JJF 1336-2012Program of Pattern Evaluation for Nonautomatic Weighing Instrument (Non-self-indicating Weighing Instruments) (English PDF)
This is a limited preview
Buy now to download the full PDF (29 pages)
Need quotation for your management?
Get a formal quotation for JJF 1336-2012 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
JJF 1336-2012 (Program of Pattern Evaluation for Nonautomatic Weighing Instrument (Non-self-indicating Weighing Instruments)) is available as an English-translated PDF.
JJF 1336-2012 — This standard applies to the management of state law and the general level of accuracy of the level of accuracy of the non-automatic scales (non-self-indicating weighing) the type evaluation.
Found what you need?
Document preview — JJF 1336-2012
National Standard of the People's Republic of China
- ICS
- 17.060
- Classification
- A 53
- Replacing
- JJG 555-1996
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Introduction (III)
- 1 Scope (1)
- 2. References (1)
- 3 Terms (1)
- 4 Overview (1)
- 5 Legal management requirements (1)
- 5.1 Units of measurement (1)
- 5.2 Accuracy class (1)
- 5.3 Legal metrology marking and labeling requirements of measuring instruments (2)
- 5.4 Structural design requirements (2)
- 5.5 Installation marking requirements (2)
- 5.6 Experimental Prototype offers (2)
- 5.7 Technical Information (2)
- 6 Measurement requirements (3)
- 6.1 Accuracy class division (3)
- 6.2 Verification scale (3)
- 6.3 Scales the maximum permissible error (3)
1 Scope (1)
2 References (1)
3 Terms (1)
4 Overview (1)
5 Legal management requirements (1)
5.1 Units of measurement (1)
5.2 Accuracy class (1)
5.3 Legal metrology marking and labeling requirements of measuring instruments (2)
5.4 Structural design requirements (2)
5.5 Installation marking requirements (2)
5.6 Experimental Prototype offers (2)
5.7 Technical Information (2)
6 Measurement requirements (3)
6.1 Accuracy class division (3)
6.2 Verification scale (3)
6.3 Scales the maximum permissible error (3)
Tolerance weighing result between 6.4 (3) 6.5 0.00 (4)
6.6 Identification of force (4)
6.7 Sensitivity (4)
Tilting 6.8 (4)
7 General technical requirements (4)
7.1 Applicability (4)
7.2 Preventing fraudulent use (4)
7.3 Indication of weighing results (4)
7.4 Indicating means (5)
7.5 Structural requirements (5)
8 Pattern evaluation item list (6)
Test conditions and test items 9 (7)
9.1 Test conditions (7)
Check the 9.2 legal management requirements (7)
9.3 General technical requirements for inspection (7)
9.4 Test performance measurement (7)
Determination (13) 10 type of evaluation results
10.1 Type evaluation decision rules (13) Results
Total 10.2 Type evaluation conclusions (14)
10.3 Type evaluation report format (14)
Appendix A pattern evaluation original record format (15)
Appendix B type evaluation report page format (33)
Introduction
JJF 1336-2012 "non-automatic scale (non-self-indicating scales) Type Evaluation Outline" Modify adopted OIMLR 76-1.2006 "Non-automatic weighing instruments Part 1 metrological and technical requirements" of international recommendations regarding non-self-indicating scales Regulations, taking the GB/T 335-2002 "non-self-indicating scale" relevant technical requirements of national standards of. Replace JJG555-1996 "non-automatic weighing general test procedures" relating to the non-self-indicating a predetermined scale. in Performed JJF 1016-2009 "appliance type evaluation outline guidelines for the preparation of measurement" provisions on the preparation of the format.
Non-automatic scales (non-self-indicating scale) pattern evaluation outline
1 Scope
This outline is applicable to States according to the management's level of accuracy and the general level of accuracy of the non-automatic scale (non-self Indicating scales) (hereinafter referred to as scales) of pattern evaluation.
2. References
JJG99-2006 weight
JJF 1181 metrological terminology and definitions GB/T 335-2002 non-self-indicating scales GB/T 14250 Weighing term OIMLR76-1.2006 Non-automatic weighing instruments Part 1 metrological and technical requirements (Non-automatic weighinginstruments-Part 1. Meatrologicalandtechnicalrequirement) for dated references, only the dated edition applies to this outline; undated reference documents Member, the latest edition (including any amendments) applies to this outline.
3 Terms
The term of this syllabus and JJF 1181 "metrological terminology and definitions" and GB/T 14250 "Weighing the term "consistent terminology.
4 Overview
Non-self-indicating scale is based on the principle of the lever balance designed entirely by personnel to operate the machine to obtain the equilibrium position Scales that increase or decrease by increasing the mound and (or) Amusement mound move on the scale to balance the weight of the measured object, by metering bars Swing rod to determine the state of equilibrium, so as to obtain the weighing indication. Non-self-indicating scales include a variety of mechanical lever Scales, such as mobile text scales,, fixed floor scale, to the scale and so on.
5 legal management requirements 5.1 units of measurement Units of measurement scales used should be legal units of measurement, including. grams (g), kilograms (kg) and tonne (t).
5.2 accuracy class
Scale accuracy classes and symbols are shown in Table 1.
Table 1 Accuracy class and symbol
Accuracy class symbol the level of accuracy the general level of accuracy
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 29 pages — is available in the English PDF.
How to Download JJF 1336-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1064-2024 — Calibration Specification for Coordinate Measuring Machines
JJF 1171-2024 — Calibration Specification for Temperature and Humidity Itinerant Detecting Instruments
Secure payment via Stripe
Payments accepted
JJF 1336-2012
$964.00