limited preview
Buy now to download the full PDF (21 pages)
Need quotation for your management?
Get a formal quotation for JJF 1426-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
September 2, 2013
Implementation date
December 2, 2013
Scope
JJF 1426-2013 is the English-translated version of 双离心机法线加速度计动态特性校准规范.
JJF 1426-2013 - This standard applies to: the use of double centrifuge linear accelerometer dynamic characteristics calibration.
Found what you need?
Document preview — JJF 1426-2013
National Standard of the People's Republic of China
- ICS
- 17.080
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terms and Definitions (1)
- 4 Overview (1)
- 5 Metrological characteristics (2)
- 5.1 Frequency Characteristics (2)
- 5.2 Phase frequency characteristics (2)
- 5.3 Magnitude linearity (2)
1 Scope (1)
2 References (1)
3 Terms and Definitions (1)
4 Overview (1)
5 Metrological characteristics (2)
5.1 Frequency Characteristics (2)
5.2 Phase frequency characteristics (2)
5.3 Magnitude linearity (2)
Calibration Condition 6 (2)
6.1 Basic accelerometer is calibrated condition (2)
6.2 Environmental conditions (2)
6.3 Standards and other measuring equipment (3)
7 Calibration items and calibration methods (4)
7.1 Calibration preparation (4)
7.2 Calibration frequency characteristic (4)
7.3 Calibration phase frequency characteristics (5)
7.4 Magnitude linearity calibration (6)
8 Expression, calibration results (7)
9 Recalibration interval (7)
Appendix A sinusoidal acceleration based on the principle of double centrifuge (8)
B sensitivity of the accelerometer and the phase delay Appendix Measurement Uncertainty Example (10) Appendix C calibration original record format (15) Appendix D calibration certificate within the page format (17) Appendix E to determine the double centrifuge working radius (19) Appendix F accelerometer to determine the initial phase (25)
Introduction
This specification is a reference JJF 1116-2004 "linear accelerometer calibration precision centrifuge norms" on the basis of Proposed dual centrifuge line accelerometer dynamic calibration method. Calibration principles of the present specification is given, and the National International standards IEEE836-2009 "IEEE Recommended linear accelerometer sophisticated centrifuge test specifications" Appendix E Related Content match.
Double the normal accelerometer dynamic characteristics of centrifuges Calibration Specification
1 Scope
This standard applies to the use of the dynamic characteristics of double centrifuge line accelerometer calibration.
2. References
JJF 1116-2004 linear accelerometer calibration precision centrifuge specifications GJB585A-1998 inertial technology terms IEEE836-2009 IEEE Recommended linear accelerometer sophisticated centrifuge test specifications (IEEERecom-mendedPracticeforPrecisionCentrifugeTestingofLinearAccelerometers).
For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 Terms and Definitions GJB585A-1998 and established the following terms and definitions apply to this specification.
3.1 pairs centrifuge doublecentrifuge and from the main centrifuge centrifuges, which produces dynamic acceleration signal it can be used as input to the linear accelerometer Dynamic calibration. From the centrifuge mounted on the main dial or turn the centrifuge arm, and the rotating shaft of the main rotating centrifuge Parallel to the axis of rotation and at the same time generating a sinusoidal acceleration signal from the centrifuge through the primary centrifuge. Centrifuges used to achieve the main the magnitude of the acceleration signal from the centrifuge to achieve frequency and phase of the acceleration signal.
3.2 Sensitivity amplitudesensitivity Inspired by the sinusoidal acceleration signal, the accelerometer output signal line peak sinusoidal component input acceleration signal Peak ratio.
3.3 phase delay Inspired by the sinusoidal acceleration signal, linear accelerometer output signal of sinusoidal components of the input signal is sinusoidal acceleration Phase component.
3.4 magnitude linearity amplitudelinearity Characterization of accelerometer output signal line peak sinusoidal component with peak sinusoidal input signal change with the changes presented non Linear characteristic.
3.5 reference frequency Online accelerometer frequency amplitude linearity calibration in preference sinusoidal input acceleration signal.
4 Overview
General linear accelerometer (hereinafter referred to as "accelerometer") of the mechanical model is approximated as a typical mass-spring resistance Nepalese second order system mechanical model, see equation (1).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
How to Download JJF 1426-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1426-2013
$435.00