JJF 1412-2013Calibration Specification for Clinical Color Change Thermometers (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (11 pages)

Need quotation for your management?

Get a formal quotation for JJF 1412-2013 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

JJF 1412-2013 (Calibration Specification for Clinical Color Change Thermometers) is available as an English-translated PDF.

JJF 1412-2013 — This standard applies to: measurement range of 35. 5°C ~ 42. 0°C for measuring body temperature clinical thermometer with discoloration (hereinafter referred to as the thermometer) calibration.

Found what you need?

Document preview — JJF 1412-2013

National Standard of the People's Republic of China

ICS
17.200
Classification
A 54

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terms (1)
  • 3.1 Discoloration thermometer (1)
  • 3.2 Reusable thermometers (1)
  • 3.3 Disposable thermometer (1)
  • 3.4 Temperature compensation value (1)
  • 3.5 Pre-tune thermometer (1)
  • 3.6 Temperature point (1)
  • 3.7 Temperature region (2)
  • 3.8 Measurement time (2)
  • 3.9 Retention time (2)
  • 3.10 Expiration Date (2)
  • 4 Overview (2)
  • 5 Metrological characteristics (2)
  • 5.1 Temperature range (2)
  • 5.2 Division value (2)
  • 5.3 Retention time (2)
  • 5.4 Indication error (2)
  • 6 Calibration conditions (3)

1 Scope (1)

2 References (1)

3 Terms (1)

3.1 Discoloration thermometer (1)

3.2 Reusable thermometers (1)

3.3 Disposable thermometer (1)

3.4 Temperature compensation value (1)

3.5 Pre-tune thermometer (1)

3.6 Temperature point (1)

3.7 Temperature region (2)

3.8 Measurement time (2)

3.9 Retention time (2)

3.10 Expiration Date (2)

4 Overview (2)

5 Metrological characteristics (2)

5.1 Temperature range (2)

5.2 Division value (2)

5.3 Retention time (2)

5.4 Indication error (2)

6 Calibration conditions (3)

Environmental conditions 6.1 (3)

6.2 Measurement standard equipment and ancillary equipment (3)

7 Calibration items and calibration methods (3)

7.1 Calibration items (3)

7.2 Calibration method (3)

7.3 Calibration process results (4)

8 Expression, calibration results (4)

9 Recalibration interval (5)

Appendix A clinical thermometer with color calibration original records (6)

Appendix B clinical thermometer calibration certificate with color (inside) format (7)

Appendix C thermostatic bath thermometer placed in the calibration method of operation (8)

Appendix D clinical thermometer with color measurement results Uncertainty Evaluation (9)

Introduction

This specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment, where the measurement is not Evaluation is based on degree of certainty JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" in.

This specification metrological characteristics of the temperature range, dividing the value, retention time and indication errors were cited EN12470-2.

2000 A1.2009 "clinical thermometer Part 2 phase change type (dot matrix) thermometers" [Clinicalther-mometers-Part 2. Phasechangetype (dotmatrix) thermometers] in 5,6.1,6.2 and 6.5.

This specification calibration conditions in ambient temperature reference ASTME825-98 (Reapproved2009) "to make a one-time Intermittent measuring body temperature thermometer using phase-change "(PhaseChange-TypeDisposableFeverTher-mometerforIntermittentDeterminationofHumanTemperature) of 5.5 and ASTM E1299-96 (Reapproved2010) "Reusable intermittently measuring body temperature phase change type thermometer" (ReusablePhase-Change-TypeFeverThermometerforIntermittentDeterminationof HumanTemperature) of 5.5.

EN12470-2:2000 A1.2009 measured as specified in ASTM E 825-98 covers (Reapproved2009) and ASTME1299-96 (Reapproved2010) specified measurement range, more in line with the actual situation.

The specification for the first time to develop.

Clinical thermometer calibration with color specification

1 Scope

This standard applies to the measurement in the range of 35.5 °C ~ 42.0 °C for measuring body temperature with a color clinical thermometer (Hereinafter referred to as a thermometer) calibration.

2. References

This specification references the following documents.

EN12470-2:2000 A1.2009 Clinical thermometers - Part 2 with a phase change type (dot) temperature Meter [Clinicalthermometers-Part 2. Phasechangetype (dotmatrix) thermometers] ASTME825-98 (Reapproved2009) disposable intermittent measuring body temperature of a phase change type body Thermometer (PhaseChange-TypeDisposableFeverThermometerforIntermittentDetermina-tionofHumanTemperature) ASTME1299-96 (Reapproved2010) reusable intermittently measuring the body temperature of a phase-change Thermometer (ReusablePhase-Change-TypeFeverThermometerforIntermittentDetermi-nationofHumanTemperature) for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 Terms

3.1 discoloration thermometer colorchangethermometer Using a series of temperature-sensitive color change point status indicator to measure the temperature of the thermometer.

3.2 reusable thermometer You can use many of the thermometer.

Note. a maximum limit frequency of use.

3.3 Disposable thermometer Use a thermometer to waste.

Note. The storage temperature not higher than the lower limit of the measurement range.

3.4 Temperature compensation value temperatureoffset Temperature correction amount from the actual value and the thermometer shows the temperature of the reasons for compensating thermal conduction caused provided.

[EN12470-2:2000 A1.2009 3.5] Note. The thermometer in the measurement range, only a uniform temperature compensation value.

3.5 Pre-tune thermometer preadjustedthermometer Thermometer having temperature compensation value. [EN12470-2:2000 A1.2009 3.6] 3.6 temperature point temperaturedot Spherical capsules small clinical thermometer on the different chemical composition of the mixture having a specific color temperature.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.

How to Download JJF 1412-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
11 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1412-2013

$255.00