JJF 1391-2013Program of Pattern Evaluation of Electrocardiograph (English PDF)
心电图机型式评价大纲
This is a limited preview
Buy now to download the full PDF (25 pages)
Need quotation for your management?
Get a formal quotation for JJF 1391-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
February 16, 2013
Implementation date
May 16, 2013
Scope
JJF 1391-2013 is the English-translated version of 心电图机型式评价大纲.
JJF 1391-2013 is the Chinese standard "Program of Pattern Evaluation of Electrocardiograph". Issued on 2013-02-16, in force from 2013-05-16.
Found what you need?
Document preview — JJF 1391-2013
National Standard of the People's Republic of China
- ICS
- 17.220
Contents
- Introduction (III)
- 1 Scope (1)
- 2. References (1)
- 3 Overview (1)
- 4 Legal management requirements (1)
- 4.1 Units of measurement requirements (1)
- 4.2 Legal metrology requirements for marking and identification of measuring instruments (2)
- 4.3 Other requirements (2)
- 5 Measurement requirements (2)
- 5.1 Calibration voltage (amplitude internal calibrator) (2)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Legal management requirements (1)
4.1 Units of measurement requirements (1)
4.2 Legal metrology requirements for marking and identification of measuring instruments (2)
4.3 Other requirements (2)
5 Measurement requirements (2)
5.1 Calibration voltage (amplitude internal calibrator) (2)
Voltage measurement 5.2 (2) Interval 5.3 (2)
5.4 GB (2)
5.5 Frequency Characteristics (2)
5.6 Resistance polarization voltage (2)
5.7 Noise (2)
5.8 Common-mode rejection ratio (2)
5.9 the sensitivity (gain) (2) Recording speed 5.10 (3)
5.11 Record hysteresis (3)
5.12 Overshoot (3)
Time constant of 5.13 (3)
5.14 Base line width (3)
5.15 Baseline drift (3)
5.16 Input impedance (3)
6 General Requirements (3)
6.1 Appearance and working properly check (3)
6.2 Climate requirements (3)
6.3 Mechanical environmental requirements (3)
6.4 Power adaptability (3)
6.5 EMC requirements (3)
7 Type evaluation item list (4)
8 Pilot projects test methods and conditions (5)
8.1 Legal Requirements Management (5)
8.2 Metrological requirements (5)
8.3, and appearance check work (14)
8.4 Climate Environmental Testing (14)
8.5 Mechanical environmental testing (15)
8.6 Power adaptability test (16)
8.7 Electromagnetic compatibility tests (16)
9 Type, Judgment principle (24) Results
Appendix A simulation model electrocardiogram evaluation formula original record format (25)
Introduction
This outline is simulated ECG machine type evaluation basis.
The preparation of the outline to JJG543-2008 "ECG", GB/T 14710-2009 "Medical Electrical Environment Requirements and test methods ", GB/T 17626.2-2006" Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity Test ", GB/T 17626.4-2008" Electromagnetic compatibility Testing and measurement techniques - Electrical fast transient burst immunity Test ", GB/T 17626.5-2008" Electromagnetic compatibility test and measurement technology surge (impact) immunity test Test "and GB/T 17626.11-2008" electromagnetic compatibility test and measurement techniques - Voltage dips, short interruptions and Voltage variations immunity tests "basis.
This outline is the first release.
ECG machine type evaluation outline
1 Scope
This type of evaluation framework for real-time measurement of body surface potential cardiac analog single-channel, multi-channel electrocardiograph the pattern evaluation.
2. References
This outline references the following documents.
JJG543-2008 ECG
GB/T 14710-2009 medical electrical environmental requirements and test methods GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test GB/T 17626.11-2008 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage Variations immunity tests these documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents Members, release date only applies to this outline, however, encourage the parties according to research whether this outline agreement Use the latest versions of these files. For undated references, the latest edition (including all amendments ) Apply to this syllabus.
3 Overview
ECG tracings is heart tissue activity of biological signals generated by the instruments for clinical diagnosis and for medical Biological wave, which is mainly composed of an input circuit, amplifiers and recorders and other components, divided into single-channel ECG and multi-channel electrocardiograph. Single Channel ECG electrocardiogram by the way is an analog linear amplifier and recorder composition Machine; multi-channel ECG machine is a multi-channel linear amplifier and an analog recording device consisting of ECG machine.
Block diagram of Figure 1 ECG machine 4 legal management requirements 4.1 units of measurement requirements
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
How to Download JJF 1391-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1391-2013
$525.00