JJF 1172-2007Calibration Specification for Volatile Organic Compounds Photo Ionization Detectors (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (9 pages)

Need quotation for your management?

Get a formal quotation for JJF 1172-2007 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

February 28, 2007

Implementation date

May 28, 2007

Scope

JJF 1172-2007 (Calibration Specification for Volatile Organic Compounds Photo Ionization Detectors) is available as an English-translated PDF.

JJF 1172-2007 — This standard applies to monitoring air concentrations of volatile organic compounds VOCs photoionization detector calibration.

Found what you need?

Document preview — JJF 1172-2007

National Standard of the People's Republic of China

ICS
07.180.01
Classification
A 60

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • 1 Scope (1)
  • 2 Overview (1)
  • 3 Metrological characteristics (1)
  • 3.1 Measurement range (1)
  • 3.2 Indication error (1)
  • 3.3 Repeatability (1)
  • 3.4 Response Time (1)
  • 3.5 Drift (1)
  • 4 Calibration conditions (1)
  • 4.1 Environmental conditions (1)
  • 4.2 Standards and other equipment (2)
  • 5 Calibration items and calibration methods (2)
  • 5.1 Adjustment of the instrument (2)
  • 5.2 Indication error (2)
  • 5.3 Repeatability (3)
  • 5.4 Response Time (3)
  • 5.5 Drift (3)
  • 6 Calibration expression (3)
  • 7 Recalibration interval (4)
  • Appendix A VOC photoionization detector calibration records (5)
  • Appendix B Calibration certificate or calibration report calibration results content (6)
  • Appendix C Calibration uncertainty assessment (7)

1 Scope (1)

2 Overview (1)

3 Metrological characteristics (1)

3.1 Measurement range (1)

3.2 Indication error (1)

3.3 Repeatability (1)

3.4 Response Time (1)

3.5 Drift (1)

4 Calibration conditions (1)

4.1 Environmental conditions (1)

4.2 Standards and other equipment (2)

5 Calibration items and calibration methods (2)

5.1 Adjustment of the instrument (2)

5.2 Indication error (2)

5.3 Repeatability (3)

5.4 Response Time (3)

5.5 Drift (3)

6 Calibration expression (3)

7 Recalibration interval (4)

Appendix A VOC photoionization detector calibration records (5)

Appendix B calibration certificate or calibration report calibration results content (6)

Appendix C calibration uncertainty assessment (7)

VOC photoionization detector calibration specification

1 Scope

This specification is applicable to the detection of air (non-mine operating environment) VOC concentrations of volatile organic Compound photoionization detector calibration.

2 Overview

VOC photoionization detector (hereinafter referred to as the instrument) works. photoionization (PID) is the use of a 10.6eV (or 11.7eV) photon energy of the UV lamp as a light source, this high-energy UV radiation can make the air in almost all organic and inorganic ionization part, but still maintain the air basic ingredients N2, O2, CO2, H2O and CO, CH4 is not ionized (ionization potential of these substances is much higher than 10.6eV or 11.7eV), the test substance into the ionization chamber, by UV light exposure, the original stable molecular structure is ionized, producing Students positively charged ions and negatively charged electrons, under the influence of positive and negative electric field, weak current, a large current is detected formed Small, we can know the content of the substance in the air.

Instruments mainly by the sampling system, photoionization section and display components.

Unless know exactly what kind of gas is detected, the instrument detected concentration is generally displayed showing the detected all Total VOC content, expressed in VOC.

3 Metrological characteristics

3.1 Measuring range

Mole fraction X (VOC). 0 ~ 2000 × 10-6.

3.2 Indication error Tolerance limit. ± 10% FS.

3.3 Repeatability

The relative standard deviation should not exceed 3%.

3.4 Response Time

Response time <=20s.

3.5 Drift

3.5.1 Zero Drift

Instrument zero drift should not exceed one half of the allowed error limits.

3.5.2 Span drift

Instrument span drift should not exceed the tolerance limit of one-half.

Note. Due to calibrate the instrument and not only the instrument for determining eligibility or not, so that the above requirements are for reference only.

4 calibration conditions

4.1 Environmental conditions

4.1.1 Ambient temperature. (0 ~ 40) °C.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

How to Download JJF 1172-2007

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1172-2007

$175.00