JJF 1397-2013Galibration Specification for Electrostatic Discharge Simulators (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for JJF 1397-2013 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

JJF 1397-2013 (Galibration Specification for Electrostatic Discharge Simulators) is available as an English-translated PDF.

JJF 1397-2013 — This standard applies pursuant to GB/T 17626. 2 "electromagnetic compatibility test and measurement techniques-Electrostatic discharge immunity test" and IEC 61000-4-2-2008 "EMC (Electromagnetic compatibility (EMC).

Found what you need?

Document preview — JJF 1397-2013

National Standard of the People's Republic of China

ICS
17.220
Classification
A 56

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terms (1)
  • 3.1 Hold Time (1)
  • 3.2 Transfer impedance (1)
  • 4 Overview (1)
  • 4.1 ESD simulator uses (1)
  • 4.2 Structure ESD simulator (2)
  • 5 Metrological characteristics (2)
  • 5.1 Output voltage (2)
  • 5.2 Contact discharge current (2)
  • 6 Calibration conditions (3)

1 Scope (1)

2 References (1)

3 Terms (1)

3.1 Hold Time (1)

3.2 Transfer impedance (1)

4 Overview (1)

4.1 ESD simulator uses (1)

4.2 Structure ESD simulator (2)

5 Metrological characteristics (2)

5.1 Output voltage (2)

5.2 Contact discharge current (2)

6 Calibration conditions (3)

Environmental conditions 6.1 (3)

6.2 Calibration equipment (3)

7 Calibration items and calibration methods (4)

7.1 General inspection (4)

7.2 Calibration method (4)

8 Calibration results expression (6)

9 Recalibration interval (6)

Original record format in Appendix A (7) Appendix B Calibration Certificate page format (8) Appendix C Evaluation of Uncertainty Example (10)

Introduction

The calibration specification is based on GB/T 17626.2 "Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity Tests "and IEC 61000-4-2:2008" Electromagnetic compatibility - Testing and measurement techniques Electrostatic discharge immunity test " (Electromagneticcompatibility (EMC) -Part 4-2. Testingandmeasurementtechniques-Electrostaticdischargeimmunitytest) calibration requirements for ESD simulator compiled.

This specification is the first release.

ESD simulator calibration specification

1 Scope

This specification applies according to GB/T 17626.2 "Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity Tests "and IEC 61000-4-2:2008" Electromagnetic compatibility - Testing and measurement techniques Electrostatic discharge immunity test " (Electromagneticcompatibility (EMC) -Part 4-2. Testingandmeasurementtechniques-the instrument was calibrated Electrostaticdischargeimmunitytest) electrostatic discharge simulator requirements, other types ESD simulator implementation.

2. References

This specification refers to the following documents.

GB/T 4365-2003 Electrotechnical terminology Electromagnetic compatibility (idtIEC 60050 (161).1990) GB/T 17626.2 electromagnetic compatibility test and measurement techniques - Electrostatic discharge immunity test IEC 61000-4-2:2008 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (Elec-tromagneticcompatibility (EMC) -Part 4-2. Testingandmeasurementtechniques-Electrostaticdischargeimmunitytest) for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 Terms

3.1 holding time Prior to discharge, leaving the test voltage drop due to leakage of not more than 10% of the time interval.

3.2 Transfer impedance transferimpendence ESD target - Attenuator - defined transfer impedance of the cable is injected into the current and the current output target input Voltage precision than 50ohm load (the precise load is placed at one end of the cable, replace the oscilloscope load).

Note. ESD simulator calibration procedure, if the current Isys injected onto the target, then the oscilloscope displays a voltage Vosc. In order to use the current display voltage to calculate the unknown, we need to determine the low-frequency transfer impedance. Low-frequency transfer impedance can pass Determined through the following steps.

- In the front-end electrostatic discharge target injection 1A DC current Isys. The front end of the current target is to discharge that side.

- In the cable end and the connection end of the oscilloscope, connect a 50ohm load precision. 50ohm load tolerance of ± 1%.

- voltage V50 measurement precision 50ohm load.

The transfer impedance. Zsys = V50 Isys

4 Overview

4.1 ESD Simulator uses

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

How to Download JJF 1397-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1397-2013

$255.00