JJF 1382-2012Program of Pattern Evaluation of Flourescence Spectrophotometers (English PDF)

荧光分光光度计型式评价大纲

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for JJF 1382-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

December 21, 2012

Implementation date

March 21, 2013

Scope

JJF 1382-2012 is the English-translated version of 荧光分光光度计型式评价大纲.

JJF 1382-2012 is the Chinese standard "Program of Pattern Evaluation of Flourescence Spectrophotometers". Issued on 2012-12-21, in force from 2013-03-21.

Found what you need?

Document preview — JJF 1382-2012

Contents

  • Introduction (III)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Overview (1)

1 Scope (1)

2 References (1)

3 Overview (1)

Technical information and test prototype unit 4 application should be submitted (1)

4.1 Technical Information (1)

4.2 Experimental prototype (1)

5 Legal management requirements (2)

5.1 Units of measurement requirements (2)

5.2 Accuracy requirements (2)

5.3 Legal metrology requirements for marking and identification of measuring instruments (2)

5.4 External structural design requirements (2)

5.5 Installation marking requirements (2)

6 Measurement requirements (2)

7 General technical requirements (3)

7.1 Appearance and initial inspection (3)

7.2 Insulation resistance test (3)

7.3 Dielectric strength test (3)

7.4 Adaptive power supply voltage (3)

7.5 High Temperature Test (3)

7.6 Low Temperature Test (3)

7.7 High temperature storage test (3)

7.8 Cryogenic storage test (3)

7.9 Damp heat test (3)

7.10 Crash Test (4)

7.11 Drop test (4)

8 Pattern evaluation item list (5)

9 Type evaluation test methods and conditions of the project (5)

9.1 Preparation before the test (5)

9.2 Appearance and initial inspection (5)

9.3 Insulation resistance test (6)

9.4 Dielectric strength test (6)

9.5 A Class monochromator wavelength indication error and repeatability (6) Class 9.6 B monochromator filter peak wavelength indication error test (8)

9.7 Sensitivity test (9)

9.8 Measurement linearity test (10)

9.9 Repeatability fluorescence spectrum peak intensity (11)

9.10 Stability test (11)

9.11 Working environment test (12)

9.12 Storage, transportation and environmental testing (14)

10 Determined the type of evaluation results (17)

Appendix A fluorescence spectrophotometer type evaluation original record format (18)

Introduction

This type of evaluation outline evaluation projects. Wavelength indication error, wavelength reproducibility, detection limit, measuring line , Fluorescence spectral peak intensity repetitive fluorescence intensity upper limit value shown in 10min drift and other technical indicators adopted JJG537-2006 "fluorescence spectrophotometer" metrics; within 10min zero line drift index using Industry Standard JB/T 5594-1991 "fluorescence spectrophotometer" in the index; increase the signal to noise ratio in the measurement of performance requirements, because Indicators for the different requirements of different manufacturers, which indicators to manufacturers declaration or instrument specification is based on indicators; in the pass Technical requirements increased dielectric strength, the power supply voltage and environmental adaptability of the pilot project, dielectric strength, power supply Pressure adaptation index using Industry Standard JB/T 5594-1991 "fluorescence spectrophotometer" in the index; Environmental Testing Mainly related to low temperature test, high temperature test, low temperature storage test, high temperature storage test, alternating hot and humid test, crash test Test, drop test and other projects, technical requirements and testing methods GB/T 11606-2007 "Environmental analysis instrument test Test method "in the relevant content.

This type of evaluation outline for the first release.

Fluorescence spectrophotometer type evaluation outline

1 Scope

This type of evaluation outline provides fluorescence spectrophotometer product classifications, requirements, test methods, and results processing Determine the rules for the new fluorescence spectrophotometer product type evaluation.

2. References

JJG537-2006 fluorescence spectrophotometer GB/T 11606-2007 analytical instruments environmental test methods JB/T 5594-1991 fluorescence spectrophotometer these documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this outline, however, the drum Reed whether the latest versions of these files according to the parties that this outline agreement. Those who do not note cited date Use, the latest versions apply to this outline.

3 Overview

Fluorescence spectrophotometer (hereinafter referred to as the instrument) from the light source system, excitation monochromator system, sample room, single launch Color system, the detector system and a data processing system structure. The light emitted by the light source, through the excitation monochromator becomes After the monochromatic light, according to the fluorescent substance on the test sample cell, thereby excite fluorescence emission monochromator is collected by Monochromator dispersion into monochromatic light, and fluorescence intensity was measured into an electrical signal by a detector system, the data processing system and converted into digital spectrum.

For a given material, the intensity of the excitation light and the wavelength is fixed, the fixed thickness of the liquid layer, the concentration of the solution at lower concentrations the fluorescence intensity F c and the fluorescent substance, the instrument constant k have the following relationship.

F = kc

According to this principle, a fluorescence spectrophotometer can be applied to the determination of the nature and amount of the fluorescent substance.

The instrument can be divided into two categories monochromator. A class is a dispersive monochromator, a class B filter monochromator.

Technical information and test prototype to be submitted by the applicant 4

4.1 Technical Information 4.1.1 the whole picture, assembly diagram, schematic diagram and major components.

4.1.2 Technical Standards Document (including test methods).

4.1.3 product manual.

Test report 4.1.4 manufacturing units or technical bodies prototype made.

4.2 Experimental Prototype the applicant can apply for a single product and to be filed by product. Where a single product by Shin Please, under normal circumstances should provide a prototype. By Series application products, each product extracted at least one-third

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

How to Download JJF 1382-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1382-2012

$465.00