JJF 1395-2013Calibration Specification for Audio Analyzer (English PDF)
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for JJF 1395-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
JJF 1395-2013 (Calibration Specification for Audio Analyzer) is available as an English-translated PDF.
JJF 1395-2013 — This standard applies to the frequency range of 10 Hz ~ 200 kHz of new manufacturing, audio analyzer calibration and repair after use.
Found what you need?
Document preview — JJF 1395-2013
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 56
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Overview (1)
- 4 Metrological characteristics (1)
- 4.1 Audio signal analyzing section (1)
- 4.2 Audio signal generating portion (1)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Metrological characteristics (1)
4.1 Audio signal analyzing section (1)
4.2 Audio signal generating portion (1)
Calibration Condition 5 (2)
5.1 Environmental conditions (2)
5.2 Calibration Equipment (2)
6 Calibration items and calibration methods (3)
6.1 Appearance and working properly check (3)
6.2 Audio calibration signal analysis section (3)
6.3 Calibration section of the audio signal generation (6)
7 Calibration Results The expression (8)
8 Recalibration interval (9)
Appendix A calibration record format (10)
Appendix B Calibration Certificate-page format (14)
Appendix C Evaluation of Uncertainty Example (18)
Introduction
The calibration specification based JJF 1071-2010 "National Calibration Specifications writing rules" establishment.
The specification for the 10Hz ~ 200kHz audio analyzer calibration method, respectively, from the audio signal analysis section and Performed for a predetermined portion of the audio signal occurs in two ways. Audio signal analysis section of the calibration include. frequency measurement, AC voltage measuring intrinsic noise, measuring AC voltage, AC voltage measurement frequency of the additional error distortion measure residual loss True distortion measure; the audio signal generating portion of the calibration include. output frequency, output voltage, output voltage Frequency response, distortion sine wave output. And gives the AC voltage measurement in the appendix, distortion measure other items Objective evaluation of measurement uncertainty method example.
This specification is the first release.
Audio Analyzer Calibration Specification
1 Scope
This calibration new specification applies to the frequency range of 10Hz ~ 200kHz in manufacturing, use and repair of audio post Analyzer calibration.
2. References
This specification references the following documents.
JJF 1071-2010 National Calibration Specifications writing rules for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.
3 Overview
Audio analyzer commonly used in audio amplifiers, filters, cell phone transmission characteristics such as performance testing. Audio Analyzer Section and audio signal analysis components typically occurs by the audio signal. Audio signal generation portion may object to be measured mention for 1 to 2 road test excitation signal; an audio signal analysis section for receiving the object to be measured output of the audio signal, and its comprehensive measurement of total harmonic distortion, voltage amplitude, frequency and other parameters analyzed.
Audio analyzer audio signal generating portion of the output signal frequency is usually in the range 10Hz ~ 200kHz, sound Frequency signal analysis section generally measure the frequency, voltage, total harmonic distortion and other parameters within the frequency range of the signal.
4 Metrological characteristics 4.1 audio signal analysis section
4.1.1 Frequency Measurement
4.1.1.1 Measuring range. 10Hz ~ 200kHz;
4.1.1.2 The maximum permissible error. ± (0.005% ~ 0.3%).
4.1.2 AC voltage measurement
4.1.2.1 Measuring range. 1mV ~ 300V (10Hz ~ 200kHz);
4.1.2.2 The maximum permissible error. ± (0.5% ~ 5%) (1kHz);
4.1.2.3 additional error frequency (1kHz reference). ± (2% ~ 10%) (10Hz ~ 200kHz);
4.1.3 Voltage measurement inherent noise. <=50µV (20kHzBW).
4.1.4 Distortion Measurement
4.1.4.1 Measuring range. (0.01% ~ 100%) (10Hz ~ 200kHz);
4.1.4.2 The maximum permissible error. ± (5% ~ 20%).
4.1.5 distortion measure residual distortion. <= (0.003% ~ 0.05%) (10Hz ~ 200kHz).
4.2 audio signal generation section
4.2.1 Output frequency
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
How to Download JJF 1395-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1395-2013
$375.00