JJF 1132-2005Calibration Specification for Combined Type Angle Rules (English PDF)
组合式角度尺校准规范
This is a limited preview
Buy now to download the full PDF (10 pages)
Need quotation for your management?
Get a formal quotation for JJF 1132-2005 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine released, This standard was approved by the General Administration of Quality Supervision, Inspection and Quarantine on April 28,.2005 and has been
Level / Type
National · Mandatory
Issue date
April 28, 2005
Implementation date
July 28, 2005
Scope
JJF 1132-2005 is the English-translated version of 组合式角度尺校准规范.
JJF 1132-2005 is the Chinese standard "Calibration Specification for Combined Type Angle Rules".
Found what you need?
Document preview — JJF 1132-2005
National Standard of the People's Republic of China
- ICS
- 17.040
Contents
- 1 Scope (1)
- 2 References (1)
- 3 Overview (1)
- 4 Measurement Characteristics (1)
- 4.1 Flatness or straightness of each measuring surface (1)
- 4.2 Ruler parallelism and indication error (2)
- 4.3 Protractor indication error (2)
- 4.4 Angular deviation of the angle (2)
- 4.5 Ruler measuring line and the central gauge angle coincidence degree (2)
- 5 Calibration conditions (2)
- 5.1 Environmental conditions (2)
- 5.2 Calibration standards and the corresponding equipment (2)
- 6 Calibration Items and Calibration Methods (2)
- 6.1 The flatness or straightness of each measuring surface (2)
- 6.2 Ruler parallelism and indication error (3)
- 6.3 Protractor indication error (3)
- 6.4 Angles of the angle of the angle deviation (3)
- 6.5 Ruler measuring line and center gauge bisector of coincidence (3)
- 7 Calibration Results Expression (4)
- 8 Re-school interval (4)
- Appendix A Special inspection cylinder technical requirements (5)
- Appendix B Combined Angle Gauge Measurement Results Uncertainty Analysis (6)
- Appendix C Calibration Certificate Internal Page Format (10)
1 Scope (1)
2 References (1)
3 Overview (1)
4 Measurement Characteristics (1)
4.1 Flatness or straightness of each measuring surface (1)
4.2 Ruler parallelism and indication error (2)
4.3 Protractor indication error (2)
4.4 Angular deviation of the angle (2)
4.5 Ruler measuring line and the central gauge angle coincidence degree (2)
5 Calibration conditions (2)
5.1 Environmental conditions (2)
5.2 Calibration standards and the corresponding equipment (2)
6 Calibration Items and Calibration Methods (2)
6.1 The flatness or straightness of each measuring surface (2)
6.2 Ruler parallelism and indication error (3)
6.3 Protractor indication error (3)
6.4 Angles of the angle of the angle deviation (3)
6.5 Ruler measuring line and center gauge bisector of coincidence (3)
7 Calibration Results Expression (4)
8 Re-school interval (4)
Appendix A special inspection cylinder technical requirements (5)
Appendix B Combined Angle Gauge Measurement Results Uncertainty Analysis (6)
Appendix C Calibration Certificate Internal Page Format (10)
Combined angle scale calibration specification
1 Scope
This standard applies to the dial measuring range of 0 ° ~ 180 °, sub-degree value of 1 °, ruler measuring range (0 ~
300) mm, dividing the value of 1mm modular angle scale calibration.
2 References
This specification cites the following documents.
JJG1-1999 steel ruler test procedures JJG33-2002 Universal angle foot test procedures General measurement terms and definitions Evaluation and Expression of Uncertainty in Measurement JJF 1094-2002 Measurement instrument characterization when using this specification, care should be taken to use the current valid version of the referenced offer.
3 Overview
Combined angle gauge by the angle ruler, ruler, center gauge, scale seat, sub-dial and other components, the structure shown in Figure 1 Show. Including the base, sub-dial, ruler can form protractor.
Figure 1 Schematic structure
1-center gauge; 2-foot holder; 3-indexing plate; 4-ruler; 5-angle foot;
Combination angle gauge is mainly used for machining, wood processing angle, length, height measurement and centering Bit and so on.
4 measurement characteristics 4.1 flatness or straightness of each measuring surface the measuring surface does not allow convex, ruler measuring surface straightness is not greater than 0.02mm, other measuring surface flatness
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.
How to Download JJF 1132-2005
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1132-2005
$195.00