JJF 1387-2013Calibration Specification for Vectorscopes (English PDF)
矢量示波器校准规范
This is a limited preview
Buy now to download the full PDF (21 pages)
Need quotation for your management?
Get a formal quotation for JJF 1387-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 6, 2013
Implementation date
April 6, 2013
Scope
JJF 1387-2013 is the English-translated version of 矢量示波器校准规范.
JJF 1387-2013 is the Chinese standard "Calibration Specification for Vectorscopes". Issued on 2013-01-06, in force from 2013-04-06.
Found what you need?
Document preview — JJF 1387-2013
National Standard of the People's Republic of China
- ICS
- 17.220
Contents
- Introduction (III)
- 1 Scope (1)
- 2. References (1)
- 3 Terminology and units of measurement (1)
- 3.1 SCH phase (1)
- 3.2 Crosstalk between channels (1)
- 4 Overview (1)
- 5 Metrological characteristics (1)
- 5.1 Chrominance bandwidth (1)
- 5.2 Vector phase (1)
- 5.3 Vector phase increment (1)
- 5.4 Vector Magnitude (2)
- 5.5 Differential gain (2)
- 5.6 Differential Phase (2)
- 5.7 SCH phase (2)
- 5.8 Variable gain adjustment range (2)
- 5.9 Return Loss (2)
- 5.10 Carrier frequency offset changes the phase (2)
- 5.11 Burst amplitude change of phase offset (2)
1 Scope (1)
2 References (1)
3 Terminology and units of measurement (1)
3.1 SCH phase (1)
3.2 Crosstalk between channels (1)
4 Overview (1)
5 Metrological characteristics (1)
5.1 Chrominance bandwidth (1)
5.2 Vector phase (1)
5.3 Vector phase increment (1)
5.4 Vector Magnitude (2)
5.5 Differential gain (2)
5.6 Differential Phase (2)
5.7 SCH phase (2)
5.8 Variable gain adjustment range (2)
5.9 Return Loss (2)
5.10 Carrier frequency offset changes the phase (2)
5.11 Burst amplitude change of phase offset (2)
Channel crosstalk between 5.12 (2)
5.13 XY channel (2)
Calibration Condition 6 (2)
6.1 Environmental conditions (2)
6.2 Calibration equipment (2)
7 Calibration methods and calibration items (4)
7.1 Appearance and working properly check (4)
7.2 Chrominance bandwidth (4)
Vector phase 7.3 (5)
7.4 Vector phase increment (5)
7.5 Vector Magnitude (6)
7.6 Differential gain and differential phase (6)
7.7 SCH phase (6)
7.8 Variable gain adjustment range (6)
7.9 Return Loss (7)
7.10 Carrier frequency offset changes the phase (7)
7.11 Burst amplitude change phase shift (7)
7.12 Crosstalk between the channels (7)
7.13 XY channel frequency response (8)
7.14 XY phase measurement (8)
8 Calibration results expression (8)
9 Recalibration interval (9)
Appendix A Calibration Record Form (10)
Appendix B major project calibration Measurement Uncertainty instance (16)
Appendix C calibration results within the page format (19)
Introduction
This specification based JJF 1071-2010 "National Calibration Specifications writing rules" and JJF 1059-1999 "measure Evaluation and Expression of Uncertainty "Writing. Specification uses the GB 3174-1995 "PAL-D television broadcasting system specification" Related definition color bar signal and the representation and GB/T 7400-2011 "Broadcasting term" in the derivative gain and the definition of differential phase. Measuring the PAL television signal vector oscilloscope calibration method are described.
This specification is the first release.
Vectorscope calibration specifications
1 Scope
This standard applies to the PAL vectorscope calibration, the calibration of the NTSC vectorscope can refer carried out.
2. References
GB 3174-1995 PAL-D television broadcasting system specifications GB/T 7400-2011 term Broadcasting for dated references, only the dated edition applies to this specification; undated references, the latest version (including any amendments) applies to this specification.
3 terminology and units of measurement
3.1 SCH phase subcarriertohorizontalphase TV video signal horizontal sync leading edge 50% level and a reference subcarrier over the timing relationship between the zero. The error in subcarrier phase in degrees.
3.2 channel crosstalk between crosstalkbetweenchannels A trace of the voltage signal generated at the output corresponding with the UAA A track signal corresponding to the output of the B track produced UAB than the input voltage of the string, expressed in decibels.
4 Overview
Vectorscope mainly used to measure and display analog TV video signal chrominance component vector of phase and amplitude, there these vectorscope also has differential gain, differential phase, SCH phase measurements and other functions. Vectorscope is analog video Frequency measuring instrument used and displayed. It mainly consists of the video amplifier, subcarrier generator, demodulators, phase shifters, sweep Description generator, output amplifier, a calibration signal generator, the election row controller, a display portion and other units.
5 Metrological characteristics
5.1 Chroma Bandwidth
5.1.1 Measuring range. 1MHz ~ 2MHz.
5.1.2 The maximum permissible error. ± 200kHz.
5.2 vector phase
5.2.1 Measuring range. 0 ° ~ 360 °.
5.2.2 The maximum permissible error. ± 1 °.
5.3 vector phase increment
5.3.1 Measuring range. ± 10 ° or ± 3 °.
5.3.2 The maximum permissible error. ± 0.5 °.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
How to Download JJF 1387-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
JJF 1387-2013
$435.00