JJF 1172-2007Calibration Specification for Volatile Organic Compounds Photo Ionization Detectors (English PDF)
This is a limited preview
Buy now to download the full PDF (9 pages)
Need quotation for your management?
Get a formal quotation for JJF 1172-2007 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Mandatory
Issue date
February 28, 2007
Implementation date
May 28, 2007
Scope
JJF 1172-2007 (Calibration Specification for Volatile Organic Compounds Photo Ionization Detectors) is available as an English-translated PDF.
JJF 1172-2007 — This standard applies to monitoring air concentrations of volatile organic compounds VOCs photoionization detector calibration.
Found what you need?
Document preview — JJF 1172-2007
National Standard of the People's Republic of China
- ICS
- 07.180.01
- Classification
- A 60
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- 1 Scope (1)
- 2 Overview (1)
- 3 Metrological characteristics (1)
- 3.1 Measurement range (1)
- 3.2 Indication error (1)
- 3.3 Repeatability (1)
- 3.4 Response Time (1)
- 3.5 Drift (1)
- 4 Calibration conditions (1)
- 4.1 Environmental conditions (1)
- 4.2 Standards and other equipment (2)
- 5 Calibration items and calibration methods (2)
- 5.1 Adjustment of the instrument (2)
- 5.2 Indication error (2)
- 5.3 Repeatability (3)
- 5.4 Response Time (3)
- 5.5 Drift (3)
- 6 Calibration expression (3)
- 7 Recalibration interval (4)
- Appendix A VOC photoionization detector calibration records (5)
- Appendix B Calibration certificate or calibration report calibration results content (6)
- Appendix C Calibration uncertainty assessment (7)
1 Scope (1)
2 Overview (1)
3 Metrological characteristics (1)
3.1 Measurement range (1)
3.2 Indication error (1)
3.3 Repeatability (1)
3.4 Response Time (1)
3.5 Drift (1)
4 Calibration conditions (1)
4.1 Environmental conditions (1)
4.2 Standards and other equipment (2)
5 Calibration items and calibration methods (2)
5.1 Adjustment of the instrument (2)
5.2 Indication error (2)
5.3 Repeatability (3)
5.4 Response Time (3)
5.5 Drift (3)
6 Calibration expression (3)
7 Recalibration interval (4)
Appendix A VOC photoionization detector calibration records (5)
Appendix B calibration certificate or calibration report calibration results content (6)
Appendix C calibration uncertainty assessment (7)
VOC photoionization detector calibration specification
1 Scope
This specification is applicable to the detection of air (non-mine operating environment) VOC concentrations of volatile organic Compound photoionization detector calibration.
2 Overview
VOC photoionization detector (hereinafter referred to as the instrument) works. photoionization (PID) is the use of a 10.6eV (or 11.7eV) photon energy of the UV lamp as a light source, this high-energy UV radiation can make the air in almost all organic and inorganic ionization part, but still maintain the air basic ingredients N2, O2, CO2, H2O and CO, CH4 is not ionized (ionization potential of these substances is much higher than 10.6eV or 11.7eV), the test substance into the ionization chamber, by UV light exposure, the original stable molecular structure is ionized, producing Students positively charged ions and negatively charged electrons, under the influence of positive and negative electric field, weak current, a large current is detected formed Small, we can know the content of the substance in the air.
Instruments mainly by the sampling system, photoionization section and display components.
Unless know exactly what kind of gas is detected, the instrument detected concentration is generally displayed showing the detected all Total VOC content, expressed in VOC.
3 Metrological characteristics
3.1 Measuring range
Mole fraction X (VOC). 0 ~ 2000 × 10-6.
3.2 Indication error Tolerance limit. ± 10% FS.
3.3 Repeatability
The relative standard deviation should not exceed 3%.
3.4 Response Time
Response time <=20s.
3.5 Drift
3.5.1 Zero Drift
Instrument zero drift should not exceed one half of the allowed error limits.
3.5.2 Span drift
Instrument span drift should not exceed the tolerance limit of one-half.
Note. Due to calibrate the instrument and not only the instrument for determining eligibility or not, so that the above requirements are for reference only.
4 calibration conditions
4.1 Environmental conditions
4.1.1 Ambient temperature. (0 ~ 40) °C.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
How to Download JJF 1172-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1172-2007
$175.00