JJF 1386-2013Calibration Specification for Medium Power Meters (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for JJF 1386-2013 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

JJF 1386-2013 (Calibration Specification for Medium Power Meters) is available as an English-translated PDF.

JJF 1386-2013 — This standard applies to the frequency range of 1 MHz ~ 40 GHz, power range of 0. 1 W ~ 500 W types of RF and microwave power meter calibration.

Found what you need?

Document preview — JJF 1386-2013

National Standard of the People's Republic of China

ICS
17.220
Classification
A 56

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metrological characteristics (1)
  • 4 Calibration conditions (1)
  • 4.1 Calibration of environmental conditions (1)
  • 4.2 Calibration Equipment (1)
  • 5 Calibration items and calibration methods (3)
  • 5.1 Appearance and working properly check (3)
  • 5.2 DC power calibration (3)
  • 5.3 Calibration factor/RF power calibration (5)
  • 5.4 Calibration voltage standing wave ratio (9)
  • 6 Calibration expression (10)
  • 7 Recalibration interval (10)
  • Appendix A Calibration record format (11)
  • Appendix B Calibration Certificate page format (13)
  • Appendix C Evaluation of Uncertainty in Measurement Examples (15)
  • Appendix D Where water load, power meter calibration (20)

1 Scope (1)

2 Overview (1)

3 Metrological characteristics (1)

4 Calibration conditions (1)

4.1 Calibration of environmental conditions (1)

4.2 Calibration Equipment (1)

5 Calibration items and calibration methods (3)

5.1 Appearance and working properly check (3)

5.2 DC power calibration (3)

5.3 Calibration factor/RF power calibration (5)

5.4 Calibration voltage standing wave ratio (9)

6 Calibration expression (10)

7 Recalibration interval (10)

Appendix A calibration record format (11)

Appendix B Calibration Certificate page format (13)

Appendix C Evaluation of Uncertainty in Measurement Examples (15)

Appendix D where water load, power meter calibration (20)

Introduction

This specification based JJF 1071-2010 "National Calibration Specifications writing rules" and JJF 1059-1999 "test Evaluation and Expression of Uncertainty "Writing. This specification was first released, mainly for the frequency range of 1MHz ~ 40GHz, power range from 0.1W ~ 500W by type and calibration method in which the power meter terminal were Regulation set. Calibration projects include. DC power or RF power calibration factor and voltage standing wave ratio. Given in the Appendix Measuring alternating comparison, the standard transfer method and direct method of measuring the power meter calibration factors Calibration Uncertainty Evaluation instance.

The power meter calibration specification

1 Scope

This specification applies to the calibration frequency range of 1MHz ~ 40GHz, power range from 0.1W ~ 500W each RF and microwave power meter calibration types.

2 Overview

The power meter is used to measure the power of the microwave signal equipment, access systems based on their different ways, can be divided through Through type and terminal type two types.

Meter usually consists of small directional coupler power meter and composed by the formula of power, the use of a directional coupler coupled adjacent portion of the arm Power, after detecting an indication of the magnitude of power through.

Wherein the terminal is a power meter can be used as a terminal load absorbed power, while indicating the magnitude of the power meter Device. Press measuring principle can be divided calorimeter where power meter, thermocouple type of power meter.

3 Metrological characteristics DC power range. 0.1W ~ 9W;

Calibration factor measurement uncertainty. 2.0% ~ 9% (k = 2);

VSWR. greater than 1.00.

Note. The above indicators are not used to determine eligibility for reference only.

4 calibration conditions

4.1 Calibration environmental conditions Ambient temperature. (23 ± 5) °C;

Relative humidity. less than 80%;

Power supply. voltage (220 ± 11) V, frequency (50 ± 1) Hz;

Other. around no effect mechanical vibration and electromagnetic interference calibration system to work.

4.2 Calibration Equipment Calibration equipment must be certified by the agency and are subject to legal metrology within the validity period, or registered calibrated real Calibration laboratories, and within the recommended recalibration interval specified by the user.

Major equipment calibration as follows.

4.2.1 Signal Generator Frequency range. 1MHz ~ 40GHz;

Frequency stability. better than 1 × 10-6/5min;

Amplitude stability. better than 0.01dB/5min;

Output power range. -70dBm ~ 20dBm.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

How to Download JJF 1386-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1386-2013

$375.00