JJF 1173-2018Calibration Specification for Measuring Receivers (English PDF)
This is a limited preview
Buy now to download the full PDF (24 pages)
Need quotation for your management?
Get a formal quotation for JJF 1173-2018 in 30 minutes.
Issued by
State Administration for Market Regulation
Level / Type
National · Mandatory
Issue date
June 25, 2018
Implementation date
December 25, 2018
Scope
JJF 1173-2018 (Calibration Specification for Measuring Receivers) is available as an English-translated PDF.
JJF 1173-2018 — This standard applies to the calibration of measurement receivers with a frequency range of 100 kHz to 50 GHz.
Found what you need?
Document preview — JJF 1173-2018
National Standard of the People's Republic of China
- ICS
- 17.220.01
- Classification
- A 56
- Replacing
- JJF 1173-2007
Issued by: State Administration for Market Regulation
Contents
- Introduction (II)
- 1 Scope (1)
- 2 Overview (1)
- 3 Measurement characteristics (1)
- 3.1 Output Reference Frequency (1)
- 3.2 Frequency measurement (1)
- 3.3 Tuning Level (1)
- 3.4 Frequency Modulation, Phase Modulation (1)
- 3.5 Amplitude modulation (1)
- 4 Calibration conditions (2)
- 4.1 Environmental conditions (2)
- 4.2 Measurement standards and other equipment (2)
- 5 Calibration items and calibration methods (3)
- 5.1 Calibration Project (3)
- 5.2 Appearance and normality check (4)
- 5.3 Output Reference Frequency (4)
- 5.4 Frequency Measurement (4)
- 5.5 Tuning Level (4)
- 5.6 Frequency Modulation, Phase Modulation (6)
- 5.7 Amplitude modulation (8)
- 6 Calibration result expression (10)
- 7 Re-study interval (11)
- Appendix A Original Record Format (12)
- Appendix B Calibration Certificate Page Format (15)
- Appendix C Example of Uncertainty Evaluation (18)
- Appendix D Bessel function zero value method FM frequency offset (31)
1 Scope (1)
2 Overview (1)
3 Measurement characteristics (1)
3.1 Output Reference Frequency (1)
3.2 Frequency measurement (1)
3.3 Tuning Level (1)
3.4 Frequency Modulation, Phase Modulation (1)
3.5 Amplitude modulation (1)
4 Calibration conditions (2)
4.1 Environmental conditions (2)
4.2 Measurement standards and other equipment (2)
5 Calibration items and calibration methods (3)
5.1 Calibration Project (3)
5.2 Appearance and normality check (4)
5.3 Output Reference Frequency (4)
5.4 Frequency Measurement (4)
5.5 Tuning Level (4)
5.6 Frequency Modulation, Phase Modulation (6)
5.7 Amplitude modulation (8)
6 Calibration result expression (10)
7 Re-study interval (11)
Appendix A Original Record Format (12)
Appendix B Calibration Certificate Page Format (15)
Appendix C Example of Uncertainty Evaluation (18)
Appendix D Bessel function zero value method FM frequency offset (31)
Introduction
This specification is based on JJF 1071-2010 "National Metrology Calibration Specification Writing Rules", related terms and measurements Uncertainty assessment follows JJF 1001-2011 "General Terms and Definitions" and JJF 1059.1-2012 Two documents of Uncertainty Evaluation and Representation.
This specification is a revision of the JJF 1173-2007 Measurement Receiver Calibration Specification. Relative to the original specification, this regulation the main technical changes of Fan are as follows.
1) Extend the carrier frequency range to 100 kHz to 50 GHz, and increase the frequency offset to 500 kHz.
Measurement performance requirements; calibration project increases output reference frequency, measurement; adjustment amplitude calibration increases attenuator calibration Quasi-law
2) Delete power calibration, FM frequency response and amplitude modulation frequency response calibration.
The release of previous versions of this specification.
---JJF 1173-2007.
Measurement receiver calibration specification
1 Scope
This specification applies to the calibration of measurement receivers in the frequency range from 100 kHz to 50 GHz.
2 Overview
The measurement receiver is an instrument used to measure weak signals. The measurement receivers covered by this specification are mainly used for RF/Microwave signal generator (with analog modulation function) and attenuator measurement, mainly by frequency, tuning level and modulation Component measurement and other functional modules, with frequency, tuning level, amplitude modulation, frequency offset and demodulation distortion the number of measurement functions.
3 Measurement characteristics
3.1 Output reference frequency 10MHz, the maximum allowable error. ± 1 × 10-9.
3.2 Frequency measurement
a) Frequency measurement range. 100kHz~50GHz;
b) Maximum allowable error. ± (1 × 10 -6 ~ 1 × 10-9).
3.3 tuning level
a) Tuning level range.
-120dB~0dB (100kHz~26.5GHz);
-110dB~0dB (26.5GHz~50GHz);
b) Maximum allowable error. ± (0.02dB~0.3dB).
3.4 Frequency modulation, phase modulation
a) FM frequency offset measurement range. 0kHz~500kHz; maximum allowable error. ±(1%~1.5%);
b) Phase modulation phase deviation measurement range. 0~500rad; maximum allowable error. ±(1%~4%);
c) demodulation distortion. <= 0.3%;
d) Remaining frequency modulation. <= 1 Hz (effective value);
e) Amplitude modulation suppression. <= 10Hz.
3.5 amplitude modulation
a) Measurement range of amplitude adjustment. 5%~99%;
b) Relative maximum allowable error. ± (0.5% ~ 1.5%);
c) demodulation distortion. <= 0.3%;
d) Remaining amplitude modulation. <=0.01% (effective value);
e) Frequency modulation suppression. <= 0.2%.
Note. The above technical indicators are not qualified for judgment and are only for reference.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
How to Download JJF 1173-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1173-2018