JJF 1417-2013Program of Pattern Evaluation of Impression Tonometers (English PDF)
压陷式眼压计型式评价大纲
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for JJF 1417-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
July 4, 2013
Implementation date
October 4, 2013
Scope
JJF 1417-2013 is the English-translated version of 压陷式眼压计型式评价大纲.
JJF 1417-2013 is the Chinese standard "Program of Pattern Evaluation of Impression Tonometers". Issued on 2013-07-04, in force from 2013-10-04.
Found what you need?
Document preview — JJF 1417-2013
National Standard of the People's Republic of China
- ICS
- 17.100
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Overview (1)
- 3.1 Purpose and principles (1)
- 3.2 Structure (1)
- 4 Legal management requirements (2)
- 4.1 Units of measurement requirements (2)
- 4.2 Legal metrology requirements for marking and identification of measuring instruments (2)
- 4.3 Offers the review of technical documents and test prototypes (2)
- 5 Measurement requirements (2)
- 5.1 Quality deviation (2)
- 5.2 Presser foot tube slide in performance (3)
- 5.3 Indication deviation (3)
- 6 General Requirements (3)
- 6.1 Appearance (3)
- 6.2 Zero to the positive deviation (4)
- 6.3 Basic size (4)
1 Scope (1)
2 References (1)
3 Overview (1)
3.1 Purpose and principles (1)
3.2 Structure (1)
4 Legal management requirements (2)
4.1 Units of measurement requirements (2)
4.2 Legal metrology requirements for marking and identification of measuring instruments (2)
4.3 Offers the review of technical documents and test prototypes (2)
5 Measurement requirements (2)
5.1 Quality deviation (2)
5.2 Presser foot tube slide in performance (3)
5.3 Indication deviation (3)
6 General Requirements (3)
6.1 Appearance (3)
6.2 Zero to the positive deviation (4)
6.3 Basic size (4)
The main parts of the surface roughness of 6.4 (4)
7 Types of evaluation items (4)
8 Pilot projects test methods and conditions (5)
8.1 Quality deviation (5)
8.2 Presser foot sliding performance in the tube (6)
8.3 Indication deviation (7)
8.4 Appearance (7)
8.5 Zero to the positive deviation (8)
8.6 Basic size (8)
The main parts of the surface roughness of 8.7 (9)
9 Type evaluation results to determine (9)
10 Original record format type evaluation (9)
Appendix A indentation tonometer type evaluation original record format (10)
Introduction
This specification based JJG574 "indentation tonometer", YY1036 "indentation tonometer" developed to JJF 1002 "national verification procedures write rules metering", JJF 1016 "Measuring Instruments type evaluation outline prepared guide Then ", JJF 1015" Measuring Instruments type evaluation and type approval of universal norms "together constitute the support of the norm-setting work as a basic series of documents.
This specification is the National Type Evaluation of an outline for the first time established. If the product or the ability to express technical indicators higher than the present syllabus Requirements, technical documents required in accordance with corporate standards, brochures and other verification.
Indentation tonometer type evaluation outline
1 Scope
This type of evaluation outline is applied indentation tonometer.
2. References
This outline references the following documents.
JJG574-2004 indentation tonometer YY1036-2004 indentation tonometer these documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated references, all subsequent amendments (not including errata content) or revisions do not apply to this syllabus, however, encourage the present Parties to study the outline agreement to use the latest versions of these documents. For undated reference documents, which the latest versions apply to this outline.
3 Overview
3.1 Purpose and principles Indentation tonometer intraocular pressure is a measure of the body of a special instrument. Its working principle is based on a certain quality of the indenter Corneal indentation depth is measured indirectly measured IOP values, each cell size of the scale is equivalent to 0.05mm Corneal indentation depth. Depending on the quality and value of the indentation depth of the indenter and weights, check conversion table to obtain IOP IOP.
3.2 configuration
Indentation tonometer by the scale ruler, frame pointer, hammer bow, additional weights, fixed weight, pressure needle, feet Composition pipe and hold handles, etc. Part 9 (Fig. 1). Presser foot move up and down in the tube, press the upper portion of the needle tip was like, it A certain arc hammer bow contacts, formed a pointer deflection displacement transmission mechanism.
1- scale ruler; 2- stent; 3- pointer; 4- hammer bow;
5- Additional weights; 6- fixed weight; 7- presser; 8- foot pipe; 9- holding handle
Figure 1 schematic indentation tonometer
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJF 1417-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1417-2013
$255.00