JJF 1392-2013Program of Pattern Evaluation of Ambulatory Electrocardiographs (English PDF)
This is a limited preview
Buy now to download the full PDF (25 pages)
Need quotation for your management?
Get a formal quotation for JJF 1392-2013 in 30 minutes.
Issued by
Xue Li Yong (General Logistics Department of the Ministry of Health Drug and Instrument Control)
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
JJF 1392-2013 (Program of Pattern Evaluation of Ambulatory Electrocardiographs) is available as an English-translated PDF.
JJF 1392-2013 — This standard applies to the following two types of dynamic (moving) pattern evaluation ECG machine: a) continuous recording, analysis of ECG and achieve full playback.
Found what you need?
Document preview — JJF 1392-2013
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 56
Issued by: Xue Li Yong (General Logistics Department of the Ministry of Health Drug and Instrument Control)
Contents
- Introduction (III)
- 1 Scope (1)
- 2. References (1)
- 3 Overview (1)
- 4 Legal management requirements (2)
- 4.1 Units of measurement requirements (2)
- 4.2 Legal metrology requirements for marking and identification of measuring instruments (2)
- 4.3 Other requirements (2)
- 5 Measurement requirements (2)
- 5.1 Maximum input range (2)
- 5.2 Tracings minimum sensitivity threshold (2)
- 5.3 Resistance polarization voltage (2)
- 5.4 Input impedance (2)
- 5.5 Sensitivity error (2)
- 5.6 Sensitivity stability (2)
- 5.7 Calibration voltage (applies only to analog memory device to be examined) (2)
- 5.8 Frequency Response (3)
- 5.9 Overshoot (3)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Legal management requirements (2)
4.1 Units of measurement requirements (2)
4.2 Legal metrology requirements for marking and identification of measuring instruments (2)
4.3 Other requirements (2)
5 Measurement requirements (2)
5.1 Maximum input range (2)
5.2 Tracings minimum sensitivity threshold (2)
5.3 Resistance polarization voltage (2)
5.4 Input impedance (2)
5.5 Sensitivity error (2)
5.6 Sensitivity stability (2)
5.7 Calibration voltage (applies only to analog memory device to be examined) (2)
5.8 Frequency Response (3)
5.9 Overshoot (3)
Hysteresis 5.10 (3)
5.11 timing error (only applicable to the event insertion means to be examined on a recorder) (3)
5.12 Hard copy (printout or photo) tracings speed error (3)
Interference between 5.13 (3)
5.14 Common mode rejection ratio (3)
5.15 System noise level (3)
5.16 Compliance and pacing pulse detection capability (3)
6 General Requirements (3)
6.1 Appearance and work of (3)
6.2 Climate requirements (4)
6.3 Mechanical environmental requirements (4)
6.4 Power adaptability (4)
6.5 EMC requirements (4)
7 Type evaluation item list (4)
8 Type evaluation test methods and conditions (5)
8.1 Legal Requirements Management (5)
8.2 Metrological requirements (5)
8.3, and appearance check work (15)
8.4 Climate Environmental Testing (15)
8.5 Mechanical environmental testing (16)
8.6 Power adaptability test (16)
8.7 Electromagnetic compatibility tests (17)
9 Type, Judgment principle results (25)
Appendix A dynamic (movable) ECG machine type evaluation original record format (26)
Introduction
This outline is dynamic (movable) ECG machine type evaluation basis.
The preparation of the outline to JJG1042-2008 "dynamic (movable) ECG machine", GB/T 14710-2009 "Medical electrical environmental requirements and test methods", GB/T 17626.2-2006 "Electromagnetic compatibility - Testing and measurement techniques Electrostatic discharge immunity test ", GB/T 17626.4-2008" Electromagnetic compatibility - Testing and measurement techniques - Electrical fast Transient burst immunity test ", GB/T 17626.5-2008" Electromagnetic compatibility - Testing and measurement techniques - Surge (Impact) immunity test "and GB/T 17626.11-2008" electromagnetic compatibility test and measurement technology voltage sags Drop, short interruptions and voltage variations immunity tests "basis.
This outline is the first release.
Dynamic (movable) ECG machine Type Evaluation Outline
1 Scope
This type of evaluation outline for the following two types of dynamic pattern evaluation (removable) ECG machine.
a) continuous recording, analysis and electrocardiogram achieve full playback. It may be recorded after storage back to the stand-alone workstation Caving or recorded, analyzed simultaneously.
b) continuous analysis but only a part of the record, does not provide full playback.
2. References
This outline references the following documents.
JJG1042-2008 dynamic (movable) ECG machine GB/T 14710-2009 medical electrical environmental requirements and test methods GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test GB/T 17626.11-2008 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage Variations immunity tests these documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents Members, release date only applies to this outline, however, encourage the parties according to research whether this outline agreement Use the latest versions of these files. For undated references, the latest edition (including all amendments ) Apply to this syllabus.
3 Overview
Dynamic (movable) ECG machine capable of continuously 24h or longer, three-channel recording in the patient's natural state or multi-channel ECG signal by means of a computer for display, analysis and processing, find all kinds of arrhythmia and ST events Segment abnormalities, provide an important basis for clinical diagnosis and treatment.
Dynamic (movable) ECG machine is usually divided into two types.
a) for continuous recording and analytical dynamic (movable) ECG machine
1) Conventional dynamic (movable) ECG machine, the first recorded ECG signal, and then dividing by the individual workstation Analysis process;
2) real-time dynamic (movable) ECG, recorded and analyzed simultaneously.
b) Continuous analysis but some recordable dynamic (movable) ECG machine
1) In the course of the entire ECG only on important events or specific ECG recording;
2) In the whole course of the real ECG recording ECG, but only generates time and amplitude compression formats
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
How to Download JJF 1392-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1392-2013
$525.00