JJF 1124-2004Calibration specification for Gear involute Measuring instruments (English PDF)
This is a limited preview
Buy now to download the full PDF (8 pages)
Need quotation for your management?
Get a formal quotation for JJF 1124-2004 in 30 minutes.
Issued by
The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on June 4,.2004, and
Level / Type
National · Mandatory
Issue date
June 4, 2004
Implementation date
December 1, 2004
Scope
JJF 1124-2004 (Calibration specification for Gear involute Measuring instruments) is available as an English-translated PDF.
JJF 1124-2004 — This standard applies to all kinds of gear measuring instruments involute measurement calibration, but does not include the home-tooth tester.
Found what you need?
Document preview — JJF 1124-2004
National Standard of the People's Republic of China
- ICS
- 17.040
- Classification
- A 52
- Replacing
- JJG 91-1989; JJG 93-1981
Issued by: The General Administration of Quality Supervision, Inspection and Quarantine issued, This specification was approved by the General Administration of Quality Supervision, Inspection and Quarantine on June 4,.2004, and
Contents
- 1 Scope (1)
- 2 Citations (1)
- 3 Overview (1)
- 3.1 Mechanical gear measuring instrument involute measurement principle (1)
- 3.2 Induction line measurement principle of numerical control gear measuring instrument (1)
- 4 Measurement characteristics (1)
- 4.1 Top and bottom coaxiality (1)
- 4.2 The indication error of the micrometric system (1)
- 4.3 Instrument tooth profile deviation (1)
- 4.4 Instrument tooth profile tilt deviation and its left and right tooth surface difference (1)
- 4.5 Instrument tooth profile total deviation and repeatability (1)
- 5 Calibration conditions (2)
- 5.1 Environmental conditions during calibration (2)
- 5.2 Calibration Standard (3)
- 5.3 Other requirements (3)
- 6 Calibration items (4)
- 7 Calibration method (4)
- 7.1 Coaxiality of the top and bottom axis (4)
- 7.2 Indication error of micrometric system (4)
- 7.3 Instrument tooth profile deviation (4)
- 8 Expression of calibration results (5)
- 9 Re-study interval (6)
- Appendix A Calibration Certificate Page Format (7)
1 Scope (1)
2 Citations (1)
3 Overview (1)
3.1 Mechanical gear measuring instrument involute measurement principle (1)
3.2 Induction line measurement principle of numerical control gear measuring instrument (1)
4 Measurement characteristics (1)
4.1 Top and bottom coaxiality (1)
4.2 The indication error of the micrometric system (1)
4.3 Instrument tooth profile deviation (1)
4.4 Instrument tooth profile tilt deviation and its left and right tooth surface difference (1)
4.5 Instrument tooth profile total deviation and repeatability (1)
5 Calibration conditions (2)
5.1 Environmental conditions during calibration (2)
5.2 Calibration Standard (3)
5.3 Other requirements (3)
6 Calibration items (4)
7 Calibration method (4)
7.1 Coaxiality of the top and bottom axis (4)
7.2 Indication error of micrometric system (4)
7.3 Instrument tooth profile deviation (4)
8 Expression of calibration results (5)
9 Re-study interval (6)
Appendix A Calibration Certificate Page Format (7)
Gear involute measuring instrument calibration specification this specification specifies calibration items and calibration methods for involute measurement of gear measuring instruments. When being measured by the gear when the instrument has multiple measurement functions, it should be used together with other specifications to fully evaluate the measurement of its different functions.
Sex.
1 Scope
This specification applies to the calibration of involute measurements of various gear measuring instruments, but does not include the upper profile inspection.
instrument.
2 Citations
This specification refers to the following documents.
JJF 1001-1998 General measurement terms and definitions JJF 1059-1999 Measurement Uncertainty Evaluation and Representation GB/T 10095.1-2001 Involute cylindrical gear precision - Part 1. Determining the deviation of the flanks Righteous allowable value Use of this specification should be done with the current valid version of the above cited documents.
3 Overview
Gear measuring instruments can be divided into mechanical and numerical control.
3.1 Mechanical gear measuring instrument involute measurement principle Mechanical gear measuring instruments are single disc type, grading disc type and lever disc type, etc. It is based on gear involute the principle of exhibition, the theoretical involute is generated by the mechanical mechanism, and the actual curve and theory of the device under test are opened by the sensor.
The line trajectory is compared, and the difference is input to the recorder to give an involute deviation curve. Its structure is shown in Figure 1.
3.2 Induction line measurement principle of numerical control gear measuring instrument the numerical control gear measuring instrument adopts the principle of coordinate measurement, through the angle measuring device (circular grating, etc.) and the length measuring device (long Grating, etc.) The coordinate position of the point on the actual curve of the device under test is measured, and compared with the theoretical curve of the involute, the involute is obtained.
Deviation curve. Its structure is shown in Figure 2.
4 Measurement characteristics 4.1 top and bottom coaxiality
4.2 The indication error of the micrometric system
4.3 Instrument tooth profile deviation
4.4 Instrument tooth profile tilt deviation and its left and right tooth surface differences
4.5 Instrument tooth profile total deviation and repeatability the above characteristics are listed in Table 1 for reference during calibration.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.
How to Download JJF 1124-2004
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 2425-2026 — Calibration specification for carbon dioxide incubators
JJF 1183-2025 — Calibration Specification for Temperature Transmitters
JJF 1282-2025 — Calibration Specification for Time Delay Relays
Secure payment via Stripe
Payments accepted
JJF 1124-2004
$135.00