JJF 1407-2013Calibration Specification for Thermometers of WBGT-index Meters (English PDF)
WBGT指数仪温度计校准规范
This is a limited preview
Buy now to download the full PDF (13 pages)
Need quotation for your management?
Get a formal quotation for JJF 1407-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
May 13, 2013
Implementation date
August 13, 2013
Scope
JJF 1407-2013 is the English-translated version of WBGT指数仪温度计校准规范.
JJF 1407-2013 - This standard applies to WBGT index meter thermometer calibration. WBGT index meter including natural wet bulb thermometer, black bulb thermometer and a dry bulb thermometer.
Found what you need?
Document preview — JJF 1407-2013
National Standard of the People's Republic of China
- ICS
- 17.200
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Terms and definitions (1)
- 3.1 WBGT index (1)
- 3.2 WBGT Index instrument thermometer (1)
- 3.3 Thermal load (1)
- 3.4 Effective area (1)
- 4 Overview (1)
- 5 Metrological characteristics (2)
1 Scope (1)
2 References (1)
3 Terms and definitions (1)
3.1 WBGT index (1)
3.2 WBGT Index instrument thermometer (1)
3.3 Thermal load (1)
3.4 Effective area (1)
4 Overview (1)
5 Metrological characteristics (2)
Calibration Condition 6 (2)
6.1 Environmental conditions (2)
6.2 Standard device and ancillary equipment (3)
7 Calibration items and calibration methods (3)
7.1 Calibration items (3)
7.2 Calibration method (3)
8 Calibration results expression (5)
9 Recalibration interval (5)
Appendix A WBGT Index instrument thermometer calibration original record format (6)
Appendix B Calibration Certificate page format (7)
Appendix C measurement (indication error) Uncertainty evaluation of a sample (8)
Appendix D measurements (indication error) Uncertainty Evaluation of Example Two (11)
Introduction
This specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment, where measurement uncertainty Evaluation of in accordance JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" in.
The specification for the first time to develop.
WBGT Index instrument thermometer calibration specification
1 Scope
This instruction applies to WBGT Index instrument thermometer calibration. WBGT Index instrument, including natural wet bulb thermometer Meter, the black bulb thermometer and dry bulb thermometer. Natural wet bulb thermometer measuring range. 5 °C ~ 40 °C; black-bulb temperature Meter measuring range. 20 °C ~ 120 °C; dry bulb thermometer measuring range. 10 °C ~ 60 °C.
2. References
This specification refers to the following documents.
JJG205-2005 mechanical hygrometer GB/T 4200-2008 hot job classification GB/T 17244-1998 thermal environment based on WBGT index (wet bulb globe temperature) of the thermal load workers Evaluation charge for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 Terms and definitions
3.1 WBGT index WBGT-index Also known as the wet bulb, black bulb temperature, is a comprehensive evaluation of the basic parameters of human exposure to the operating environment of the thermal load, single Bit °C. [GB/T 4200-2008,3.4]
3.2 WBGT Index instrument thermometer thermometerofWBGT-indexmeter WBGT Index instrument measuring natural wet bulb temperature, globe temperature, dry bulb temperature of the thermometer.
3.3 heat load heatstress the extent of the human body heat when operating in a hot environment to WBGT index, said heat depends on manual labor and the amount of heat exchange between the environment and human characteristics. [GB/T 17244-1998,2.2] 3.4 effective area Meet the appropriate space temperature fluctuation and uniformity required in an incubator, or product specification prescribed area.
4 Overview
WBGT index is a basic parameter of human exposure to environmental heat load. WBGT Index instrument were measured Natural wet bulb temperature, globe temperature, dry bulb temperature and the three parameters, then get WBGT index calculated by the formula.
WBGT Index instrument usually consists of a temperature sensor and instrument host of two parts, natural wet bulb temperature, black ball temperature and dry-bulb temperature of the three sensors mounted on the same bracket, there are two connections and a direct connection by measuring cable Forms. FIG. 1 (a) and 1 (b) below.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.
How to Download JJF 1407-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1407-2013
$255.00