JJF 1369-2012Program of Pattern Evaluation of Compressed Natural Gas Dispensers (English PDF)
This is a limited preview
Buy now to download the full PDF (27 pages)
Need quotation for your management?
Get a formal quotation for JJF 1369-2012 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
JJF 1369-2012 (Program of Pattern Evaluation of Compressed Natural Gas Dispensers) is available as an English-translated PDF.
JJF 1369-2012 — This standard applies to compressed natural gas filling machine (hereinafter referred to as dispensers) for type evaluation.
Found what you need?
Document preview — JJF 1369-2012
National Standard of the People's Republic of China
- ICS
- 17.120
- Classification
- A 53
- Replacing
- JJG 996-2005
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (III)
- 1 Scope (1)
- 2. References (1)
- 3 Terms (1)
- 4 Overview (2)
- 4.1 Structure (2)
- 4.2 Works (3)
- 5 Legal management requirements (3)
- 5.1 Units of measurement (3)
- 5.2 Marks, and logos (3)
- 5.3 Design of the external structure (4)
- 6 Metering performance requirements (4)
- 6.1 The maximum permissible error (4)
- 6.2 Repeatability (4)
- 6.3 Filling machine turndown ratio (4)
- 6.4 Minimum measured (4)
- 6.5 Amount Paid error (4)
- 7 General technical requirements (4)
- 7.1 Appearance, random file and main features (4)
- 7.2 Security features (6)
- 7.3 Environmental adaptability (6)
- 7.4 Durability Test (8)
- 8 Types of evaluation items (8)
1 Scope (1)
2 References (1)
3 Terms (1)
4 Overview (2)
4.1 Structure (2)
4.2 Works (3)
5 Legal management requirements (3)
5.1 Units of measurement (3)
5.2 Marks, and logos (3)
5.3 Design of the external structure (4)
6 Metering performance requirements (4)
6.1 The maximum permissible error (4)
6.2 Repeatability (4)
6.3 Filling machine turndown ratio (4)
6.4 Minimum measured (4)
6.5 Amount Paid error (4)
7 General technical requirements (4)
7.1 Appearance, random file and main features (4)
7.2 Security features (6)
7.3 Environmental adaptability (6)
7.4 Durability Test (8)
8 Types of evaluation items (8)
Test methods and test conditions 9 items (8)
9.1 Test conditions (8)
9.2 Legal Requirements management inspection (10)
9.3 Appearance of random files and check main features (10)
9.4 Safety performance test (11)
9.5 Metrological performance test (13)
9.6 Environmental adaptability test (16)
Durability Test 9.7 (21) Determination (22) 10 type of evaluation results
10.1 Single determination principle (22)
10.2 Comprehensive decision rules (22)
Appendix A mass Gas Flow Standard Device (23)
Appendix B Without limiting protection function dispenser (25)
Appendix C type evaluation original record format (26)
Appendix D to select the number of prototypes and products (34)
Introduction
This outline is based on the national standard GB/T 19237-2003 "car with compressed natural gas filling machine" and the international rule of law Metrology (OIML) International Recommendation R139.2007 (E) "vehicle compressed gaseous fuel measuring systems" (Com-pressedgaseousfuelmeasuringsystemsforvehicles) as a technical basis, combined with our filling machines Industry status quo, to JJG996-2005 "CNG refueling machine" A "type of evaluation items and test methods" Appendix Subject to revisions. With international recommendations on the main technical indicators, national equivalents.
The Memorandum and JJG996-2005 in A "type of evaluation items and test methods" Compared appendix, the main technical change of the following.
--- Increased by large, medium and small flow filling machine terminology;
--- Modify the nameplate of measuring instruments, increasing the minimum content to be measured;
--- Modified with a pressure limiting protection structure and working principle function filling machine;
--- Increase the structure and working principle without pressure limiting protection filling machine;
--- Increasing the flow of medium and small filling machine is the smallest measurement requirements;
--- Modify the voltage limiting protection pressure range;
--- Cancel the solenoid valve off test;
--- Modify the type evaluation test specification standard equipment;
--- Modify the quality of the Gas Flow Standard device parameters associated equipment;
--- An increase of non-reference conditions and reference conditions during pattern evaluation tests;
--- Modify the measurement accuracy test (flow range, data processing, etc.);
--- Modified test measured minimum number of measurements and data processing;
--- Modified durability test methods and requirements;
--- Modify the power adaptability test;
--- Modify the original record format type evaluation.
CNG filling machine type evaluation outline
1 Scope
This type of evaluation outline is applied to compressed natural gas filling machine (hereinafter referred to as filling machine) pattern evaluation.
2. References
GB 4943.1-2011 Safety of information technology equipment - Part 1. General requirements GB/T 17626.2 Electromagnetic compatibility Testing and measurement techniques - Electrostatic discharge immunity test GB/T 17626.3 electromagnetic compatibility test and measurement technology RFEMS test GB/T 17626.4 Electromagnetic compatibility Testing and measurement techniques - Electrical fast transient burst immunity test GB/T 17626.5 electromagnetic compatibility test and measurement technology surge (impact) immunity test GB/T 17626.11 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations Immunity Test GB 18047 CNG GB/T 19236 cars with compressed natural gas dispensing nozzles GB/T 19237 Automotive CNG refueling machine GB/T 2423.1 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold GB/T 2423.2 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat GB/T 2423.4 Environmental testing for electric and electronic products Part 2. Test methods - Test Db. alternating wet Thermal (12h 12h cycle) GB 50156 car design and construction of refueling stations OIMLR139.2007 (E) vehicle compressed gaseous fuel measuring systems (Compressedgaseousfuel measuringsystemsforvehicles) these documents contain provisions which through reference in this syllabus constitute provisions of this outline. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this outline. However, the drum Reed whether the latest versions of these files according to the parties that this outline agreement. Those who do not note cited date Use, the latest versions apply to this outline.
3 Terms
3.1 CNG refueling machine compressednaturalgas (CNG) dispenser CNG filling the gas container, with special equipment and devices such as metering and pricing. It comprises a mass Meter, electronic meter controller, quick disconnect valve, dispensing nozzles and the like.
3.2 meter electronic controller electroniccomputer Computing and control means filling machine. May receive transmitted flow meter signal and voltage limiting transmission to the sensor Pressure signal, according to pre-set and filling machine parameters for computing and processing; you can transfer data and display operation Make, and automatically determine and control the flow of gas.
Note. The electronic meter controller to achieve the main function indication indicator, zeroing, adjust function, indicating the amount paid functions.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.
How to Download JJF 1369-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1064-2024 — Calibration Specification for Coordinate Measuring Machines
JJF 1171-2024 — Calibration Specification for Temperature and Humidity Itinerant Detecting Instruments
Secure payment via Stripe
Payments accepted
JJF 1369-2012