Valid

JJF 1340-2012Calibration Specification for Vector Hydrophones in Frequency Range 20Hz to 2000 Hz (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for JJF 1340-2012 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

JJF 1340-2012 (Calibration Specification for Vector Hydrophones in Frequency Range 20Hz to 2000 Hz) is available as an English-translated PDF.

JJF 1340-2012 — This standard applies to atmospheric pressure within a frequency range of 20Hz ~ 2000Hz using vector hydrophone calibration.

Found what you need?

Document preview — JJF 1340-2012

National Standard of the People's Republic of China

ICS
17.140
Classification
A 59

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2. References (1)
  • 3 Terminology and units of measurement (1)
  • 3.1 Hydrophone (1)
  • 3.2 Vector hydrophone sound pressure sensitivity level (1)
  • 3.3 Hydrophone velocity sensitivity level (1)
  • 3.4 Vector acoustic pressure gradient hydrophone sensitivity level (2)
  • 3.5 Axial sensitivity asymmetry (2)
  • 3.6 Lateral inhibition ratio (2)
  • 4 Overview (2)
  • 5 Metrological characteristics (2)
  • 5.1 Sound pressure sensitivity level (2)
  • 5.2 Velocity sensitivity level (2)
  • 5.3 Sound pressure gradient sensitivity level (2)
  • 5.4 Vector - Sound pressure channel phase difference (2)

1 Scope (1)

2 References (1)

3 Terminology and units of measurement (1)

3.1 Hydrophone (1)

3.2 Vector hydrophone sound pressure sensitivity level (1)

3.3 Hydrophone velocity sensitivity level (1)

3.4 Vector acoustic pressure gradient hydrophone sensitivity level (2)

3.5 Axial sensitivity asymmetry (2)

3.6 Lateral inhibition ratio (2)

4 Overview (2)

5 Metrological characteristics (2)

5.1 Sound pressure sensitivity level (2)

5.2 Velocity sensitivity level (2)

5.3 Sound pressure gradient sensitivity level (2)

5.4 Vector - Sound pressure channel phase difference (2)

Directivity 5.5 (3)

6 Calibration conditions (3)

Environmental conditions 6.1 (3)

6.2 Standards and other measuring equipment (3)

7 Calibration items and calibration methods (4)

7.1 Calibration items (4)

7.2 Calibration method (4)

8 Calibration results expression (8)

8.1 Calibration Data Processing (8)

8.2 Calibration certificate (8)

8.3 Calibration measurement uncertainty (8)

9 Recalibration interval (8)

Appendix A calibration certificate (9)

Appendix B wave tube design requirements (13)

Appendix C sound pressure sensitivity level measurements Uncertainty Evaluation Example (14)

Introduction

This specification based JJF 1071-2010 "national measurement calibration specifications write rules" in preparation.

This specification reference to GB/T 4130-2000 "low-frequency acoustic hydrophone calibration method" prescribed acoustic hydrophone Pressure sensitivity secondary calibration methods.

20Hz ~ 2000Hz vector hydrophone calibration specification

1 Scope

This standard applies to atmospheric pressure, hydrophone within 20Hz ~ 2000Hz frequency range of the calibration.

2. References

This specification references the following documents.

JJF 1001-2011 common measurement terms and definitions JJF 1034-2005 acoustic measurement terminology and definitions JJF 1059-1999 Evaluation and Expression of Uncertainty in Measurement GB 3102.7-1993 Quantities and units of acoustics GB/T 3947-1996 Acoustics Terminology GB/T 4130-2000 low-frequency acoustic hydrophone calibration methods for dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement JJF 1001-2011, JJF 1034-2005, GB 3102.7-1993 and GB/T 3947-1996 defined and the following terms and definitions apply to this specification.

This specification uses quantities and units GB/T 3102.7-1993 requirements.

3.1 hydrophone vectorhydrophone Output voltage and particle velocity or sound pressure gradient hydrophone into a ratio, and its point of view of a cosine function similar Characteristic shape, and the frequency characteristics do not change with the change.

3.2 vector hydrophone sensitivity of sound pressure level (Mp) pressuresensitivitylevelofvectorhydrophone Vector hydrophone pressure sensitivity Mp square with the reference sound pressure sensitivity to the base 10 of the ratio of the square Mpref Multiplied by 10.

Note.

1 in decibels (dB).

2 Mpref = 1V/µPa.

3.3 hydrophone velocity sensitivity level (Mv) particlevelocitysensitivitylevelofvectorhydrophone Hydrophone sensitivity Mv square velocity and the reference velocity sensitivity Mvref than the square of the base 10 of Multiplied by 10.

Note.

1 in decibels (dB).

2 Mvref = 1V/(m · s-1).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

How to Download JJF 1340-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1340-2012

$504.00