JJF 1393-2013Program of Pattern Evaluation of Electrocardiographic Monitors (English PDF)
心电监护仪型式评价大纲
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for JJF 1393-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
February 16, 2013
Implementation date
May 16, 2013
Scope
JJF 1393-2013 is the English-translated version of 心电监护仪型式评价大纲.
JJF 1393-2013 is the Chinese standard "Program of Pattern Evaluation of Electrocardiographic Monitors". Issued on 2013-02-16, in force from 2013-05-16.
Found what you need?
Document preview — JJF 1393-2013
National Standard of the People's Republic of China
- ICS
- 17.220
Contents
- Introduction (II)
- 1 Scope (1)
- 2. References (1)
- 3 Overview (1)
- 4 Legal management requirements (1)
- 4.1 Units of measurement requirements (1)
- 4.2 Legal metrology requirements for marking and identification of measuring instruments (1)
- 4.3 Other requirements (2)
- 5 Measurement requirements (2)
- 5.1 ECG display section (2)
- 5.2 Heart rate display section (2)
- 6 General Requirements (2)
- 6.1 Appearance and work of (2)
- 6.2 Functional requirements (3)
- 6.3 Climate requirements (3)
- 6.4 Mechanical environmental requirements (3)
- 6.5 Power adaptability (3)
- 6.6 EMC requirements (3)
- 7 Type evaluation item list (3)
- 8 Type evaluation test methods and conditions (4)
- 8.1 Legal Requirements management inspection (4)
- 8.2 Metrological performance test (4)
- 8.3 General technical requirements for test (8)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Legal management requirements (1)
4.1 Units of measurement requirements (1)
4.2 Legal metrology requirements for marking and identification of measuring instruments (1)
4.3 Other requirements (2)
5 Measurement requirements (2)
5.1 ECG display section (2)
5.2 Heart rate display section (2)
6 General Requirements (2)
6.1 Appearance and work of (2)
6.2 Functional requirements (3)
6.3 Climate requirements (3)
6.4 Mechanical environmental requirements (3)
6.5 Power adaptability (3)
6.6 EMC requirements (3)
7 Type evaluation item list (3)
8 Type evaluation test methods and conditions (4)
8.1 Legal Requirements management inspection (4)
8.2 Metrological performance test (4)
8.3 General technical requirements for test (8)
9 Type, Judgment principle results (20)
Appendix A ECG pattern evaluation original records (21)
Introduction
This outline is intended to provide the technical basis for a complete ECG pattern evaluation. This outline is based JJF 1015-2002 "Measuring Instruments type evaluation and type approval of universal norms" and JJF 1016-2009 "Measuring Instruments type evaluation Outline guidelines for the preparation, "written and major references, and reference the following documents.
JJG760-2003 ECG
GB/T 14710-2009 medical electrical environmental requirements and test methods GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test GB/T 17626.11-2008 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage Variations immunity tests this outline is the first release.
ECG pattern evaluation outline
1 Scope
This type of evaluation framework applicable to ECG (including multi-parameter monitor ECG monitoring section and cardiac defibrillators Care instrument ECG monitoring section) of the type evaluation.
2. References
This outline references the following documents.
JJG760-2003 ECG
GB/T 14710-2009 medical electrical environmental requirements and test methods GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test GB/T 17626.11-2008 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage Variations immunity tests these documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents Members, release date only applies to this outline. For undated references, the latest edition (including all Amendments) apply to this outline.
3 Overview
ECG (hereinafter referred to as the monitor) is a human ECG, heart rate monitoring and dynamic measuring instrumentation.
According to the structure and function can be divided into the following four types. ECG display type, display type ECG heart rate, electrocardiogram Type display records, display ECG heart rate and ECG recording type.
4 legal management requirements 4.1 units of measurement requirements Measuring instruments shall be the legal units of measurement.
4.2 With regard to legal metrology marking and identification requirements for measuring instruments Measuring instruments must nameplate or panel, table top clear part of legal metrology marking and labeling standard measuring instruments Knowledge, its marks, logos and instructions must be clear, solid and reliable.
4.2.1 legal metrology signs generally include the following
--- Measurement equipment manufacturing license logo and number (test prototype should stay out of the corresponding position);
--- Measurement equipment type approval mark and number (test prototype may be left out of the corresponding position; this item is not mandatory Provisions);
--- Product quality stamps certificate (this can be provided separately from the body and measuring instruments).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
How to Download JJF 1393-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1393-2013
$435.00