JJF 1159-2006Calibration Specification for Quadrupole Inductively Coupled Plasma Mass Spectrometers (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for JJF 1159-2006 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine

Level / Type

National · Mandatory

Issue date

December 8, 2006

Implementation date

March 8, 2007

Scope

JJF 1159-2006 (Calibration Specification for Quadrupole Inductively Coupled Plasma Mass Spectrometers) is available as an English-translated PDF.

JJF 1159-2006 — This standard applies to quadrupole inductively coupled plasma mass spectrometer calibration of key performance indicators. Other types of inductively coupled plasma mass spectrometer calibration can be implemented by reference.

Found what you need?

Document preview — JJF 1159-2006

National Standard of the People's Republic of China

ICS
17
Classification
A 61

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • 1 Scope (1)
  • 2 Citations (1)
  • 3 Terms and units of measurement (1)
  • 3.1 Quality range (1)
  • 3.2 Resolution (1)
  • 3.3 Detection limit (1)
  • 3.4 Sensitivity (1)
  • 3.5 Abundance sensitivity (1)
  • 3.6 Background noise (2)
  • 3.7 Oxide ion yield (2)
  • 3.8 Double Charged Ion Yield (2)
  • 3.9 Quality stability (2)
  • 3.10 Flushing time (2)
  • 3.11 Isotope abundance ratio (2)
  • 3.12 Short-term stability (2)
  • 3.13 Long-term stability (2)
  • 4 Overview (2)
  • 4.1 Ion source (2)
  • 4.2 Quadrupole Mass Analyzer (2)
  • 4.3 Ion Detector (2)
  • 4.4 Computer System (3)
  • 4.5 Vacuum System (3)
  • 4.6 Power Supply System (3)
  • 5 Measurement characteristics (3)
  • 6 Calibration conditions (3)
  • 6.1 Laboratory environmental conditions (3)
  • 6.2 Standard materials and reagents for calibration (3)
  • 7 Calibration items and calibration methods (4)
  • 7.1 Visual inspection (4)
  • 7.2 Background noise calibration (4)
  • 7.3 Detection limit calibration (4)
  • 7.4 Sensitivity calibration (4)
  • 7.5 Abundance sensitivity calibration (4)
  • 7.6 Oxide ion yield calibration (5)
  • 7.7 Double Charge Ion Yield Calibration (5)
  • 7.8 Quality Stability Calibration (5)
  • 7.9 Resolution Calibration (5)
  • 7.10 Flushing time calibration (5)
  • 7.11 Isotope abundance ratio calibration (5)
  • 7.12 Short-term stability calibration (5)
  • 7.13 Long-term stability calibration (6)
  • 8 Calibration result expression (6)
  • 9 Re-study interval (6)
  • Appendix A Calibration Record Format (7)
  • Appendix B Calibration Certificate Format (10)

1 Scope (1)

2 Citations (1)

3 Terms and units of measurement (1)

3.1 Quality range (1)

3.2 Resolution (1)

3.3 Detection limit (1)

3.4 Sensitivity (1)

3.5 Abundance sensitivity (1)

3.6 Background noise (2)

3.7 Oxide ion yield (2)

3.8 Double Charged Ion Yield (2)

3.9 Quality stability (2)

3.10 Flushing time (2)

3.11 Isotope abundance ratio (2)

3.12 Short-term stability (2)

3.13 Long-term stability (2)

4 Overview (2)

4.1 Ion source (2)

4.2 Quadrupole Mass Analyzer (2)

4.3 Ion Detector (2)

4.4 Computer System (3)

4.5 Vacuum System (3)

4.6 Power Supply System (3)

5 Measurement characteristics (3)

6 Calibration conditions (3)

6.1 Laboratory environmental conditions (3)

6.2 Standard materials and reagents for calibration (3)

7 Calibration items and calibration methods (4)

7.1 Visual inspection (4)

7.2 Background noise calibration (4)

7.3 Detection limit calibration (4)

7.4 Sensitivity calibration (4)

7.5 Abundance sensitivity calibration (4)

7.6 Oxide ion yield calibration (5)

7.7 Double Charge Ion Yield Calibration (5)

7.8 Quality Stability Calibration (5)

7.9 Resolution Calibration (5)

7.10 Flushing time calibration (5)

7.11 Isotope abundance ratio calibration (5)

7.12 Short-term stability calibration (5)

7.13 Long-term stability calibration (6)

8 Calibration result expression (6)

9 Re-study interval (6)

Appendix A Calibration Record Format (7)

Appendix B Calibration Certificate Format (10)

Quadrupole Inductively Coupled Plasma Mass Spectrometer Calibration Specification

1 Scope of application this specification applies to the calibration of the main performance indicators of a quadrupole inductively coupled plasma mass spectrometer. Other types of electricity Calibration of the inductively coupled ion mass spectrometer can be performed with reference to the implementation.

2 Citations

JJF 1001-1998 General Terms and Definitions JJF 1059-1999 "Measurement and Expression of Measurement Uncertainty" JJF 1071-2000 "Rules for the Preparation of National Metrology Calibration Specifications" GB/T 15481-2000 "General requirements for testing and calibration laboratory capabilities" GB/T 6041-2002 General Principles of Mass Spectrometry Methods JJF 1120-2004 "Calibration Specification for Thermal Ionization Isotope Mass Spectrometer" Use of this specification should be done with the current valid version of the above cited documents.

3 terms and units of measure

3.1 Quality range

The mass range represents the mass interval of the element (isotope) that the mass spectrometer can measure, in atomic mass.

Unit u.

3.2 resolution

The resolution is expressed as the peak width at 10% of the peak height of an element, in units of u.

3.3 Detection limit

The minimum limit mass concentration of an element that can be measured by a mass spectrometer. The representation method is n of an element in a blank solution the mass concentration corresponding to the standard deviation of 3 times of the sub-measurement result. Unit ng·L-1.

3.4 Sensitivity

The signal response (count) obtained by the element concentration unit on the mass spectrometer detector, in units of Mcps/(mg·L-1).

3.5 Abundance sensitivity Abundance sensitivity characterizes a strong ion peak of mass M at the adjacent mass M 1 (or M-1) the effect of a front or trailing peak on an adjacent peak. Dimensionless. The abundance sensitivity is expressed by the following formula.

delta=IM 1IM

Or delta=IM-1IM

Where. delta---abundance sensitivity, dimensionless;

IM---mass is the signal intensity of M strong ion peak, cps;

IM-1---the tailing signal intensity of the ion peak of mass M at the mass M-1 position, cps;

IM 1---Tail signal strength at the mass M 1 position of the ion peak of mass M, cps.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

Referenced standards

How to Download JJF 1159-2006

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JJF 1159-2006

$444.00