JJF 1379-2012Calibration Specification of Thermistor Thermometers (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for JJF 1379-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

JJF 1379-2012 (Calibration Specification of Thermistor Thermometers) is available as an English-translated PDF.

JJF 1379-2012 — This standard applies to measurement range (-50 ~ +200)��C, the sensor is a thermistor thermometer calibration.

Found what you need?

Document preview — JJF 1379-2012

National Standard of the People's Republic of China

ICS
17.120
Classification
A 54
Replacing
JJG 363-1984; JJG 367-1984

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (III)
  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metrological characteristics (1)
  • 3.1 Insulation resistance (1)
  • 3.2 Indication error (1)
  • 3.3 Stability (2)

1 Scope (1)

2 Overview (1)

3 Metrological characteristics (1)

3.1 Insulation resistance (1)

3.2 Indication error (1)

3.3 Stability (2)

Calibration Condition 4 (2)

4.1 Environmental conditions (2)

4.2 Standard device and other ancillary equipment (2)

5 Calibration, inspection items and methods (2)

5.1 Calibration, inspection items (2)

5.2 Calibration, inspection method (3)

6 Calibration expression (4)

7 Recalibration interval (4)

Appendix A thermistor thermometer calibration record format (5)

Appendix B thermistor thermometer calibration certificate page format (7)

Appendix C thermistor thermometer to check the stability of the method (8)

Appendix D thermistor thermometer measuring indication error in a sample Evaluation of Uncertainty (9)

Appendix E thermistor thermometer measuring indication error Evaluation of Uncertainty Example Two (12)

Introduction

Based JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1059-1999 "Measurement Uncertainty Evaluation and Expression "and JJF 1001-2011" common measurement terms and definitions ", prepared a draft" thermistor thermometer school Standard Specification. " this specification replaces JJG367-1984 "grain temperature thermistor meter" and JJG363-1984 "semiconductor point thermometer." JJG367-1984 "thermistor food thermometer" by the National Measurement Bureau December 13, 1984 approved, in 1985 October 1 implementation. JJG363-1984 "semiconductor point thermometer" by the National Measurement Bureau in December 7, 1984 approved from December 1, 1985 into effect. Since the implementation of two regulations, it has not been revised.

The main technical specification changes are as follows.

--- Specification covers all levels of precision thermistor thermometer calibration;

--- Increased measurement uncertainty evaluation sample;

--- Introduction of stability inspection method in Appendix C;

--- Remove the sensor allows the provisions of errors.

Thermistor thermometer calibration specification

1 Scope

This standard applies to the measurement range (-50 ~ 200) °C, the sensor is a thermistor thermometer (hereinafter referred to as Thermometer) calibration.

2 Overview

Thermometer thermistor sensor and indicator composition. Its working principle is to use the thermistor resistance with temperature Variation and change characteristics of temperature measurement. It features fast response, low temperature sensing element, measured in the narrow zone the amount of accuracy.

3 Metrological characteristics

3.1 Insulation resistance at ambient temperature of 15 °C ~ 35 °C, relative humidity of 45% to 75%, each end of the thermometer display instrument Between the child, the insulation resistance between the sensor lead and its housing shall not be less than the requirements of Table 1.

Table 1 Insulation resistance Technical Requirements

No. Test Point

Insulation resistance Mohm 1 power supply - or housing 40 2 input terminals - or casing 20 3 input terminals - Power terminals 40 4 wire sensor - the sensor housing 20

3.2 Indication error Thermometer indication error following two representations.

3.2.1 directly measured value representation see equation (1).

delta = ± K (1)

Where.

delta --- Allow indication error, °C;

K --- indication error allowable limit, °C.

3.2.2 in order to quantify the range and units and the measured values relating to representation see equation (2).

delta = ± (a% FS bd) (2) where.

delta --- Allow indication error, °C;

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

How to Download JJF 1379-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1379-2012

$434.00