JJF 1128-2004Calibration Specification for Vector Signal Analyzers (English PDF)
This is a limited preview
Buy now to download the full PDF (31 pages)
Need quotation for your management?
Get a formal quotation for JJF 1128-2004 in 30 minutes.
Issued by
The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 21,.2004, and
Level / Type
National · Mandatory
Issue date
September 21, 2004
Implementation date
December 21, 2004
Scope
JJF 1128-2004 (Calibration Specification for Vector Signal Analyzers) is available as an English-translated PDF.
JJF 1128-2004 — This standard applies to all types of vector signal analyzer calibration, also apply to digital communications test instrument calibration receiver section.
Found what you need?
Document preview — JJF 1128-2004
National Standard of the People's Republic of China
- ICS
- 17.220
- Classification
- A 56
Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on September 21,.2004, and
Contents
- 1 Scope (1)
- 2 Citations (1)
- 3 Terms and definitions (1)
- 3.1 Intermodulation distortion (1)
- 3.2 Vector Coordinates (1)
- 3.3 Error vector (1)
- 3.4 Error Vector Magnitude (1)
- 3.5 Vector amplitude error (1)
- 3.6 Phase error (2)
- 3.7 I/Q origin offset (2)
- 3.8 Frequency Offset (2)
- 4 Overview (2)
- 5 Measurement characteristics (2)
- 6 Calibration conditions (3)
- 6.1 Environmental conditions (3)
- 6.2 Standards and other equipment for calibration (4)
- 6.3 Other requirements (5)
- 7 Calibration items and calibration methods (5)
- 7.1 Work normality check (5)
- 7.2 Inspection of vector signal measurement function (6)
- 7.3 Inspection of I/Q signal measurement function (6)
- 7.4 Calibration of frequency measurement indication (6)
- 7.5 Calibration of carrier amplitude measurement indication (7)
- 7.6 Carrier amplitude measurement nonlinear calibration (8)
- 7.7 Calibration of two-channel measurement inconsistency (9)
- 7.8 Calibration of Input Channel Intermodulation Distortion (10)
- 7.9 Calibration of Input Channel Harmonic Distortion (10)
- 7.10 Calibration of Internal Noise of Input Channel (11)
- 7.11 Source to Channel Crosstalk Calibration (11)
- 7.12 Calibration of crosstalk between channels (12)
- 7.13 Calibration of input port return loss (12)
- 7.14 Calibration of source output return loss (13)
- 7.15 Calibration of signal source output amplitude (13)
- 7.16 Calibration of source harmonic distortion (13)
- 7.17 Calibration of measurement channel phase noise (14)
- 7.18 Calibration of digital measurement indications (14)
- 8 Expression of calibration results (15)
- 9 Re-study interval (16)
- Appendix A Vector Signal Analyzer Calibration Record Format (17)
- Appendix B Example of main project calibration uncertainty analysis (26)
1 Scope (1)
2 Citations (1)
3 Terms and definitions (1)
3.1 Intermodulation distortion (1)
3.2 Vector Coordinates (1)
3.3 Error vector (1)
3.4 Error Vector Magnitude (1)
3.5 Vector amplitude error (1)
3.6 Phase error (2)
3.7 I/Q origin offset (2)
3.8 Frequency Offset (2)
4 Overview (2)
5 Measurement characteristics (2)
6 Calibration conditions (3)
6.1 Environmental conditions (3)
6.2 Standards and other equipment for calibration (4)
6.3 Other requirements (5)
7 Calibration items and calibration methods (5)
7.1 Work normality check (5)
7.2 Inspection of vector signal measurement function (6)
7.3 Inspection of I/Q signal measurement function (6)
7.4 Calibration of frequency measurement indication (6)
7.5 Calibration of carrier amplitude measurement indication (7)
7.6 Carrier amplitude measurement nonlinear calibration (8)
7.7 Calibration of two-channel measurement inconsistency (9)
7.8 Calibration of Input Channel Intermodulation Distortion (10)
7.9 Calibration of Input Channel Harmonic Distortion (10)
7.10 Calibration of Internal Noise of Input Channel (11)
7.11 Source to Channel Crosstalk Calibration (11)
7.12 Calibration of crosstalk between channels (12)
7.13 Calibration of input port return loss (12)
7.14 Calibration of source output return loss (13)
7.15 Calibration of signal source output amplitude (13)
7.16 Calibration of source harmonic distortion (13)
7.17 Calibration of measurement channel phase noise (14)
7.18 Calibration of digital measurement indications (14)
8 Expression of calibration results (15)
9 Re-study interval (16)
Appendix A Vector Signal Analyzer Calibration Record Format (17)
Appendix B Example of main project calibration uncertainty analysis (26)
Vector Signal Analyzer Calibration Specification
1 Scope
This specification applies to the calibration of various types of vector signal analyzers, as well as to the digital communication integrated tester receiver unit.
Calibration of the points.
2 Citations
"MeasuringWaveformQuality, Code-DomainPower, TimeOfsetandPhaseOfsetofCDMA Signal", IEEE Instrumentation and Measurement Technology Conference, Brussels, Begium, June 4-6, 1996.
"OperationManualofModel89441AVectorSignalGenerator", 1997.
Handbook of Measurement and Testing Technology, Volume 8, Electronics, China Metrology Press, 1997.
3 Terms and definitions
3.1 Intermodulation Distortion. When a composite signal above two frequency components passes nonlinearity After the network, in addition to the original frequency components and their corresponding harmonic components in the output signal, each frequency is generated.
The sum and difference frequency components of the rate component, which are caused by the mutual modulation and the combined frequency components, are called mutual Adjust the distortion.
3.2 Vectordiagram. The number is represented by the corresponding point on the coordinate plane (I/Q plane) the instantaneous value of the modulated vector signal is called a graph (or state diagram), as shown in Figure 1. a plane represents a shape State, each point represents a vector. Different vectors represent a logical quantity of "0" or "1". Due to the nonlinearity of the RF amplifier with noise, interference and fading of the transmission channel, etc., the amplitude and phase of the vector change, so the measured vector the amount is not the same as the reference vector, as shown in Figure 2.
Figure 1 vector coordinate chart Figure 2 error vector
3.3 error vector. equal to the vector difference between the measured vector and the reference vector.
3.4 error vector magnitude (EVM). equal to the magnitude of the error vector. Usually expressed as the percentage of the peak of the reference vector.
3.5 vector magnitude error (vectormagnitudeerror). equal to the amplitude of the measured vector and the amplitude of the reference vector the difference between degrees. Usually expressed as a percentage of the peak of the reference vector.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 31 pages — is available in the English PDF.
How to Download JJF 1128-2004
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1128-2004
$505.00