JJF 1410-2013Calibration Specification for Dynamical Screw Travel Testers (English PDF)
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for JJF 1410-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
JJF 1410-2013 (Calibration Specification for Dynamical Screw Travel Testers) is available as an English-translated PDF.
JJF 1410-2013 — This standard applies: Dynamic Travel screw gauge calibration.
Found what you need?
Document preview — JJF 1410-2013
National Standard of the People's Republic of China
- ICS
- 17.040
- Classification
- A 52
- Replacing
- JJG 671-1990
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terms (1)
- 3.1 Target stroke ls (1)
- 3.2 The actual average travel lm (1)
- 3.3 Effective stroke lu (1)
- 3.4 The actual mean travel deviation e0a or esa (1)
1 Scope (1)
2 References (1)
3 Terms (1)
3.1 Target stroke ls (1)
3.2 The actual average travel lm (1)
3.3 Effective stroke lu (1)
3.4 The actual mean travel deviation e0a or esa (1) Stroke variation amount of 3.5 V (1)
4 Overview (1)
5 Metrological characteristics (3)
5.1 Rotating head frame to the top of the rotation error (3)
5.2 Probe frame motion straightness (3)
5.3 Frame/tailstock connection with the parallelism of the main rail (3)
5.4 Rack movement direction of the direction of movement of the probe frame of parallelism (3)
5.5 Stroke indication error (3)
Reproducibility 5.6 Comprehensive measurements (3)
6 Calibration conditions (3)
Environmental conditions 6.1 (3)
6.2 Calibration equipment (3)
7 Calibration items and calibration methods (4)
7.1 General Inspection (4)
7.2 Calibration items and methods (4)
8 Calibration results expression (8)
9 Recalibration interval (8)
Appendix A sample uncertainty analysis (9)
Appendix B ball screw stroke deviation and changes in scale (11)
Introduction
This specification is mainly based on the standard GB/T 17587.1-1998eqvISO 3408-3.1992 "Ball Deputy Part 1. Terminology and Symbols ", GB/T 17587.3-1998eqvISO 3408-3.1992" Ball Vice - Part 3. Acceptance conditions and acceptance tests. " the specification for the revision, instead of JJG671-1990 "screw dynamic measuring instrument." Dynamic measuring instrument from the screw stroke the principle and function of departure, redefined the metrological characteristics of the portfolio, including.
--- Probe frame motion instead of straightness in horizontal and vertical straightness when the movable table;
--- Probe head frame motion frame/tailstock parallel connection of the head frame/flat tailstock connection with the primary rail Tailstock and a line of direction of movement of the direction of movement of the probe frame of two parallel composition metrological characteristics, instead of the head frame spindle taper Axis of the hole and tailstock sleeve taper from the center line of the table moving rail difference value, the centerline of the headstock spindle taper Parallelism with the table moving direction, tailstock sleeve taper parallel to the center line of the moving direction of the table and so on;
--- Stroke indication error instead of the x-axis is moved around the table, swing y-axis and z-axis;
Integrated measurement reproducibility --- instead of a multiple installation measurement repeatability and reproducibility of measurements multiple installations.
Standards and calibration methods have also been adjusted accordingly.
JJG671-1990 for the first release.
Screw Dynamic Travel gauge calibration specification
1 Scope
This instruction applies to Screw Dynamic Travel meter calibration.
2. References
This specification refers to the following documents.
JJF 1071 National Calibration Specifications writing rules the first part of the 1991 ball screw 1.. GB/T 17587.1-1998eqvISO 3408-1 and terminology symbol Part 1992 Ball screws 3.. GB/T 17587.3-1998eqvISO 3408-3 and acceptance conditions Acceptance inspection for dated references, only the dated edition applies to this rule; undated reference documents Member, the latest edition (including amendments) apply to this rule.
3 Terms
Terms and definitions GB/T 17587.1-1998 defined apply to this specification.
3.1 target stroke ls specifiedtravel [GB/T 17587.1-19983.2.4.5} Goal lead with the rotation number of turns of the product.
Note. Sometimes the nominal target stroke by stroke and stroke compensation values.
3.2 The actual average travel lm actualmeantravel [GB/T 17587.1-19983.2.4.7} Having a minimum of actual travel straightness deviation line.
3.3 effective stroke lu usefultravel [GB/T 17587.1-19983.2.4.8} Has designated precision stroke portion (ie, travel plus the length of the ball nut body).
3.4 The actual mean travel deviation e0a or esa actualmeantraveldeviatione0aoresa {GB/T 17587.1-19983.2.5.3] in the effective stroke, the actual average travel itinerary lm nominal difference of l0 or actual average travel lm target Ls the difference between the stroke.
3.5 V travelvariation stroke volume variation [GB/T 17587.1-19983.2.6} Parallel to the actual mean travel lm and the actual value of the bandwidth inclusive trip curve.
Note. The amount of change in itinerary has been provided. 2pi radian stroke and corresponding bandwidth value V2pi; 300mm travel with relative bandwidth V300 Correspondence; effective stroke bandwidth values Vu, respectively.
Note. The above bandwidth allowed bandwidth (symbol is "p") and the actual bandwidth (symbol "a") of the difference.
For example. within 300mm stroke length allows bandwidth V300p; actual bandwidth efficient travel within the Vua.
4 Overview
Screw Dynamic Travel meter (hereinafter referred to as the screw measuring instrument) is a measure of the quality of the screw stroke equipment, measuring wire
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJF 1410-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1410-2013
$255.00