JJF 1402-2013Calibration Specification for Biological Microscopes (English PDF)
生物显微镜校准规范
This is a limited preview
Buy now to download the full PDF (11 pages)
Need quotation for your management?
Get a formal quotation for JJF 1402-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
April 27, 2013
Implementation date
July 27, 2013
Scope
JJF 1402-2013 is the English-translated version of 生物显微镜校准规范.
JJF 1402-2013 - This standard applies to: Biological microscope calibration.
Found what you need?
Document preview — JJF 1402-2013
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Overview (1)
- 4 Metrological characteristics (2)
- 4.1 Microscope objective magnification error (2)
- 4.2 Binocular microscope system magnification difference of about two (2)
- 4.3 Binocular microscope field of view around the center of the deviation (2)
- 4.4 Indication error (2)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Metrological characteristics (2)
4.1 Microscope objective magnification error (2)
4.2 Binocular microscope system magnification difference of about two (2)
4.3 Binocular microscope field of view around the center of the deviation (2)
4.4 Indication error (2)
Calibration Condition 5 (2)
5.1 Environmental conditions (2)
5.2 Calibration with standard equipment and the appropriate equipment (2)
6 Calibration items and calibration methods (2)
6.1 Calibration items (2)
6.2 Calibration method (3)
7 Calibration Results The expression (4)
8 Recalibration interval (5)
Appendix A Error in Measurement Uncertainty Evaluation (6)
Appendix B microscope objective magnification error measuring results Evaluation of Uncertainty (8)
Appendix C calibration certificate content and in-page format (10)
Introduction
JJF 1402-2013 "biological microscope calibration specification" (hereinafter referred to as "the Rules") for biological microscopes Calibration measurement established technical specifications. Preparation of this specification to JJF 1071-2010 "national measurement calibration specifications prepared by Regulation Then ", JJF 1001-2011" common measurement terms and definitions "and JJF 1059.1-2012" Measurement Uncertainty assessment and given that "as the basis and foundation. This specification is the main reference standard GB/T 2985-2008 "biological microscope." this specification is the first release.
Biological microscope calibration specifications
1 Scope
This standard applies to biological microscope calibration.
2. References
This specification references the following documents.
GB/T 2985-2008 Microscope for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 Overview
Microscope (hereinafter referred to as the "microscope") is an observation and measurement of biological chips, biological cells, bacteria Measuring the size of the structure, as well as for the living tissue culture, liquid precipitation amount, powder and fine particles size and other parameters the amount of the instrument. Mainly by the eyepiece, an objective lens, a stage and a mirror (or built-in light and a condenser lens), etc., have Microscope with an illumination portion (condenser), replace the role of the reflector.
When used, the object to be measured on the microscope stage, adjust the position of the stage by focusing hand wheel, make things Body microscope eyepiece reticle into a clear image, in order to observe and measure.
Structured into microscope monocular microscope and binocular microscope use is divided into universal microscope, laboratory and research Study with a microscope. Specific structure shown in Figure 1, Figure 2.
Figure 1 monocular microscope structure Figure 2 binocular microscope Chart
1- eyepiece; 2- eyepiece; 3- nosepiece and the objective lens; 4- stage;
5- lighting or mirror; 6- focusing hand wheel 1- eyepiece; 2- eyepiece; 3- nosepiece and the objective lens; 4- stage;
5- lighting or mirror; 6- move the stage button; 7- focusing hand wheel
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 11 pages — is available in the English PDF.
How to Download JJF 1402-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1402-2013
$255.00