Valid

JJF 1261.18-2017Rules of Metrology Testing for Energy Efficiency of AC Contactors (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for JJF 1261.18-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

September 26, 2017

Implementation date

March 26, 2018

Scope

JJF 1261.18-2017 (Rules of Metrology Testing for Energy Efficiency of AC Contactors) is available as an English-translated PDF.

JJF 1261.18-2017 — This standard specifies the direct-acting, three-electro-mechanical, and control-loop input power sources with a rated frequency of 50 Hz, a rated operating voltage of 380V (400V) and a rated operating current of 6A to 630A as the AC integral contactor.

Energy efficiency measurement requirements, metrology testing procedures, metrology testing methods, criteria for the assessment of measurement results, and test reports.

This standard does not apply to additional contactors and semiconductor contactors (solid state contactors) for power saving devices, household and similar applications.

This standard is applicable to the measurement and supervision of energy efficiency measurement of AC contactors. Commissioned inspections can refer to this standard.

Units that produce and sell AC contactor products can also be tested against this standard.

Found what you need?

Document preview — JJF 1261.18-2017

National Standard of the People's Republic of China

ICS
17.020
Classification
A 50
Replacing
JJF 1261.18-2015

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Introduction (II)
  • 1 Scope (1)
  • 2 References (1)
  • 3 Terms and units of measure (1)
  • 3.1 Suction power (1)
  • 3.2 AC contactor energy efficiency limit (1)
  • 3.3 Energy efficiency rating (1)
  • 4 Overview (1)
  • 5 Metrological requirements (2)
  • 5.1 Energy Efficiency Labelling (2)
  • 5.2 Suction power (2)
  • 5.3 Energy efficiency rating (2)
  • 6 Testing conditions (3)
  • 6.1 Environmental Conditions (3)
  • 6.2 Testing Equipment (3)
  • 6.3 Measurement uncertainty (3)
  • 7 Testing Items and Methods (3)
  • 7.1 Sampling Principles and Methods (3)
  • 7.2 Sample Testing (4)
  • 7.3 Original Records (5)
  • 7.4 Data Processing (5)
  • 8 Test Results (5)
  • 8.1 Eligibility Criteria for Holding Power Measurement Results (5)
  • 8.2 Test results assessment criteria (5)
  • 8.3 Test Report (6)
  • Appendix A Example of Evaluation of Measurement Uncertainty of AC Contactor Suction Power Measurement (7)
  • Appendix B AC Energy Contactor Energy Efficiency Measurement Inspection Sample Sheet (Format) (9)
  • Appendix C Original records of AC contactor energy efficiency metering (format) (11)
  • Appendix D AC Contactor Energy Efficiency Measurement Test Report (Format) (14)

1 Scope (1)

2 References (1)

3 Terms and units of measure (1)

3.1 Suction power (1)

3.2 AC contactor energy efficiency limit (1)

3.3 Energy efficiency rating (1)

4 Overview (1)

5 Metrological requirements (2)

5.1 Energy Efficiency Labelling (2)

5.2 Suction power (2)

5.3 Energy efficiency rating (2)

6 Testing conditions (3)

6.1 Environmental Conditions (3)

6.2 Testing Equipment (3)

6.3 Measurement uncertainty (3)

7 Testing Items and Methods (3)

7.1 Sampling Principles and Methods (3)

7.2 Sample Testing (4)

7.3 Original Records (5)

7.4 Data Processing (5)

8 Test Results (5)

8.1 Eligibility Criteria for Holding Power Measurement Results (5)

8.2 Test results assessment criteria (5)

8.3 Test Report (6)

Appendix A Example of Evaluation of Measurement Uncertainty of AC Contactor Suction Power Measurement (7)

Appendix B AC Energy Contactor Energy Efficiency Measurement Inspection Sample Sheet (Format) (9)

Appendix C Original records of AC contactor energy efficiency metering (format) (11)

Appendix D AC Contactor Energy Efficiency Measurement Test Report (Format) (14)

Introduction

In order to standardize the energy efficiency measurement and testing of AC contactors implementing energy efficiency labeling management, this specification is formulated in accordance with the requirements of JJF 1261.1-2017 "Energy Efficiency Measurement and Detection Rules for Energy-using Products".

This specification replaces JJF 1261.18-2015, compared with JJF 1261.18-2015, except for editorial changes.

The main changes are as follows.

--- The name of the specification was changed from "Regulations for the measurement of AC contactor energy efficiency labels" to "AC contactor energy sources "Efficiency measurement detection rules";

--- "5.1 Energy efficiency labeling" adds "energy efficiency information code" and "energy efficiency 'leader' information" Etc.

--- The original record format and report format were modified accordingly (Appendix C, Appendix D) the previous versions of this specification were issued as follows.

---JJF 1261.18-2015.

AC contactor energy efficiency Metering detection rules

1 Scope

This specification specifies the rated frequency of 50Hz, rated operating voltage of 380V (400V), rated operating current 6A ~ 630A direct-acting, three-electromechanical, control circuit input power for the exchange of the overall AC contactor Energy efficiency measurement requirements, metrological testing procedures, metrology testing methods, criteria for the assessment of metrological test results, and test reports Say something.

This specification does not apply to additional energy-saving devices, household and similar contactors and semiconductor contactors (Solid State Connections) Toucher).

This specification applies to the measurement and supervision of the energy efficiency measurement of AC contactors. The commissioned inspection can be conducted with reference to this specification. Students Units that produce and sell AC contactor products may also be tested in accordance with this specification.

The AC contactor that is tested shall be the product that the manufacturer has passed the inspection, or it is imported and sold by the seller.

commodity.

2 references

This specification refers to the following documents.

JJF 1261.1-2017 Energy Product Energy Efficiency Measurement Inspection Rules GB/T 2829-2002 Periodic Inspection Count Sampling Procedures and Tables (Applicable to Inspection of Process Stability) GB 21518-2008 AC contactor energy efficiency limit and energy efficiency rating for dated references, only dated editions apply to this specification; all undated references the latest version (including all amendments) applies to this specification.

3 Terms and units of measure the following terms and units of measurement apply to this specification.

3.1 Holding power the AC contactor maintains its own apparent power consumption in the pull-in state, and the unit of measure is V·A.

3.2 AC contactor energy efficiency limit value minimumalowablevaluesofenergyefficiencyfor ACcontactors the maximum allowable value of the AC contactor holding power under the specified measurement conditions is V·A.

3.3 Energy efficiency grade energyefficiencygrades A grading method that expresses the difference in the energy efficiency of energy products, and is generally divided into several levels.

The highest energy efficiency.

4 Overview

AC contactors are energy-using products that implement energy efficiency label management. AC contactor is a type used to connect frequently the electrical equipments that pass and break the AC main circuit and the large-capacity control circuit mainly include a contact system, an electromagnetic mechanism, and an arc extinguishing device.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

How to Download JJF 1261.18-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1261.18-2017

$300.00